Skip to content
SafetyRecord logoSafetyRecord
HACKETTSTOWN FIRE DEPARTMENT/ MOORE STREET STATION
$0
penalties
16
viol.
4
insp.

HACKETTSTOWN FIRE DEPARTMENT/ MOORE STREET STATION

110 MOORE STREET, HACKETTSTOWN, NJ 07840NAICS 922160

Inspections
4
Jan 2011 to Feb 2011 · 4 safety, 0 health
Violations
16
across 4 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 8, 2011Follow-Up (F) · Partial scope, Safety#315504563$00 viol.

Inspection #315504563

Dates

Opened
Feb 8, 2011
Closing Conference Date
Feb 8, 2011
Closed
Apr 29, 2011

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
86

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
110 Moore Street, Hackettstown, NJ 07840
Industry
922160

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 8, 2011Planned (H) · Complete scope, Safety#315233221$04 viol.

Inspection #315233221

Dates

Opened
Feb 8, 2011
Closing Conference Date
Feb 8, 2011
Closed
Apr 29, 2011

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
86

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
110 Moore Street, Hackettstown, NJ 07840
Industry
922160

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001100006
OSHA citation code: 100006 A01
Serious66$0$0Apr 20, 2011--
01002100007
OSHA citation code: 100007 B01
Serious116$0$0Apr 20, 2011--
01003100008
OSHA citation code: 100008 B
Serious11$0$0Apr 20, 2011--
01004100009
OSHA citation code: 100009 A
Serious22$0$0Apr 20, 2011--
Jan 31, 2011Follow-Up (F) · Partial scope, Safety#315462192$00 viol.

Inspection #315462192

Dates

Opened
Jan 31, 2011
Closing Conference Date
Jan 31, 2011
Closed
Mar 30, 2011

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
86

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
110 Moore Street, Hackettstown, NJ 07840
Industry
922160

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 31, 2011Planned (H) · Complete scope, Safety#315285692$012 viol.

Inspection #315285692

Dates

Opened
Jan 31, 2011
Closing Conference Date
Jan 31, 2011
Closed
Mar 30, 2011

Inspection

Advance Notice
Yes
Owner Type
Local government
Union Status
No
Number of Employees
86

Violations and Penalties

Total Violations
12
Violation Types
8 serious, 4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
110 Moore Street, Hackettstown, NJ 07840
Industry
922160

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.176
Handling Materials - General
OSHA citation code: 19100176 A
Serious440$0$0Apr 20, 2011--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious140$0$0Mar 21, 2011--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious140$0$0Mar 21, 2011--
010041910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01 II
Serious140$0$0Mar 21, 2011--
010051910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious2-$0$0Mar 21, 2011--
010061910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 II
Serious4140$0$0Mar 21, 2011--
010071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 G01 IV
Serious310$0$0Mar 21, 2011--
010081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 III
Serious15$0$0Mar 21, 2011--
020011910.38
Emergency Action Plans
OSHA citation code: 19100038 B01
Other140$0$0Mar 21, 2011--
020021910.39
Fire Prevention Plans
OSHA citation code: 19100039 B
Other140$0$0Mar 21, 2011--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other140$0$0Mar 21, 2011--
020041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other140$0$0Mar 21, 2011--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.303Electrical - General Requirements3 citations · $0
1910.157Portable Fire Extinguishers2 citations · $0
1000081 citation · $0

Industry comparison

Violations per inspection
This employer4.0
Industry average2.1
Penalties per inspection
This employer$0
Industry average$841

Public Administration, 17,093 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in HACKETTSTOWN, NJ

All employers in HACKETTSTOWN →