Skip to content
SafetyRecord logoSafetyRecord

Inspection #312581580

Closed

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a referral inspection of CUSTOM-PAK, INC. at 9060 Crisfield Highway, Westover, MD 21871 on Sep 18, 2008. The inspection scope was complete. The case was closed on Jan 7, 2009.

OSHA documented 49 violations (35 serious, 14 other-than-serious) with total penalties on record of $25,000. This inspection is linked to 1 referral in OSHA records.

This employer has 3 other OSHA inspections on record at this establishment.

Inspection Details

Inspection Number
312581580
Type
Referral (C)
Scope
Complete
Opened
Sep 18, 2008
Closed
Jan 7, 2009
Total Violations
49
Penalties on Record
$25,000
Initial Penalties
$79,099
Related Activity
1 referral
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Establishment

Address
9060 Crisfield Highway, Westover, MD 21871
Industry
425120 Wholesale Trade Agents and Brokers

Other Inspections of This Employer3 on record

Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed Jan 7, 2009.

Citations on Record
49

35 serious, 14 other-than-serious.

Initial Penalties
$79,099

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$25,000

Latest published amounts after changes in the enforcement process.

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

CitationStandardTypeInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B01
Serious$3,000$1,315Nov 20, 2008--
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Serious$3,000$1,324Nov 20, 2008--
01003A1910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 B06 II
Serious$3,000$1,334Nov 20, 2008--
01003B1910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 B14 VI
Serious$0$0Nov 20, 2008--
010041910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 D10
Serious$3,000$1,284Sep 19, 2008--
010051910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F01
Serious$2,625$1,094Dec 31, 2008--
01006A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious$2,625$1,084Dec 31, 2008--
01006B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Serious$0$0Dec 31, 2008--
01006C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious$0$0Dec 31, 2008--
01006D1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 F02 I
Serious$0$0Dec 31, 2008--
010071910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious$2,625$964Nov 20, 2008--
01008A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A04
Serious$2,250$974Nov 20, 2008--
01008B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A05
Serious$0$0Nov 20, 2008--
010101910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious$2,625$1,174Nov 20, 2008--
010111910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Serious$2,625$1,154Nov 12, 2008--
010121910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious$1,875$960Nov 20, 2008--
010131910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious$750$285Nov 20, 2008--
010141910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious$1,875$720Nov 20, 2008--
010151910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious$2,625$503Nov 20, 2008--
010161910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 II
Serious$2,625$505Nov 20, 2008--
01017A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious$2,625$575Nov 20, 2008--
01017B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious$0$0Nov 20, 2008--
010181910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious$2,625$510Nov 20, 2008--
010191910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious$2,625$515Nov 20, 2008--
010201910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious$2,625$520Nov 20, 2008--
010211910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 I
Serious$2,250$525Nov 20, 2008--
010221910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious$3,000$950Nov 20, 2008--
010231910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious$1,312$290Nov 17, 2008--
010241910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious$3,000$705Nov 20, 2008--
010251910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 E02
Serious$3,000$580Nov 20, 2008--
01026A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 IV
Serious$3,000$1,090Nov 20, 2008--
01026B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 VII
Serious$0$0Nov 20, 2008--
01027A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious$3,000$1,271Nov 20, 2008--
01027B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious$0$0Nov 20, 2008--
01027C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious$0$0Dec 31, 2008--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other$1,500$450Nov 20, 2008--
020021910.23
Ladders
OSHA citation code: 19100023 C01
Other$1,500$425Nov 20, 2008--
020031910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Other$1,500$700Nov 20, 2008--
020041910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other$750$450Nov 20, 2008--
02005A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other$1,125$250Dec 31, 2008--
02005B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 II
Other$0$0Dec 31, 2008--
020061910.176
Handling Materials - General
OSHA citation code: 19100176 E
Other$750$80Nov 20, 2008--
020071910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other$750$40Nov 20, 2008--
020081910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Other$1,500$75Nov 20, 2008--
020091910.303
Electrical - General Requirements
OSHA citation code: 19100303 F02
Other$1,125$160Nov 20, 2008--
020101910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Other$562$45Nov 17, 2008--
020111910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IV
Other$1,500$70Nov 20, 2008--
02012A50405
OSHA citation code: 50405 B01
Other$350$50Nov 20, 2008--
02012B50406
OSHA citation code: 50406 A01
Other$0$0Dec 9, 2008--

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.