Skip to content
SafetyRecord logoSafetyRecord
ROSTAND MANUFACTURING CO
$10,200
penalties
20
viol.
6
insp.

ROSTAND MANUFACTURING CO

303 W OAK STREET, NORRISTOWN, PA 19401NAICS 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Inspections
6
Jun 2010 to Aug 2013 · 3 safety, 3 health
Violations
20
across 6 inspections
Penalties on record
$10,200
latest amounts in DOL records
By classification
Serious 16Willful 0Repeat 2Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 29, 2013Follow-Up (F) · Partial scope, Health#339366916$00 viol.

Inspection #339366916

Dates

Opened
Aug 29, 2013
Closing Conference Date
Aug 29, 2013
Closed
Aug 29, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
303 W Oak Street, Norristown, PA 19401
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 29, 2013Follow-Up (F) · Partial scope, Safety#339363368$1,6001 viol.

Inspection #339363368

Dates

Opened
Aug 29, 2013
Closing Conference Date
Aug 29, 2013
Final Order
Dec 5, 2013
Closed
Jul 5, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,600
Penalties on Record
$1,600
Site Address
303 W. Oak Street, Norristown, PA 19401
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious11$1,600$1,600Oct 8, 2013-Dec 5, 2013
Aug 25, 2011Follow-Up (F) · Partial scope, Safety#314725904$2001 viol.

Inspection #314725904

Dates

Opened
Aug 25, 2011
Closing Conference Date
Sep 7, 2011
Closed
Jul 24, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$200
Penalties on Record
$200
Site Address
303 W Oak Street, Norristown, PA 19401
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Repeat11$200$200Sep 28, 2011--
Aug 25, 2011Follow-Up (F) · Complete scope, Health#314724980$4,8001 viol.

Inspection #314724980

Dates

Opened
Aug 25, 2011
Closing Conference Date
Sep 7, 2011
Closed
Jul 14, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$4,800
Penalties on Record
$4,800
Site Address
303 W Oak Street, Norristown, PA 19401
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.126
Additional requirements for special dipping and coating operations
OSHA citation code: 19100126 E
Repeat12$4,800$4,800Nov 16, 2011--
Jun 23, 2010Referral (C) · Complete scope, Health#312981285$1,42511 viol.

Inspection #312981285

Dates

Opened
Jun 23, 2010
Closing Conference Date
Oct 5, 2010
Contested
Nov 11, 2010
Final Order
Apr 28, 2011
Closed
Jul 19, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3
Related Activity
1 referral

Violations and Penalties

Total Violations
11
Violation Types
9 serious, 2 other-than-serious
Initial Penalties
$2,850
Penalties on Record
$1,425
Site Address
303 W Oak Street, Norristown, PA 19401
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (8 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.124
General Requirements for Dipping and Coating Operations
OSHA citation code: 19100124 G02
Serious11$750$375Nov 5, 2010Nov 11, 2010Apr 28, 2011
010021910.126
Additional requirements for special dipping and coating operations
OSHA citation code: 19100126 E
Serious11$600$300Nov 23, 2010Nov 11, 2010Apr 28, 2011
01003A1910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious11$750$375Nov 16, 2010Nov 11, 2010Apr 28, 2011
01003B1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01 I
Serious11$0$0Nov 16, 2010Nov 11, 2010Apr 28, 2011
01003C1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Serious11$0$0Nov 16, 2010Nov 11, 2010Apr 28, 2011
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious11$750$375Nov 16, 2010Nov 11, 2010Apr 28, 2011
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious31$0$0Nov 23, 2010Nov 11, 2010Apr 28, 2011
01004C1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious41$0$0Nov 16, 2010Nov 11, 2010Apr 28, 2011

Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 23, 2010Referral (C) · Partial scope, Safety#312980378$2,1756 viol.

Inspection #312980378

Dates

Opened
Jun 23, 2010
Closing Conference Date
Jun 23, 2010
Final Order
Apr 28, 2011
Closed
Apr 16, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3
Related Activity
1 referral

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$5,400
Penalties on Record
$2,175
Site Address
303 W Oak Street, Norristown, PA 19401
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 A04
Serious63$750$375Nov 9, 2010-Apr 28, 2011
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious13$450$225Oct 7, 2010-Apr 28, 2011
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious13$1,500$750Nov 9, 2010-Apr 28, 2011
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Serious33$600$300Nov 9, 2010-Apr 28, 2011
01007A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious13$1,050$525Nov 9, 2010-Apr 28, 2011
01007B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious33$1,050$0Nov 9, 2010-Apr 28, 2011
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $2,625
1910.1200Hazard Communication4 citations · $375
1910.124General Requirements for Dipping and Coating Operations3 citations · $375

Industry comparison

Violations per inspection
This employer3.3
Industry average3.3
Penalties per inspection
This employer$1,700
Industry average$2,307

Fabricated Metal Product Manufacturing, 47,300 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in NORRISTOWN, PA

All employers in NORRISTOWN →