This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a planned inspection of CHAS SVEC INC. at 5470 Dunham Rd., Maple Heights, OH 44137 on Jun 6, 2005. The inspection scope was complete. The case was closed on Mar 13, 2006.

OSHA documented 23 violations (10 serious, 13 other-than-serious) with total penalties on record of $4,000.

OSHA collected 24 air monitoring samples covering 1 substance during this inspection, including Silica, Crystalline Quartz (Respirable Fraction).

This employer has 1 other OSHA inspection on record at this establishment.

Inspection Details

Inspection Number
308734441
Type
Planned (H)
Scope
Complete
Opened
Jun 6, 2005
Closed
Mar 13, 2006
Total Violations
23
Penalties on Record
$4,000
Initial Penalties
$9,300
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Establishment

Address
5470 Dunham Rd., Maple Heights, OH 44137
Industry
327331 Concrete Block and Brick Manufacturing

Other Inspections of This Employer1 on record

Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed Mar 13, 2006.

Citations on Record
23

10 serious, 13 other-than-serious.

Initial Penalties
$9,300

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$4,000

Latest published amounts after changes in the enforcement process.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC80.0294 - 0.7417mg/m³
Sample WeightQC80.012 - 0.506mg
Silica, Crystalline Quartz (Respirable Fraction)80

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

CitationStandardTypeInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious$1,500$1,000Dec 15, 2005--
01002A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Serious$1,200$750Jan 31, 2006--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious$0$0Dec 15, 2005--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Other$3,000$0Jan 31, 2006--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious$1,200$750Dec 15, 2005--
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious$1,200$750Oct 17, 2005--
01007A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious$1,200$750Dec 15, 2005--
01007B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious$0$0Dec 15, 2005--
01007C1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious$0$0Dec 15, 2005--
01007D1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious$0$0Oct 17, 2005--
01007E1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious$0$0Dec 15, 2005--
020011904.32
Annual Summary
OSHA citation code: 19040032 A03
Other$0$0Oct 30, 2005--
020021910.23
Ladders
OSHA citation code: 19100023 A03
Other$0$0Oct 17, 2005--
020031910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 E04 III
Other$0$0Oct 17, 2005--
020041910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other$0$0Oct 30, 2005--
02005A1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other$0$0Oct 17, 2005--
02005B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other$0$0Oct 17, 2005--
02005C1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other$0$0Oct 30, 2005--
020061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other$0$0Oct 30, 2005--
020071910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Other$0$0Oct 17, 2005--
020081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other$0$0Oct 17, 2005--
020091910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIIA
Other$0$0Oct 30, 2005--
020101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other$0$0Oct 30, 2005--

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.