PEACE FROGS, INC.
$2,253
penalties
29
viol.
4
insp.

PEACE FROGS, INC.

7546 JOHN CLAYTON MEMORIAL HIGHWAY, GLOUCESTER, VA 23061NAICS 323113 Commercial Screen Printing

Inspections
4
Aug 2006 to Aug 2011 · 2 safety, 2 health
Violations
29
across 4 inspections
Penalties on record
$2,253
latest amounts in DOL records
By classification
Serious 17Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 4, 2011Referral (C) · Complete scope, Health#315872408$6623 viol.

Inspection #315872408

Dates

Opened
Aug 4, 2011
Closing Conference Date
Aug 4, 2011
Closed
Nov 15, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$945
Penalties on Record
$662
Site Address
7546 John Clayton Memorial Hwy, Gloucester, VA 23061
Industry
323113 Commercial Screen Printing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 C
Serious11$315$221Oct 15, 2011--
010021910.1052
Methylene Chloride
OSHA citation code: 19101052 D01 I
Serious11$315$221Nov 30, 2011--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious11$315$220Oct 30, 2011--
Aug 4, 2011Complaint (B) · Partial scope, Safety#315872234$7363 viol.

Inspection #315872234

Dates

Opened
Aug 4, 2011
Closing Conference Date
Sep 14, 2011
Closed
Oct 31, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,050
Penalties on Record
$736
Site Address
7546 John Clayton Highway, Gloucester, VA 23061
Industry
323113 Commercial Screen Printing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Serious11$315$221Oct 1, 2011--
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Serious22$315$221Oct 3, 2011--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious22$420$294Oct 3, 2011--
Sep 14, 2006Referral (C) · Partial scope, Health#310485149$05 viol.

Inspection #310485149

Dates

Opened
Sep 14, 2006
Closing Conference Date
Sep 14, 2006
Closed
Dec 4, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
7546 John Clayton Memorial Highway, Gloucester, VA 23061
Industry
323113 Commercial Screen Printing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other16$0$0Oct 30, 2006--
010021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F04
Other16$0$0Oct 30, 2006--
010031910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other16$0$0Oct 30, 2006--
010041910.134
Respiratory Protection
OSHA citation code: 19100134 C02 II
Other16$0$0Nov 26, 2006--
010051910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 I
Other15$0$0Nov 26, 2006--
Aug 9, 2006Complaint (B) · Partial scope, Safety#310356639$85518 viol.

Inspection #310356639

Dates

Opened
Aug 9, 2006
Closing Conference Date
Sep 5, 2006
Closed
Nov 14, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20
Related Activity
1 complaint

Violations and Penalties

Total Violations
18
Violation Types
11 serious, 7 other-than-serious
Initial Penalties
$1,500
Penalties on Record
$855
Site Address
7546 John Clayton Memorial Highway, Gloucester, VA 23061
Industry
323113 Commercial Screen Printing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 A03
Serious55$450$225Sep 25, 2006--
01001B1910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B03
Serious55$0$0Sep 26, 2006--
01001C1910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B06
Serious2020$0$0Sep 25, 2006--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious44$1,050$270Sep 26, 2006--
01004C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIID
Serious310$0$0Sep 26, 2006--
01005A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious55$0$360Sep 29, 2006--
01005B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Serious320$0$0Sep 26, 2006--
01005C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIIA
Serious310$0$0Sep 26, 2006--
01005D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIIB
Serious11$0$0Sep 26, 2006--
01005E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIID
Serious310$0$0Sep 26, 2006--
01005F1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 II
Serious11$0$0Sep 26, 2006--
020011904.33
Retention and updating
OSHA citation code: 19040033 A
Other2020$0$0Oct 24, 2006--

Showing the 12 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment6 citations · $294
1910.1200Hazard Communication4 citations · $220
1910.303Electrical - General Requirements3 citations · $581

Industry comparison

Violations per inspection
This employer7.3
Industry average2.9
Penalties per inspection
This employer$563
Industry average$1,570

Printing and Related Support Activities, 9,063 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: commercial screen printing reported 1.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in GLOUCESTER, VA

All employers in GLOUCESTER →