Skip to content
SafetyRecord logoSafetyRecord
TRACHTE SOUTHEAST, LLC
$50,453
penalties
33
viol.
3
insp.

TRACHTE SOUTHEAST, LLC

1249 CLARY CONNECTOR, EASTANOLLEE, GA 30577NAICS 332312 Fabricated Structural Metal Manufacturing

Inspections
3
Oct 2010 to Dec 2019 · 1 safety, 2 health
Violations
33
across 3 inspections
Penalties on record
$50,453
latest amounts in DOL records
By classification
Serious 29Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 3, 2019Planned (H) · Complete scope, Health#344485479$9,3686 viol.

Inspection #344485479

Dates

Opened
Dec 3, 2019
Closing Conference Date
Dec 5, 2019
Final Order
Jan 7, 2020
Closed
Jan 17, 2020

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
48

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$15,614
Penalties on Record
$9,368
Site Address
1249 Clary Connector, Eastanollee, GA 30577
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious12$3,587$2,152-Jan 7, 2020
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious11$4,220$2,532Jan 13, 2020-Jan 7, 2020
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 II
Serious11$0$0-Jan 7, 2020
01002C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious11$0$0Jan 13, 2020-Jan 7, 2020
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04 III
Serious12$4,220$2,532-Jan 7, 2020
010041910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J02 III
Serious14$3,587$2,152-Jan 7, 2020
Oct 20, 2010Referral (C) · Complete scope, Health#314205667$22,77017 viol.

Inspection #314205667

Dates

Opened
Oct 20, 2010
Closing Conference Date
Nov 18, 2010
Closed
Apr 25, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22
Related Activity
1 referral

Violations and Penalties

Total Violations
17
Violation Types
16 serious, 1 other-than-serious
Initial Penalties
$45,540
Penalties on Record
$22,770
Site Address
1249 Clary Connector, Eastanollee, GA 30577
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling18 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Acetone20.580236 - 0.626167ppm
Antimony and Compounds (as Sb)50mg/m³
Beryllium and Beryllium Compounds (as Be)50mg/m³
Cadmium50mg/m³
Chromium, Metal and Insoluble Salts50mg/m³
Cobalt, Metal, Dust and Fume (as Co)50mg/m³
Copper Fume (as Cu)50 - 0.0286458mg/m³
Gravimetric DeterminationQC11.5885mg/m³
Iron Oxide Fume50 - 2.7536891mg/m³
Lead, Inorganic (as Pb)50mg/m³
Manganese Fume (as Mn)50 - 0.3010417mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)50mg/m³
n-Butyl Acetate30 - 4.080056ppm
Nickel, Metal and Insoluble compounds (as Ni)50mg/m³
Sample WeightQC10.193mg
Silica, Crystalline Quartz (Respirable Fraction)10%
Toluene22.755924 - 3.884695ppm
Vanadium fume (as V2O5)50mg/m³
Xylene20.413661 - 0.792982ppm
Zinc Oxide Fume50mg/m³

Violations

Violation list (16 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious11$3,960$1,980Apr 21, 2011--
010021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious11$3,960$1,980Apr 21, 2011--
010031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious11$3,960$1,980Apr 21, 2011--
010041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B01
Serious13$6,930$3,465Apr 21, 2011--
010051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B10
Serious13$6,930$3,465Apr 21, 2011--
010061910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Serious13$6,930$3,465Apr 21, 2011--
01007A1910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Serious12$2,970$1,485Apr 21, 2011--
01007B1910.134
Respiratory Protection
OSHA citation code: 19100134 D01 I
Serious12$0$0Apr 21, 2011--
01007C1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious22$0$0Apr 21, 2011--
01007D1910.134
Respiratory Protection
OSHA citation code: 19100134 F01
Serious22$0$0Apr 21, 2011--
01007E1910.134
Respiratory Protection
OSHA citation code: 19100134 G01 IA
Serious11$0$0Apr 21, 2011--
01007F1910.134
Respiratory Protection
OSHA citation code: 19100134 H01 I
Serious11$0$0Apr 21, 2011--
01007G1910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious11$0$0Apr 21, 2011--
01007H1910.134
Respiratory Protection
OSHA citation code: 19100134 K03
Serious14$0$0Apr 21, 2011--
010081910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 I
Serious12$3,960$1,980Apr 4, 2011--
010091910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious11$2,970$1,485Apr 4, 2011--

Showing the 16 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 12, 2010Complaint (B) · Complete scope, Safety#314205386$18,31510 viol.

Inspection #314205386

Dates

Opened
Oct 12, 2010
Closing Conference Date
Oct 12, 2010
Closed
Apr 25, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
7 serious, 3 other-than-serious
Initial Penalties
$36,630
Penalties on Record
$18,315
Site Address
1249 Clary Connector, Eastanollee, GA 30577
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 A03
Serious114$2,970$1,485Apr 6, 2011--
010021910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious110$4,950$2,475Apr 6, 2011--
010031910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious11$6,930$3,465Apr 6, 2011--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$6,930$3,465Apr 6, 2011--
010051910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 A
Serious32$3,960$1,980Apr 6, 2011--
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Serious39$3,960$1,980Apr 6, 2011--
010071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious39$6,930$3,465Apr 6, 2011--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other210$0$0Apr 6, 2011--
020021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other13$0$0Apr 6, 2011--
020031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 G05
Other113$0$0Apr 14, 2011--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection9 citations · $3,637
1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $10,395
1910.147Control of Hazardous Energy (Lockout/Tagout)3 citations · $2,532

Chemical exposure sampling

Samples
77
Substances
20
Inspections
1

Industry comparison

Violations per inspection
This employer11.0
Industry average3.3
Penalties per inspection
This employer$16,818
Industry average$2,307

Fabricated Metal Product Manufacturing, 47,300 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in EASTANOLLEE, GA