Skip to content
SafetyRecord logoSafetyRecord
ACTION PACKAGING, INC.
$20,345
penalties
32
viol.
7
insp.

ACTION PACKAGING, INC.

270 SOUTH COLLEGE STREET, WASHINGTON, PA 15301NAICS 453998 All Other Miscellaneous Store Retailers (except Tobacco Stores)

Inspections
7
Jan 1982 to Feb 2015 · 6 safety, 1 health
Violations
32
across 7 inspections
Penalties on record
$20,345
latest amounts in DOL records
By classification
Serious 16Willful 0Repeat 1Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 4, 2015Planned (H) · Partial scope, Safety#340277870$1,5752 viol.

Inspection #340277870

Dates

Opened
Feb 4, 2015
Closing Conference Date
Feb 4, 2015
Final Order
Mar 20, 2015
Closed
Mar 6, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$2,100
Penalties on Record
$1,575
Site Address
2160 North Main Street, Washington, PA 15301
Industry
322211 Corrugated and Solid Fiber Box Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious22$2,100$1,575Mar 9, 2015-Mar 20, 2015
020011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 G06 VI C 8
Other11$0$0Apr 13, 2015-Mar 20, 2015
Jan 6, 2006Referral (C) · Partial scope, Safety#309042760$15,12013 viol.

Inspection #309042760

Dates

Opened
Jan 6, 2006
Closing Conference Date
Jan 11, 2006
Closed
Jan 30, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32
Related Activity
1 referral

Violations and Penalties

Total Violations
13
Violation Types
9 serious, 1 repeat, 3 other-than-serious
Initial Penalties
$21,600
Penalties on Record
$15,120
Site Address
2160 North Main Street, Washington, PA 15301
Industry
453998 All Other Miscellaneous Store Retailers (except Tobacco Stores)

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (7 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious16$3,000$2,100Mar 3, 2006--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious16$900$630Mar 3, 2006--
010041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 E01
Serious11$3,000$2,100Jan 17, 2006--
01005A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 E02 II
Serious11$3,000$2,100Jan 17, 2006--
01005B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 E02 I
Serious11$0$0Jan 17, 2006--
010061910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious35$1,500$1,050Mar 3, 2006--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious14$2,100$1,470Mar 3, 2006--

Showing the 7 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 10, 2003Referral (C) · Partial scope, Safety#305107492$3,5007 viol.

Inspection #305107492

Dates

Opened
Jan 10, 2003
Closing Conference Date
Jan 10, 2003
Closed
Apr 9, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32
Related Activity
1 referral

Violations and Penalties

Total Violations
7
Violation Types
4 serious, 3 other-than-serious
Initial Penalties
$5,000
Penalties on Record
$3,500
Site Address
2160 North Main Street, Washington, PA 15301
Industry
322211 Corrugated and Solid Fiber Box Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$2,500$1,750Apr 3, 2003--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious125$2,500$1,750Apr 3, 2003--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious125$0$0Apr 3, 2003--
01002C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious125$0$0Apr 3, 2003--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other14$0$0Apr 3, 2003--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Other125$0$0Apr 3, 2003--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Other14$0$0Apr 3, 2003--
Jun 14, 1988Referral (C) · Partial scope, Safety#100506542$01 viol.

Inspection #100506542

Dates

Opened
Jun 14, 1988
Closing Conference Date
Jun 14, 1988
Closed
Jul 19, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
270 College Street, Washington, PA 15301
Industry
453998 All Other Miscellaneous Store Retailers (except Tobacco Stores)

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other11$0$0Jul 12, 1988--
May 6, 1988Complaint (B) · Partial scope, Health#743732$04 viol.

Inspection #743732

Dates

Opened
May 6, 1988
Closing Conference Date
May 6, 1988
Closed
Sep 16, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
270 South College Street, Washington, PA 15301
Industry
453998 All Other Miscellaneous Store Retailers (except Tobacco Stores)

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other110$0$0Jul 1, 1988--
01002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other19$0$0Jul 18, 1988--
01002B1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other19$0$0Jul 18, 1988--
01002C1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other19$0$0Jul 18, 1988--
Jul 3, 1985Planned (H) · Complete scope, Safety#17605114$03 viol.

Inspection #17605114

Dates

Opened
Jul 3, 1985
Closing Conference Date
Jul 3, 1985
Closed
Aug 2, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
270 South College Street, Washington, PA 15301
Industry
453998 All Other Miscellaneous Store Retailers (except Tobacco Stores)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other116$0$0Jul 26, 1985--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other116$0$0Aug 8, 1985--
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other116$0$0Jul 26, 1985--
Jan 21, 1982Complaint (B) · Complete scope, Safety#12990321$1502 viol.

Inspection #12990321

Dates

Opened
Jan 21, 1982
Closing Conference Date
Jan 21, 1982
Closed
Mar 3, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
12
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$240
Penalties on Record
$150
Site Address
244 South College Street, Washington, PA 15301
Industry
453998 All Other Miscellaneous Store Retailers (except Tobacco Stores)

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious1-$120$75Mar 2, 1982--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious1-$120$75Mar 2, 1982--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)12 citations · $12,880
1910.1200Hazard Communication6 citations · $0
1910.219Mechanical Power-Transmission Apparatus5 citations · $3,090

Industry comparison

Violations per inspection
This employer4.6
Industry average1.8
Penalties per inspection
This employer$2,906
Industry average$2,526

NAICS 453, 5,558 employers with OSHA inspections. Arithmetic from DOL records.