CLIFCO METAL MANUFACTURING INC
2458 N RULON WHITE BLVD, OGDEN, UT 84404
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Dec 5, 2008#312406515Dec 5, 2008Planned (H) · Complete scope, Safety#312406515$2,5005 viol.5 violations$2,500 in penalties
Inspection #312406515
Dates
- Opened
- Dec 5, 2008
- Closing Conference Date
- Dec 11, 2008
- Closed
- Mar 12, 2009
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 4 serious, 1 repeat
- Initial Penalties
- $12,000
- Penalties on Record
- $2,500
- Site Address
- 2458 N Rulon White Blvd, Ogden, UT 84404
- Industry
- 332322 Sheet Metal Work Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Repeat | 1 | 1 | $6,000 | $1,250 | Dec 30, 2008 | - | - |
| 02001A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 1 | $3,000 | $625 | Feb 15, 2009 | - | - |
| 02001B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 I | Serious | 1 | 1 | $0 | $0 | Feb 15, 2009 | - | - |
| 02002A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $3,000 | $625 | Feb 12, 2009 | - | - |
| 02002B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 1 | $0 | $0 | Dec 30, 2008 | - | - |
Mar 31, 2006#309168060Mar 31, 2006Planned (H) · Complete scope, Safety#309168060$2,46515 viol.15 violations$2,465 in penalties
Inspection #309168060
Dates
- Opened
- Mar 31, 2006
- Closing Conference Date
- Mar 31, 2006
- Closed
- May 21, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 45
Violations and Penalties
- Total Violations
- 15
- Violation Types
- 11 serious, 4 other-than-serious
- Initial Penalties
- $6,163
- Penalties on Record
- $2,465
- Site Address
- 2458 N Rulon White Blvd, Ogden, UT 84404
- Industry
- 332322 Sheet Metal Work Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 15 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L04 III | Serious | 1 | 17 | $700 | $280 | May 31, 2006 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 6 | $1,488 | $595 | Mar 31, 2006 | - | - |
| 01003A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | 3 | $1,225 | $490 | May 19, 2006 | - | - |
| 01003B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 1 | $0 | $0 | May 19, 2006 | - | - |
| 01004A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B01 | Serious | 5 | 36 | $2,500 | $1,000 | May 19, 2006 | - | - |
| 01004B | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Serious | 3 | 24 | $0 | $0 | May 19, 2006 | - | - |
| 01004C | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 VC3 | Serious | 1 | 3 | $0 | $0 | May 19, 2006 | - | - |
| 01004D | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 2 | 24 | $0 | $0 | May 19, 2006 | - | - |
| 01004E | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 C02 | Serious | 1 | 8 | $0 | $0 | May 5, 2006 | - | - |
| 01004F | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 II | Serious | 3 | 35 | $0 | $0 | May 19, 2006 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Oct 25, 1999#301163622Oct 25, 1999Planned (H) · Complete scope, Health#301163622$06 viol.6 violations$0 in penalties
Inspection #301163622
Dates
- Opened
- Oct 25, 1999
- Closing Conference Date
- Oct 25, 1999
- Closed
- Dec 5, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 2458 N Rulon White Blvd, Ogden, UT 84404
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Other | 1 | 1 | $0 | $0 | Nov 29, 1999 | - | - |
| 01002 | 1910.36 Design and Construction Requirements for Exit Routes OSHA citation code: 19100036 B04 | Other | 1 | 1 | $0 | $0 | Nov 29, 1999 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Other | 2 | 3 | $0 | $0 | Nov 29, 1999 | - | - |
| 01004 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B04 | Other | 1 | 1 | $0 | $0 | Nov 29, 1999 | - | - |
| 01005 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Other | 3 | 3 | $0 | $0 | Nov 29, 1999 | - | - |
| 01006 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Other | 1 | 1 | $0 | $0 | Nov 29, 1999 | - | - |
Oct 5, 1993#124619339Oct 5, 1993Planned (H) · Complete scope, Health#124619339$1,3503 viol.3 violations$1,350 in penalties
Inspection #124619339
Dates
- Opened
- Oct 5, 1993
- Closing Conference Date
- Oct 5, 1993
- Closed
- Dec 20, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 33
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 2 serious, 1 other-than-serious
- Initial Penalties
- $1,350
- Penalties on Record
- $1,350
- Site Address
- 2458 N Rulon White Blvd, Ogden, UT 84404
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 | Serious | 1 | 1 | $1,350 | $1,350 | Nov 27, 1993 | - | - |
| 01001B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Serious | 1 | 1 | $0 | $0 | Dec 8, 1993 | - | - |
| 02001 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 P01 | Other | 1 | 1 | $0 | $0 | Dec 3, 1993 | - | - |
Oct 28, 1986#102094000Oct 28, 1986Planned (H) · Complete scope, Safety#102094000$04 viol.4 violations$0 in penalties
Inspection #102094000
Dates
- Opened
- Oct 28, 1986
- Closing Conference Date
- Oct 28, 1986
- Closed
- Jan 7, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 14
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 2458 N Rulon White Blvd, Ogden, UT 84404
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | GEN01781601 | Other | 3 | 4 | $0 | $0 | Nov 20, 1986 | - | - |
| 01002 | GEN01820101 | Other | 1 | 4 | $0 | $0 | Nov 20, 1986 | - | - |
| 01003 | GEN03040102 | Other | 1 | 4 | $0 | $0 | Nov 20, 1986 | - | - |
| 01004 | GEN03050202 | Other | 1 | 4 | $0 | $0 | Nov 20, 1986 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1986 to 2008. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Industry comparison
BLS 2024 survey: sheet metal work manufacturing reported 3.3 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.4%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source