ROSTAND MANUFACTURING CO
303 W OAK STREET, NORRISTOWN, PA 19401 · NAICS 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 29, 2013#339366916Aug 29, 2013Follow-Up (F) · Partial scope, Health#339366916$00 viol.0 violations$0 in penalties
Inspection #339366916
Dates
- Opened
- Aug 29, 2013
- Closing Conference Date
- Aug 29, 2013
- Closed
- Aug 29, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 303 W Oak Street, Norristown, PA 19401
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Aug 29, 2013#339363368Aug 29, 2013Follow-Up (F) · Partial scope, Safety#339363368$1,6001 viol.1 violation$1,600 in penalties
Inspection #339363368
Dates
- Opened
- Aug 29, 2013
- Closing Conference Date
- Aug 29, 2013
- Final Order
- Dec 5, 2013
- Closed
- Jul 5, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $1,600
- Penalties on Record
- $1,600
- Site Address
- 303 W. Oak Street, Norristown, PA 19401
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 1 | 1 | $1,600 | $1,600 | Oct 8, 2013 | - | Dec 5, 2013 |
Aug 25, 2011#314725904Aug 25, 2011Follow-Up (F) · Partial scope, Safety#314725904$2001 viol.1 violation$200 in penalties
Inspection #314725904
Dates
- Opened
- Aug 25, 2011
- Closing Conference Date
- Sep 7, 2011
- Closed
- Jul 24, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 repeat
- Initial Penalties
- $200
- Penalties on Record
- $200
- Site Address
- 303 W Oak Street, Norristown, PA 19401
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 I | Repeat | 1 | 1 | $200 | $200 | Sep 28, 2011 | - | - |
Aug 25, 2011#314724980Aug 25, 2011Follow-Up (F) · Complete scope, Health#314724980$4,8001 viol.1 violation$4,800 in penalties
Inspection #314724980
Dates
- Opened
- Aug 25, 2011
- Closing Conference Date
- Sep 7, 2011
- Closed
- Jul 14, 2014
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 repeat
- Initial Penalties
- $4,800
- Penalties on Record
- $4,800
- Site Address
- 303 W Oak Street, Norristown, PA 19401
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.126 Additional requirements for special dipping and coating operations OSHA citation code: 19100126 E | Repeat | 1 | 2 | $4,800 | $4,800 | Nov 16, 2011 | - | - |
Jun 23, 2010#312981285Jun 23, 2010Referral (C) · Complete scope, Health#312981285$1,42511 viol.11 violations$1,425 in penalties
Inspection #312981285
Dates
- Opened
- Jun 23, 2010
- Closing Conference Date
- Oct 5, 2010
- Contested
- Nov 11, 2010
- Final Order
- Apr 28, 2011
- Closed
- Jul 19, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 3
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 9 serious, 2 other-than-serious
- Initial Penalties
- $2,850
- Penalties on Record
- $1,425
- Site Address
- 303 W Oak Street, Norristown, PA 19401
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (8 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.124 General Requirements for Dipping and Coating Operations OSHA citation code: 19100124 G02 | Serious | 1 | 1 | $750 | $375 | Nov 5, 2010 | Nov 11, 2010 | Apr 28, 2011 |
| 01002 | 1910.126 Additional requirements for special dipping and coating operations OSHA citation code: 19100126 E | Serious | 1 | 1 | $600 | $300 | Nov 23, 2010 | Nov 11, 2010 | Apr 28, 2011 |
| 01003A | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 1 | $750 | $375 | Nov 16, 2010 | Nov 11, 2010 | Apr 28, 2011 |
| 01003B | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D01 I | Serious | 1 | 1 | $0 | $0 | Nov 16, 2010 | Nov 11, 2010 | Apr 28, 2011 |
| 01003C | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D02 | Serious | 1 | 1 | $0 | $0 | Nov 16, 2010 | Nov 11, 2010 | Apr 28, 2011 |
| 01004A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 1 | $750 | $375 | Nov 16, 2010 | Nov 11, 2010 | Apr 28, 2011 |
| 01004B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Serious | 3 | 1 | $0 | $0 | Nov 23, 2010 | Nov 11, 2010 | Apr 28, 2011 |
| 01004C | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Serious | 4 | 1 | $0 | $0 | Nov 16, 2010 | Nov 11, 2010 | Apr 28, 2011 |
Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jun 23, 2010#312980378Jun 23, 2010Referral (C) · Partial scope, Safety#312980378$2,1756 viol.6 violations$2,175 in penalties
Inspection #312980378
Dates
- Opened
- Jun 23, 2010
- Closing Conference Date
- Jun 23, 2010
- Final Order
- Apr 28, 2011
- Closed
- Apr 16, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 3
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 serious
- Initial Penalties
- $5,400
- Penalties on Record
- $2,175
- Site Address
- 303 W Oak Street, Norristown, PA 19401
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 A04 | Serious | 6 | 3 | $750 | $375 | Nov 9, 2010 | - | Apr 28, 2011 |
| 01002 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Serious | 1 | 3 | $450 | $225 | Oct 7, 2010 | - | Apr 28, 2011 |
| 01003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 1 | 3 | $1,500 | $750 | Nov 9, 2010 | - | Apr 28, 2011 |
| 01006 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 I | Serious | 3 | 3 | $600 | $300 | Nov 9, 2010 | - | Apr 28, 2011 |
| 01007A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 3 | $1,050 | $525 | Nov 9, 2010 | - | Apr 28, 2011 |
| 01007B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 II | Serious | 3 | 3 | $1,050 | $0 | Nov 9, 2010 | - | Apr 28, 2011 |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 2010 to 2013. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Fabricated Metal Product Manufacturing, 47,300 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source