Skip to content
SafetyRecord logoSafetyRecord
CERAMIC FIBER TECHNOLOGIES, INC.
$3,561
penalties
31
viol.
5
insp.

CERAMIC FIBER TECHNOLOGIES, INC.

ROUTE 119 NORTH, MOUNT BRADDOCK, PA 15465NAICS 332323 Ornamental and Architectural Metal Work Manufacturing

Inspections
5
Oct 1997 to Sep 2009 · 1 safety, 4 health
Violations
31
across 5 inspections
Penalties on record
$3,561
latest amounts in DOL records
By classification
Serious 26Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 8, 2009Planned (H) · No Inspection scope, Health#312631732$00 viol.

Inspection #312631732

Dates

Opened
Sep 8, 2009
Closing Conference Date
Sep 8, 2009
Closed
Sep 9, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
126 Development Drive, Mount Braddock, PA 15465
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 23, 2006Follow-Up (F) · Partial scope, Health#310286489$00 viol.

Inspection #310286489

Dates

Opened
Aug 23, 2006
Closing Conference Date
Aug 23, 2006
Closed
Aug 29, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
126 Development Drive, Mount Braddock, PA 15465
Industry
332312 Fabricated Structural Metal Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 5, 2006Complaint (B) · Partial scope, Health#309040038$1,52111 viol.

Inspection #309040038

Dates

Opened
Jan 5, 2006
Closing Conference Date
Jan 12, 2006
Closed
Aug 29, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
10 serious, 1 other-than-serious
Initial Penalties
$2,175
Penalties on Record
$1,521
Site Address
126 Development Drive, Mount Braddock, PA 15465
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)10mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium10mg/m³
Chromium, Metal and Insoluble Salts10mg/m³
Cobalt, Metal, Dust and Fume (as Co)10mg/m³
Copper Fume (as Cu)10.0177842mg/m³
Gravimetric DeterminationQC112.381mg/m³
Iron Oxide Fume10.8335664mg/m³
Lead, Inorganic (as Pb)10mg/m³
Manganese Fume (as Mn)10.127343mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)10mg/m³
Nickel, Metal and Insoluble compounds (as Ni)10mg/m³
Sample WeightQC13.77mg
Silica, Crystalline Quartz (Respirable Fraction)11.2%
Vanadium fume (as V2O5)10mg/m³
Zinc Oxide Fume10mg/m³

Violations

Violation list (10 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious12$525$368Apr 26, 2006--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious12$0$0Apr 26, 2006--
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious12$525$368Mar 27, 2006--
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious12$0$0Mar 27, 2006--
01002C1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious12$0$0Mar 27, 2006--
01002D1910.134
Respiratory Protection
OSHA citation code: 19100134 K03
Serious12$0$0Mar 27, 2006--
01003A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Serious12$300$210Mar 27, 2006--
01003B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M03
Serious11$0$0Feb 27, 2006--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious112$525$365Mar 27, 2006--
010051910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F01
Serious12$300$210Mar 27, 2006--

Showing the 10 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 5, 2006Complaint (B) · Partial scope, Safety#309038891$2,04019 viol.

Inspection #309038891

Dates

Opened
Jan 5, 2006
Closing Conference Date
Jan 25, 2006
Closed
Mar 1, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12
Related Activity
1 complaint

Violations and Penalties

Total Violations
19
Violation Types
16 serious, 3 other-than-serious
Initial Penalties
$2,925
Penalties on Record
$2,040
Site Address
126 Development Drive, Mount Braddock, PA 15465
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (10 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious11$300$205Feb 13, 2006--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious11$300$210Feb 28, 2006--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious11$0$0Feb 28, 2006--
01002C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious14$0$0Feb 28, 2006--
01002D1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious11$0$0Feb 3, 2006--
01003A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$300$210Feb 13, 2006--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$0$0Feb 13, 2006--
01003C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Feb 13, 2006--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious32$525$365Feb 13, 2006--
01005A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious14$300$210Jan 31, 2006--

Showing the 10 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 29, 1997Planned (H) · Complete scope, Health#300381837$01 viol.

Inspection #300381837

Dates

Opened
Oct 29, 1997
Closing Conference Date
Oct 29, 1997
Closed
Nov 13, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Route 119 North, Mount Braddock, PA 15465
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B04
Other13$0$0Nov 10, 1997--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection5 citations · $368
1910.147Control of Hazardous Energy (Lockout/Tagout)4 citations · $210
1910.219Mechanical Power-Transmission Apparatus3 citations · $210

Chemical exposure sampling

Samples
16
Substances
16
Inspections
1

Industry comparison

Violations per inspection
This employer6.2
Industry average3.3
Penalties per inspection
This employer$712
Industry average$2,308

Fabricated Metal Product Manufacturing, 47,284 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in MOUNT BRADDOCK, PA