Inspection #311685630
ClosedThis page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
The Occupational Safety and Health Administration (OSHA) conducted a referral inspection of WILSON WORKS, INC at 202 Distributor Drive, Morgantown, WV 26501 on Feb 23, 2009. The inspection scope was complete. The case was closed on Nov 13, 2012.
OSHA documented 12 violations (10 serious, 2 other-than-serious) with total penalties on record of $5,300. This inspection is linked to 1 referral in OSHA records.
OSHA collected 66 air monitoring samples covering 16 substances during this inspection, including 2-Butanone, Antimony and Compounds (as Sb), Beryllium and Beryllium Compounds (as Be), Cadmium, Chromic Acid and Chromates (as CrO3), and 11 more.
This employer has 2 other OSHA inspections on record at this establishment.
- Inspection Number
- 311685630
- Type
- Referral (C)
- Scope
- Complete
- Opened
- Feb 23, 2009
- Closed
- Nov 13, 2012
- Total Violations
- 12
- Penalties on Record
- $5,300
- Initial Penalties
- $7,500
- Related Activity
- 1 referral
- Address
- 202 Distributor Drive, Morgantown, WV 26501
- Industry
- 332710 Machine Shops
| Inspection | Type | Violations | Penalties |
|---|---|---|---|
| #348433939 | Planned (H) | 2 violations | $6,620 |
| #311679914 | Planned (H) | 19 violations | $11,735 |
Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.
Inspection closed Nov 13, 2012.
10 serious, 2 other-than-serious.
Citation amounts as first recorded in OSHA's penalty fields.
Latest published amounts after changes in the enforcement process.
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| 2-Butanone | 2 | 4.803553 - 301.529775 | ppm |
| Antimony and Compounds (as Sb) | 4 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 4 | 0 | mg/m³ |
| Cadmium | 4 | 0 | mg/m³ |
| Chromic Acid and Chromates (as CrO3) | 6 | 0 - 0.001006 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 4 | 0 | mg/m³ |
| Chromium (VI) - TWA | 6 | 0 - 0.000523 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 4 | 0 | mg/m³ |
| Copper Fume (as Cu) | 4 | 0.0079135 - 0.0506258 | mg/m³ |
| Iron Oxide Fume | 4 | 0.8727965 - 6.878603 | mg/m³ |
| Lead, Inorganic (as Pb) | 4 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 4 | 0.0544397 - 0.532517 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 4 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 4 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 4 | 0 | mg/m³ |
| Zinc Oxide Fume | 4 | 0 - 0.0894727 | mg/m³ |
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value.
| Citation | Standard | Type | Initial | Current | Abatement |
|---|---|---|---|---|---|
| 01001A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Serious | $2,500 | $2,000 | May 29, 2009 |
| 01001B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 D01 | Serious | $0 | $0 | May 14, 2009 |
| 01001C | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G01 | Serious | $0 | $0 | May 14, 2009 |
| 01001D | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 K01 | Serious | $0 | $0 | May 14, 2009 |
| 01001E | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 L01 | Serious | $0 | $0 | May 8, 2009 |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B01 | Serious | $2,500 | $1,300 | May 12, 2009 |
| 01002B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Serious | $0 | $0 | May 12, 2009 |
| 01002C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 E02 | Serious | $0 | $0 | May 8, 2009 |
| 01004A | 1910.134 Respiratory Protection OSHA citation code: 19100134 I05 IV | Serious | $2,500 | $2,000 | May 8, 2009 |
| 01004B | 1910.134 Respiratory Protection OSHA citation code: 19100134 I07 | Serious | $0 | $0 | May 8, 2009 |
| 02001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 IA | Other | $0 | $0 | May 8, 2009 |
| 02002 | 1910.1026 Chromium (VI) OSHA citation code: 19101026 D01 | Other | $0 | $0 | May 8, 2009 |
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
Data Source and Methodology
Data synced dailyData on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.