G T FABRICATION INC
100 BENEDICT STREET, PITTSTON, PA 18640 · NAICS 332312 Fabricated Structural Metal Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 24, 2008#310232954Apr 24, 2008Planned (H) · Partial scope, Safety#310232954$2,88716 viol.16 violations$2,887 in penalties
Inspection #310232954
Dates
- Opened
- Apr 24, 2008
- Closing Conference Date
- May 21, 2008
- Closed
- Jul 11, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
Violations and Penalties
- Total Violations
- 16
- Violation Types
- 16 serious
- Initial Penalties
- $4,125
- Penalties on Record
- $2,887
- Site Address
- 100 Benedict Street, Pittston, PA 18640
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (12 of 16 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 5 | $525 | $367 | Jun 25, 2008 | - | - |
| 01002A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B06 I | Serious | 1 | 1 | $525 | $367 | Jun 25, 2008 | - | - |
| 01002B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Serious | 1 | 1 | $0 | $0 | Jun 25, 2008 | - | - |
| 01002C | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 F02 | Serious | 1 | 1 | $0 | $0 | Jun 25, 2008 | - | - |
| 01003A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Serious | 1 | 3 | $300 | $210 | Jun 25, 2008 | - | - |
| 01003B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 I | Serious | 1 | 3 | $0 | $0 | Jun 25, 2008 | - | - |
| 01004A | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 3 | $525 | $367 | Jun 25, 2008 | - | - |
| 01004B | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D02 | Serious | 1 | 3 | $0 | $0 | Jun 25, 2008 | - | - |
| 01005 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 B02 III | Serious | 1 | 6 | $525 | $367 | Jun 25, 2008 | - | - |
| 01006 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 3 | $300 | $210 | Jun 25, 2008 | - | - |
| 01007A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B07 I | Serious | 3 | 2 | $525 | $367 | Jun 25, 2008 | - | - |
| 01007B | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F02 | Serious | 2 | 2 | $0 | $0 | Jun 25, 2008 | - | - |
Showing the 12 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 25, 1998#301039293Mar 25, 1998Planned (H) · Partial scope, Safety#301039293$2,3756 viol.6 violations$2,375 in penalties
Inspection #301039293
Dates
- Opened
- Mar 25, 1998
- Closing Conference Date
- Mar 31, 1998
- Closed
- Apr 27, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 22
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 serious
- Initial Penalties
- $2,375
- Penalties on Record
- $2,375
- Site Address
- 100 Benedict Street, Pittston, PA 18640
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B06 II | Serious | 3 | 4 | $625 | $625 | Apr 9, 1998 | - | - |
| 01002 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B08 III | Serious | 1 | 4 | $625 | $625 | Apr 24, 1998 | - | - |
| 01003 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 D06 I | Serious | 1 | 4 | $375 | $375 | Apr 24, 1998 | - | - |
| 01004A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Serious | 1 | 4 | $375 | $375 | Apr 24, 1998 | - | - |
| 01004B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 II | Serious | 1 | 4 | $0 | $0 | Apr 24, 1998 | - | - |
| 01005 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 F02 | Serious | 1 | 4 | $375 | $375 | Apr 24, 1998 | - | - |
Feb 14, 1995#17616590Feb 14, 1995Follow-Up (F) · Partial scope, Safety#17616590$5255 viol.5 violations$525 in penalties
Inspection #17616590
Dates
- Opened
- Feb 14, 1995
- Closing Conference Date
- Feb 14, 1995
- Closed
- May 11, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 8
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 2 serious, 3 other-than-serious
- Initial Penalties
- $525
- Penalties on Record
- $525
- Site Address
- 100 Benedict Street, Pittston, PA 18640
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C01 | Serious | 4 | 2 | $300 | $300 | Apr 11, 1995 | - | - |
| 01002 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 2 | $225 | $225 | Apr 11, 1995 | - | - |
| 02001 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 | Other | 1 | 2 | $0 | $0 | Apr 11, 1995 | - | - |
| 02002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 | Other | 1 | 2 | $0 | $0 | Apr 11, 1995 | - | - |
| 02003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 C | Other | 1 | 2 | $0 | $0 | Apr 11, 1995 | - | - |
Jun 20, 1994#17624594Jun 20, 1994Complaint (B) · Partial scope, Safety#17624594$1,6009 viol.9 violations$1,600 in penalties
Inspection #17624594
Dates
- Opened
- Jun 20, 1994
- Closing Conference Date
- Jun 20, 1994
- Closed
- Mar 17, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 5
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 6 serious, 3 other-than-serious
- Initial Penalties
- $2,400
- Penalties on Record
- $1,600
- Site Address
- 100 Benedict Street, Pittston, PA 18640
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (9 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C01 | Serious | 4 | 4 | $600 | $400 | Sep 1, 1994 | - | - |
| 01001B | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 4 | 4 | $0 | $0 | Aug 1, 1994 | - | - |
| 01002A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C03 IE | Serious | 1 | 4 | $600 | $400 | Aug 10, 1994 | - | - |
| 01002B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Serious | 1 | 4 | $0 | $0 | Aug 1, 1994 | - | - |
| 01003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 4 | 4 | $600 | $400 | Jul 6, 1994 | - | - |
| 01004 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 4 | $600 | $400 | Sep 1, 1994 | - | - |
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 4 | $0 | $0 | Sep 1, 1994 | - | - |
| 02002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 4 | $0 | $0 | Jul 6, 1994 | - | - |
| 02003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Other | 4 | 4 | $0 | $0 | Jul 6, 1994 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 1994 to 2008. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Fabricated Metal Product Manufacturing, 47,284 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: fabricated structural metal manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source