Skip to content
SafetyRecord logoSafetyRecord
ROCKY MOUNTAIN READY MIX CONCRETE INC.
$4,555
penalties
15
viol.
2
insp.

ROCKY MOUNTAIN READY MIX CONCRETE INC.

985 US HIGHWAY 85, BRIGHTON, CO 80603NAICS 327320 Ready-Mix Concrete Manufacturing

Inspections
2
Aug 2002 to May 2005 · 0 safety, 2 health
Violations
15
across 2 inspections
Penalties on record
$4,555
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 1Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 25, 2005Planned (H) · Complete scope, Health#308997238$2,2808 viol.

Inspection #308997238

Dates

Opened
May 25, 2005
Closing Conference Date
Jun 2, 2005
Closed
Aug 19, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
8
Violation Types
5 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$3,800
Penalties on Record
$2,280
Site Address
985 Us Highway 85, Brighton, CO 80603
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC10.1098mg/m³
Sample WeightQC10.08mg
Silica, Crystalline Quartz (Respirable Fraction)10%

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 E
Serious11$1,125$675Aug 17, 2005--
01001B1910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 F
Serious11$0$0Aug 17, 2005--
01001C1910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Serious11$0$0Aug 17, 2005--
010021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L02 II
Serious12$900$540Aug 17, 2005--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious11$1,575$945Aug 17, 2005--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Repeat11$200$120Aug 16, 2005--
030011910.134
Respiratory Protection
OSHA citation code: 19100134 K01
Other11$0$0Aug 17, 2005--
030021910.138
Hand Protection
OSHA citation code: 19100138 B
Other11$0$0Aug 2, 2005--
Aug 22, 2002Complaint (B) · Partial scope, Health#304980055$2,2757 viol.

Inspection #304980055

Dates

Opened
Aug 22, 2002
Closing Conference Date
Aug 27, 2002
Closed
Nov 15, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
7 other-than-serious
Initial Penalties
$3,150
Penalties on Record
$2,275
Site Address
975 Highway 85, Brighton, CO 80601
Industry
327320 Ready-Mix Concrete Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C
Other14$525$525Nov 20, 2002--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Other13$0$0Nov 6, 2002--
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F01
Other23$0$0Nov 6, 2002--
01001D1910.134
Respiratory Protection
OSHA citation code: 19100134 D01 III
Other14$0$0Nov 6, 2002--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other14$875$875Feb 6, 2003--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 E01
Other1-$875$0Oct 22, 2002--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 II
Other1-$875$875Oct 22, 2002--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection6 citations · $645
1910.24Step Bolts and Manhole Steps3 citations · $675
1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $875

Chemical exposure sampling

Samples
3
Substances
3
Inspections
1

Industry comparison

Violations per inspection
This employer7.5
Industry average3.3
Penalties per inspection
This employer$2,278
Industry average$2,364

Nonmetallic Mineral Product Manufacturing, 17,265 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: ready-mix concrete manufacturing reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 11.0%; NAICS 32732 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in BRIGHTON, CO