Skip to content
SafetyRecord logoSafetyRecord
BYRD TECHNOLOGIES DBA MARQUIPT
$14,844
penalties
21
viol.
2
insp.

BYRD TECHNOLOGIES DBA MARQUIPT

3100 SW 10TH ST., POMPANO BEACH, FL 33069NAICS 339999 All Other Miscellaneous Manufacturing

Inspections
2
Jul 2011 to Sep 2011 · 1 safety, 1 health
Violations
21
across 2 inspections
Penalties on record
$14,844
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 6

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 19, 2011Referral (C) · Partial scope, Health#315356626$02 viol.

Inspection #315356626

Dates

Opened
Sep 19, 2011
Closing Conference Date
Sep 22, 2011
Closed
Apr 24, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
37
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
3100 Sw 10th St., Pompano Beach, FL 33069
Industry
339999 All Other Miscellaneous Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC110.647mg/m³
Particulates not otherwise regulated (Respirable Fraction)110.647mg/m³
Sample WeightQC10.181mg
Silica, Crystalline Quartz (Respirable Fraction)10%

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Other12$0$0Jan 5, 2012--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other12$0$0Nov 24, 2011--
Jul 8, 2011Planned (H) · Complete scope, Safety#315354597$14,84419 viol.

Inspection #315354597

Dates

Opened
Jul 8, 2011
Closing Conference Date
Sep 15, 2011
Closed
Oct 11, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
37

Violations and Penalties

Total Violations
19
Violation Types
15 serious, 4 other-than-serious
Initial Penalties
$37,100
Penalties on Record
$14,844
Site Address
3100 Sw 10th St., Pompano Beach, FL 33069
Industry
339999 All Other Miscellaneous Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (19 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 D01
Serious112$2,800$1,120Dec 6, 2011--
010021910.106
Flammable Liquids
OSHA citation code: 19100106 E09 III
Serious37$0$0Nov 29, 2011--
010031910.184
Slings
OSHA citation code: 19100184 E01
Serious12$2,100$840Nov 29, 2011--
010041910.184
Slings
OSHA citation code: 19100184 I01
Serious12$2,100$840Nov 29, 2011--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$2,800$1,120Dec 6, 2011--
010061910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious21$2,100$840Dec 6, 2011--
010071910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious12$2,800$1,120Dec 6, 2011--
010081910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious22$2,800$1,120Dec 6, 2011--
010091910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 IV
Serious22$2,800$1,120Nov 29, 2011--
010101910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious22$3,500$1,404Dec 6, 2011--
010111910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious12$2,800$1,120Dec 6, 2011--
010121910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious22$2,100$840Nov 29, 2011--
010131910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious46$2,800$1,120Nov 29, 2011--
010141910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 X
Serious12$2,800$1,120Nov 29, 2011--
010151910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious34$2,800$1,120Dec 6, 2011--
020011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A04
Other215$0$0Dec 6, 2011--
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L06
Other215$0$0Dec 6, 2011--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other24$0$0Nov 29, 2011--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIIB
Other47$0$0Nov 29, 2011--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses4 citations · $4,764
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $2,240
1910.178Powered Industrial Trucks2 citations · $0

Chemical exposure sampling

Samples
4
Substances
4
Inspections
1

Industry comparison

Violations per inspection
This employer10.5
Industry average2.8
Penalties per inspection
This employer$7,422
Industry average$1,960

Miscellaneous Manufacturing, 10,235 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: all other miscellaneous manufacturing reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 18.5%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in POMPANO BEACH, FL

All employers in POMPANO BEACH →