Skip to content
SafetyRecord logoSafetyRecord
KEIR MANUFACTURING, INC.
$1,450
penalties
33
viol.
6
insp.

KEIR MANUFACTURING, INC.

430 RAILROAD AVENUE, BREVARD, NC 28712

Inspections
6
Apr 1990 to Nov 2008 · 5 safety, 1 health
Violations
33
across 6 inspections
Penalties on record
$1,450
latest amounts in DOL records
By classification
Serious 16Willful 0Repeat 0Other 17

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 17, 2008Planned (H) · Complete scope, Safety#312721335$50013 viol.

Inspection #312721335

Dates

Opened
Nov 17, 2008
Closing Conference Date
Nov 17, 2008
Closed
Jan 13, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
13
Violation Types
8 serious, 5 other-than-serious
Initial Penalties
$500
Penalties on Record
$500
Site Address
133 Mclean Road, Brevard, NC 28712
Industry
333292

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A9501.2901Serious11$100$100Jan 8, 2009--
01001B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04 III
Serious13$0$0Jan 8, 2009--
01001C1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Serious14$0$0Jan 8, 2009--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious36$100$100Jan 8, 2009--
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious26$100$100Jan 8, 2009--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 G05
Serious26$100$100Dec 2, 2008--
01005A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious13$100$100Dec 2, 2008--
01005B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious13$0$0Dec 2, 2008--

Showing the 8 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 22, 2003Planned (H) · Complete scope, Safety#306846882$40010 viol.

Inspection #306846882

Dates

Opened
Jul 22, 2003
Closing Conference Date
Jul 22, 2003
Closed
Aug 12, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
10
Violation Types
4 serious, 6 other-than-serious
Initial Penalties
$400
Penalties on Record
$400
Site Address
430 Railroad Avenue, Brevard, NC 28712
Industry
333999 All Other Miscellaneous General Purpose Machinery Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$100$100Aug 8, 2003--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$100$100Aug 8, 2003--
010031910.263
Bakery Equipment
OSHA citation code: 19100263 E01 VIII
Serious21$100$100Sep 15, 2003--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$100$100Aug 8, 2003--
020011910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Other116$0$0Sep 15, 2003--
020021910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other11$0$0Aug 8, 2003--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other11$0$0Aug 8, 2003--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other11$0$0Aug 8, 2003--

Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 27, 1996Planned (H) · Complete scope, Safety#125229526$1004 viol.

Inspection #125229526

Dates

Opened
Mar 27, 1996
Closing Conference Date
Mar 27, 1996
Closed
Jun 3, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$100
Penalties on Record
$100
Site Address
430 Railroad Avenue, Brevard, NC 28712
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A04
Serious11$100$100May 31, 1996--
020011910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 B
Other11$0$0May 31, 1996--
020021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other11$0$0Apr 29, 1996--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other11$0$0Apr 29, 1996--
Aug 23, 1990Follow-Up (F) · Partial scope, Safety#18544783$00 viol.

Inspection #18544783

Dates

Opened
Aug 23, 1990
Closing Conference Date
Aug 23, 1990
Closed
Aug 23, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
430 Railroad Avenue, Brevard, NC 28712
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 10, 1990Complaint (B) · Partial scope, Health#18493999$00 viol.

Inspection #18493999

Dates

Opened
Jul 10, 1990
Closing Conference Date
Jul 10, 1990
Closed
Nov 29, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
430 Railroad Avenue, Brevard, NC 28712
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Apr 11, 1990Complaint (B) · Partial scope, Safety#3035623$4506 viol.

Inspection #3035623

Dates

Opened
Apr 11, 1990
Closing Conference Date
Apr 11, 1990
Closed
May 29, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
3 serious, 3 other-than-serious
Initial Penalties
$450
Penalties on Record
$450
Site Address
430 Railroad Avenue, Brevard, NC 28712
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious15$120$120May 14, 1990--
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious13$180$180Jun 9, 1990--
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious15$150$150May 14, 1990--
020017B0302
OSHA citation code: 7B0302 A
Other113$0$0May 14, 1990--
020021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other15$0$0May 14, 1990--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other113$0$0May 14, 1990--
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment7 citations · $100
1910.303Electrical - General Requirements5 citations · $330
1910.212General Requirements for All Machines (Machine Guarding)4 citations · $300

Other inspected employers in BREVARD, NC