Skip to content
SafetyRecord logoSafetyRecord

Inspection #310470034

Closed

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a accident inspection of RPI COATING, INC. at Cabin Creek Hydro Generation Station, Georgetown, CO 80444 on Oct 2, 2007. The inspection scope was partial. The case was closed on Jan 11, 2016.

OSHA documented 46 violations (28 serious, 2 other-than-serious) with total penalties on record of $100,000. 1 incident investigation summary is associated with this inspection. This inspection is linked to 1 referral, 1 accident report in OSHA records.

OSHA collected 13 air monitoring samples covering 7 substances during this inspection, including 2-Butanone, Benzene, Carbon Monoxide (by COHb), Naphtha (Coal Tar), Particulates not otherwise regulated (Total Dust), and 2 more.

Inspection Details
Inspection Number
310470034
Type
Accident (A)
Scope
Partial
Opened
Oct 2, 2007
Closed
Jan 11, 2016
Contested
Apr 14, 2008
Final Order
Jan 20, 2012
Total Violations
46
Penalties on Record
$100,000
Initial Penalties
$845,100
Related Activity
1 referral, 1 accident
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Establishment
Address
Cabin Creek Hydro Generation Station, Georgetown, CO 80444
Industry
237310 Highway, Street, and Bridge Construction
Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection appears immediately below.

FatalityOct 2, 2007

Five employees asphyxiated by vapors from chemical fire

Injury: AsphyxiaBody part: Body System

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed Jan 11, 2016.

Citations on Record
46

28 serious, 2 other-than-serious.

Initial Penalties
$845,100

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$100,000

Latest published amounts after changes in the enforcement process.

Citation contest activity appears on Apr 14, 2008. Final orders are recorded through Jan 20, 2012. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.
Chemical Exposure Sampling7 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone10ppm
Benzene10ppm
Carbon Monoxide (by COHb)5869.5 - 1513.3ppm
Gravimetric DeterminationQC10.2199mg/m³
Naphtha (Coal Tar)10mg/m³
Particulates not otherwise regulated (Total Dust)10.2199mg/m³
Phenol10mg/m³
Sample WeightQC10.088mg
Toluene10ppm

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value.

CitationStandardTypeInitialCurrentAbatement
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious$1,800$1,000Dec 19, 2011
010021910.23
Ladders
OSHA citation code: 19100023 D01
Serious$1,800$1,000Dec 19, 2011
010031910.106
Flammable Liquids
OSHA citation code: 19100106 D06 IV
Serious$1,800$1,000Dec 19, 2011
01004A1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 II
Serious$4,500$1,000Dec 19, 2011
01004B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 III
Serious$0$0Dec 19, 2011
010051910.106
Flammable Liquids
OSHA citation code: 19100106 E05 I
Serious$2,250$1,000Dec 19, 2011
010061910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious$2,250$1,000Dec 19, 2011
010071910.134
Respiratory Protection
OSHA citation code: 19100134 D01 I
Serious$4,500$1,000Dec 19, 2011
010081910.134
Respiratory Protection
OSHA citation code: 19100134 E06 II
Serious$4,500$1,000Dec 19, 2012
010091910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious$1,800$1,000Dec 19, 2011
010101910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious$4,500$1,000Dec 19, 2011
01011A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 F07
Serious$4,500$1,000Dec 19, 2011
01011B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 F13
Serious$0$0Dec 19, 2011
010121910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 II
Serious$1,800$1,000Dec 19, 2011
010131910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious$2,250$1,000Dec 19, 2011
010141910.303
Electrical - General Requirements
OSHA citation code: 19100303 B08 I
Serious$1,800$1,000Dec 19, 2011
010151910.303
Electrical - General Requirements
OSHA citation code: 19100303 F02
Serious$1,800$1,000Dec 19, 2011
010161910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious$2,250$1,000Dec 19, 2011
010171910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F01 I
Serious$4,500$1,000Dec 19, 2011
010181910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 G05
Serious$1,800$1,000Dec 19, 2011
010191910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 X
Serious$1,800$1,000Dec 19, 2011
010201910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 XI
Serious$2,250$1,000Dec 19, 2011
010211910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 I
Serious$1,800$1,000Dec 19, 2011
010221910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious$2,250$1,000Dec 19, 2011
010231910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J04 V
Serious$1,800$1,000Dec 19, 2011
010241910.307
Electrical - Hazardous (Classified) Locations
OSHA citation code: 19100307 C
Serious$1,800$1,000Dec 19, 2011
01025A1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Serious$4,500$1,000Dec 19, 2011
01025B1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious$0$0Dec 19, 2011
02001A1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVA
Other$63,000$5,770Dec 19, 2011
02001B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVD
Other$0$0Dec 19, 2011
020021910.106
Flammable Liquids
OSHA citation code: 19100106 E05 I
Other$63,000$5,770Dec 19, 2011
020031910.106
Flammable Liquids
OSHA citation code: 19100106 E07 IA
Other$63,000$5,770Dec 19, 2011
020041910.106
Flammable Liquids
OSHA citation code: 19100106 E07 IA
Other$63,000$5,770Dec 19, 2011
020051910.106
Flammable Liquids
OSHA citation code: 19100106 E07 IA
Other$63,000$5,770Dec 19, 2011
020061910.134
Respiratory Protection
OSHA citation code: 19100134 I07
Other$36,000$5,760Dec 19, 2011
02007A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C09 II
Other$49,500$5,770Dec 19, 2011
02007B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D11
Other$0$0Dec 19, 2011
020081910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D04 II
Other$63,000$5,770Dec 19, 2011
020091910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D05 I
Other$63,000$5,770Dec 19, 2011
020101910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D13
Other$63,000$5,770Dec 19, 2011
02011A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 K01 I
Other$63,000$5,770Dec 19, 2011
02011B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 K01 II
Other$0$0Dec 19, 2011
020121910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 G05
Other$63,000$5,770Dec 19, 2011
020131910.1200
Hazard Communication
OSHA citation code: 19101200 H03 III
Other$63,000$5,770Dec 19, 2011
030011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 G04
Other$0$0Dec 19, 2011
030021910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other$0$0Dec 19, 2011

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.