THE COLONIAL/HAN-DEE SPRING COMPANY, LLC
95 VALLEY STREET, BRISTOL, CT 06010 · NAICS 332116
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 25, 2010#311796874Jan 25, 2010Programmed Related (I) · Partial scope, Health#311796874$01 viol.1 violation$0 in penalties
Inspection #311796874
Dates
- Opened
- Jan 25, 2010
- Closing Conference Date
- Feb 22, 2010
- Closed
- Apr 16, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 25
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 95 Valley Street, Bristol, CT 06010
- Industry
- 332116
Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 1 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 1 | 0 | mg/m³ |
| Cadmium | 1 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 1 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 1 | 0 | mg/m³ |
| Copper Fume (as Cu) | 1 | 0 | mg/m³ |
| Iron Oxide Fume | 1 | 0 | mg/m³ |
| Lead, Inorganic (as Pb) | 1 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 1 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 1 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 1 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 1 | 0 | mg/m³ |
| Zinc Oxide Fume | 1 | 0 | mg/m³ |
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C02 I | Other | 1 | 1 | $0 | $0 | May 10, 2010 | - | - |
Jan 6, 2010#311763023Jan 6, 2010Planned (H) · Complete scope, Safety#311763023$6,00021 viol.21 violations$6,000 in penalties
Inspection #311763023
Dates
- Opened
- Jan 6, 2010
- Closing Conference Date
- Jan 8, 2010
- Closed
- Nov 1, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 21
- Violation Types
- 17 serious, 4 other-than-serious
- Initial Penalties
- $12,000
- Penalties on Record
- $6,000
- Site Address
- 95 Valley Street, Bristol, CT 06010
- Industry
- 332116
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (21 of 21 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 4 | $750 | $375 | May 18, 2010 | - | - |
| 01002A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | 3 | $600 | $300 | May 18, 2010 | - | - |
| 01002B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B05 | Serious | 1 | 3 | $0 | $0 | May 18, 2010 | - | - |
| 01003 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 D09 III | Serious | 1 | 2 | $450 | $225 | May 18, 2010 | - | - |
| 01004 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 II | Serious | 2 | 4 | $750 | $375 | May 18, 2010 | - | - |
| 01005 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B01 | Serious | 1 | 4 | $600 | $300 | May 18, 2010 | - | - |
| 01006 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 2 | $600 | $300 | May 18, 2010 | - | - |
| 01007 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Serious | 4 | 5 | $450 | $225 | May 18, 2010 | - | - |
| 01008 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 | Serious | 1 | 2 | $450 | $225 | May 18, 2010 | - | - |
| 01009 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 G06 VI | Serious | 1 | 6 | $750 | $375 | May 18, 2010 | - | - |
| 01010 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 II | Serious | 2 | 6 | $600 | $300 | May 18, 2010 | - | - |
| 01011 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 F01 | Serious | 1 | 2 | $450 | $225 | May 18, 2010 | - | - |
| 01012 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 IV | Serious | 8 | 10 | $600 | $300 | May 18, 2010 | - | - |
| 01013 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 3 | 6 | $450 | $225 | May 18, 2010 | - | - |
| 01014 | 1910.332 Electrical Safety-Related Work Practices - Training OSHA citation code: 19100332 B01 | Serious | 1 | 1 | $1,500 | $750 | Jun 18, 2010 | - | - |
| 01015 | 1910.333 Electrical - Selection and Use of Work Practices OSHA citation code: 19100333 A | Serious | 1 | 1 | $1,500 | $750 | Jun 18, 2010 | - | - |
| 01016 | 1910.335 Electrical - Safeguards OSHA citation code: 19100335 A01 I | Serious | 1 | 1 | $1,500 | $750 | May 18, 2010 | - | - |
| 02001 | 1910.24 Step Bolts and Manhole Steps OSHA citation code: 19100024 H | Other | 1 | 4 | $0 | $0 | May 18, 2010 | - | - |
| 02002 | 1910.36 Design and Construction Requirements for Exit Routes OSHA citation code: 19100036 D01 | Other | 1 | 5 | $0 | $0 | Apr 6, 2010 | - | - |
| 02003 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Other | 1 | 2 | $0 | $0 | May 18, 2010 | - | - |
| 02004 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F02 | Other | 4 | 2 | $0 | $0 | May 18, 2010 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 2010 to 2010. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Industry comparison
Fabricated Metal Product Manufacturing, 47,300 employers with OSHA inspections. Arithmetic from DOL records.