REPUBLIC METALS INC
7930 JONES ROAD - PO BOX 605217, CLEVELAND, OH 44105 · NAICS 335931 Current-Carrying Wiring Device Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 29, 2016#341214203Jan 29, 2016Follow-Up (F) · Partial scope, Health#341214203$3,6962 viol.2 violations$3,696 in penalties
Inspection #341214203
Dates
- Opened
- Jan 29, 2016
- Closing Conference Date
- Jan 29, 2016
- Final Order
- Mar 31, 2016
- Closed
- Jan 16, 2018
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 17
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 repeat
- Initial Penalties
- $6,160
- Penalties on Record
- $3,696
- Site Address
- 7930 Jones Road, Cleveland, OH 44105
- Industry
- 331410 Nonferrous Metal (except Aluminum) Smelting and Refining
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 02001A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Repeat | 1 | 17 | $6,160 | $3,696 | Sep 6, 2016 | - | Mar 31, 2016 |
| 02001B | 1910.1025 Lead OSHA citation code: 19101025 E01 I | Repeat | 1 | 17 | $0 | $0 | Sep 6, 2016 | - | Mar 31, 2016 |
Jan 22, 2015#340201565Jan 22, 2015Complaint (B) · Partial scope, Safety#340201565$2,6403 viol.3 violations$2,640 in penalties
Inspection #340201565
Dates
- Opened
- Jan 22, 2015
- Closing Conference Date
- Mar 9, 2015
- Final Order
- Mar 26, 2015
- Closed
- Jan 12, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 12
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $4,400
- Penalties on Record
- $2,640
- Site Address
- 7930 Jones Road, Cleveland, OH 44105
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C01 | Serious | 2 | 1 | $2,800 | $1,680 | Mar 27, 2015 | - | Mar 26, 2015 |
| 01002A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C02 | Serious | 1 | 1 | $1,600 | $960 | Mar 27, 2015 | - | Mar 26, 2015 |
| 01002B | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C03 | Serious | 1 | 1 | $0 | $0 | Mar 27, 2015 | - | Mar 26, 2015 |
Aug 4, 2014#339881484Aug 4, 2014Complaint (B) · Partial scope, Health#339881484$13,40013 viol.13 violations$13,400 in penalties
Inspection #339881484
Dates
- Opened
- Aug 4, 2014
- Closing Conference Date
- Sep 29, 2014
- Final Order
- Dec 24, 2014
- Closed
- Oct 13, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 18
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 12 serious, 1 other-than-serious
- Initial Penalties
- $24,000
- Penalties on Record
- $13,400
- Site Address
- 7930 Jones Road, Cleveland, OH 44105
- Industry
- 331410 Nonferrous Metal (except Aluminum) Smelting and Refining
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (6 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G05 I | Serious | 1 | 18 | $2,000 | $1,000 | - | Dec 24, 2014 | |
| 01002 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 F01 | Other | 1 | 18 | $1,200 | $0 | Dec 22, 2014 | - | Dec 24, 2014 |
| 01004 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Serious | 2 | 18 | $2,000 | $1,000 | Dec 17, 2014 | - | Dec 24, 2014 |
| 01005 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 I | Serious | 1 | 18 | $2,000 | $1,000 | Mar 30, 2015 | - | Dec 24, 2014 |
| 01006A | 1910.1000 Air Contaminants OSHA citation code: 19101000 C | Serious | 1 | 18 | $2,400 | $2,300 | Oct 9, 2015 | - | Dec 24, 2014 |
| 01006B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 18 | $0 | $0 | Oct 9, 2015 | - | Dec 24, 2014 |
Showing the 6 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Aug 4, 2014#339881336Aug 4, 2014Complaint (B) · Complete scope, Safety#339881336$6,60011 viol.11 violations$6,600 in penalties
Inspection #339881336
Dates
- Opened
- Aug 4, 2014
- Closing Conference Date
- Oct 24, 2014
- Final Order
- Dec 24, 2014
- Closed
- Oct 13, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 18
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 8 serious, 3 other-than-serious
- Initial Penalties
- $13,200
- Penalties on Record
- $6,600
- Site Address
- 7930 Jones Road, Cleveland, OH 44105
- Industry
- 331410 Nonferrous Metal (except Aluminum) Smelting and Refining
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (6 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 5A0001 General Duty Clause, Section 5(a)(1) | Serious | 2 | 7 | $2,800 | $1,400 | Jan 11, 2015 | - | Dec 24, 2014 |
| 01002 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 A03 | Serious | 2 | 10 | $2,800 | $1,400 | Dec 17, 2014 | - | Dec 24, 2014 |
| 01003A | 1910.184 Slings OSHA citation code: 19100184 D | Serious | 3 | 7 | $2,400 | $1,200 | Dec 19, 2014 | - | Dec 24, 2014 |
| 01003B | 1910.184 Slings OSHA citation code: 19100184 I01 | Serious | 3 | 7 | $0 | $0 | Dec 17, 2014 | - | Dec 24, 2014 |
| 01003C | 1910.184 Slings OSHA citation code: 19100184 I09 III | Serious | 3 | 7 | $0 | $0 | Dec 17, 2014 | - | Dec 24, 2014 |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 2 | $1,600 | $800 | Jan 6, 2015 | - | Dec 24, 2014 |
Showing the 6 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 19, 2005#308513787Jan 19, 2005Referral (C) · Partial scope, Safety#308513787$7,00013 viol.13 violations$7,000 in penalties
Inspection #308513787
Dates
- Opened
- Jan 19, 2005
- Closing Conference Date
- Jan 19, 2005
- Closed
- May 23, 2006
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 15
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 13 serious
- Initial Penalties
- $12,750
- Penalties on Record
- $7,000
- Site Address
- 7930 Jones Road - Po Box 605217, Cleveland, OH 44105
- Industry
- 335931 Current-Carrying Wiring Device Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (6 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.110 Storage and Handling of Liquefied Petroleum Gases OSHA citation code: 19100110 E04 III | Serious | 1 | 10 | $750 | $400 | Mar 15, 2005 | - | - |
| 01002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G01 | Serious | 1 | 15 | $750 | $400 | Apr 12, 2005 | - | - |
| 01003 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L01 I | Serious | 1 | 6 | $1,000 | $600 | Apr 12, 2005 | - | - |
| 01004A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 3 | 6 | $1,250 | $800 | Apr 12, 2005 | - | - |
| 01004B | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A02 | Serious | 1 | 6 | $0 | $0 | Mar 23, 2005 | - | - |
| 01005A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H01 | Serious | 1 | 6 | $2,500 | $1,200 | Mar 23, 2005 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Dec 8, 2004#308470368Dec 8, 2004Planned (H) · Complete scope, Health#308470368$5,00011 viol.11 violations$5,000 in penalties
Inspection #308470368
Dates
- Opened
- Dec 8, 2004
- Closing Conference Date
- Dec 8, 2004
- Closed
- Jan 9, 2006
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 65
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 11 serious
- Initial Penalties
- $10,000
- Penalties on Record
- $5,000
- Site Address
- 7930 Jones Road - Po Box 605217, Cleveland, OH 44105
- Industry
- 335931 Current-Carrying Wiring Device Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 6 | 0.025 - 0.17 | mg/m³ |
Violations
Violation list (6 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 IA | Serious | 1 | 3 | $2,500 | $1,250 | Mar 23, 2005 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 III | Serious | 1 | 2 | $0 | $0 | Mar 23, 2005 | - | - |
| 01002A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Serious | 1 | 2 | $2,500 | $1,250 | Oct 1, 2005 | - | - |
| 01002B | 1910.1025 Lead OSHA citation code: 19101025 E01 I | Serious | 1 | 2 | $0 | $0 | Oct 1, 2005 | - | - |
| 01002C | 1910.1025 Lead OSHA citation code: 19101025 E03 IV | Serious | 1 | 15 | $0 | $0 | Mar 23, 2005 | - | - |
| 01002D | 1910.1025 Lead OSHA citation code: 19101025 E04 I | Serious | 1 | 4 | $0 | $0 | Jul 1, 2005 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jul 31, 1990#105926463Jul 31, 1990Follow-Up (F) · Partial scope, Health#105926463$3,06012 viol.12 violations$3,060 in penalties
Inspection #105926463
Dates
- Opened
- Jul 31, 1990
- Closing Conference Date
- Oct 31, 1990
- Contested
- Dec 10, 1990
- Final Order
- Feb 18, 1992
- Closed
- Feb 25, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 6 serious, 1 repeat, 5 other-than-serious
- Initial Penalties
- $4,800
- Penalties on Record
- $3,060
- Site Address
- 7930 Jones Road - Po Box 605217, Cleveland, OH 44105
- Industry
- 335931 Current-Carrying Wiring Device Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 2014P / 6A | 0 | mg/m³ |
| Arsenic, Inorganic | 1713P / 4A | 0 - 0.0057 | |
| Beryllium and Beryllium Compounds (as Be) | 2014P / 6A | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 2014P / 6A | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 2014P / 6A | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 2014P / 6A | 0 | mg/m³ |
| Copper Fume (as Cu) | 2014P / 6A | 0 - 0.0116 | mg/m³ |
| Iron Oxide Fume | 2014P / 6A | 0 - 0.059 | mg/m³ |
| Lead, Inorganic (as Pb) | 2014P / 6A | 0 - 0.1074 | mg/m³ |
| Manganese Fume (as Mn) | 2014P / 6A | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 2014P / 6A | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 2014P / 6A | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 2014P / 6A | 0 | mg/m³ |
| Zinc Oxide Fume | 2014P / 6A | 0 - 0.1785 | mg/m³ |
Violations
Violation list (6 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Other | 2 | 4 | $350 | $0 | Nov 18, 1990 | Dec 10, 1990 | Feb 18, 1992 |
| 01002A | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 K01 | Other | 1 | 1 | $490 | $0 | Nov 18, 1990 | Dec 10, 1990 | Feb 18, 1992 |
| 01002B | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L | Serious | 1 | 1 | $0 | $0 | Dec 7, 1990 | Dec 10, 1990 | Feb 18, 1992 |
| 01003 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 M12 | Serious | 1 | 2 | $420 | $420 | Nov 18, 1990 | Dec 10, 1990 | Feb 18, 1992 |
| 01004A | 1910.184 Slings OSHA citation code: 19100184 D | Other | 2 | 6 | $420 | $0 | Nov 18, 1990 | Dec 10, 1990 | Feb 18, 1992 |
| 01004B | 1910.184 Slings OSHA citation code: 19100184 I09 IV | Serious | 2 | 6 | $0 | $0 | Nov 18, 1990 | Dec 10, 1990 | Feb 18, 1992 |
Showing the 6 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Dec 17, 1987#103222139Dec 17, 1987Referral (C) · Partial scope, Health#103222139$3,62022 viol.22 violations$3,620 in penalties
Inspection #103222139
Dates
- Opened
- Dec 17, 1987
- Closing Conference Date
- Mar 28, 1988
- Contested
- Jun 3, 1988
- Final Order
- Dec 30, 1990
- Closed
- Feb 25, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 20
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 22
- Violation Types
- 12 serious, 2 willful, 8 other-than-serious
- Initial Penalties
- $19,620
- Penalties on Record
- $3,620
- Site Address
- 7930 Jones Road - Po Box 605217, Cleveland, OH 44105
- Industry
- 335931 Current-Carrying Wiring Device Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 3126P / 5A | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 3126P / 5A | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 3126P / 5A | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 3126P / 5A | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 3126P / 5A | 0 | mg/m³ |
| Copper Fume (as Cu) | 3126P / 5A | 0 - 0.0025 | mg/m³ |
| Iron Oxide Fume | 3126P / 5A | 0 - 0.0825 | mg/m³ |
| Lead, Inorganic (as Pb) | 3126P / 5A | 0 - 0.1401 | mg/m³ |
| Manganese Fume (as Mn) | 3126P / 5A | 0 - 0.0149 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 3126P / 5A | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 3126P / 5A | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 2826P / 2A | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 3126P / 5A | 0 | mg/m³ |
| Zinc Oxide Fume | 3126P / 5A | 0 - 0.5904 | mg/m³ |
Violations
Violation list (6 of 22 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001B | 1910.1025 Lead OSHA citation code: 19101025 F03 II | Serious | 1 | 20 | $0 | $50 | May 18, 1989 | Jun 3, 1988 | May 31, 1989 |
| 01001C | 1910.1025 Lead OSHA citation code: 19101025 F04 I | Serious | 1 | 20 | $0 | $0 | May 18, 1989 | Jun 3, 1988 | May 31, 1989 |
| 01002 | 1910.1025 Lead OSHA citation code: 19101025 E05 I | Serious | 1 | 20 | $640 | $220 | Jul 21, 1989 | Jun 3, 1988 | May 31, 1989 |
| 01003A | 1910.1025 Lead OSHA citation code: 19101025 G02 V | Serious | 1 | 20 | $640 | $220 | May 18, 1989 | Jun 3, 1988 | May 31, 1989 |
| 01003B | 1910.1025 Lead OSHA citation code: 19101025 G02 VII | Serious | 1 | 20 | $0 | $0 | May 18, 1989 | Jun 3, 1988 | May 31, 1989 |
| 01004 | 1910.1025 Lead OSHA citation code: 19101025 I01 | Serious | 1 | 20 | $640 | $220 | May 18, 1989 | Jun 3, 1988 | May 31, 1989 |
Showing the 6 violations listed first by citation identifier. This inspection has 22 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Failure to Abate Penalties3 citations, $7,360 in FTA penalties on record
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 3 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|
Showing the 0 FTA rows present in the first 6 citations on this inspection. OSHA's record shows 3 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
8 inspections, 1987 to 2016. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Electrical Equipment, Appliance, and Component Manufacturing, 4,532 employers with OSHA inspections. Arithmetic from DOL records.