ALFA LAVAL, INC.
10470 DEER TRAIL DRIVE, HOUSTON, TX 77038 · NAICS 332410 Power Boiler and Heat Exchanger Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Nov 16, 2022#346345614Nov 16, 2022Complaint (B) · Partial scope, Safety#346345614$00 viol.0 violations$0 in penalties
Inspection #346345614
Dates
- Opened
- Nov 16, 2022
- Closing Conference Date
- Nov 16, 2022
- Closed
- Feb 1, 2023
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 80
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 10470 Deer Trail Drive, Houston, TX 77038
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Jan 11, 2018#342875689Jan 11, 2018Follow-Up (F) · Partial scope, Safety#342875689$00 viol.0 violations$0 in penalties
Inspection #342875689
Dates
- Opened
- Jan 11, 2018
- Closing Conference Date
- Jan 11, 2018
- Closed
- Jan 11, 2018
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 100
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 10470 Deer Trail Drive, Houston, TX 77038
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Jan 11, 2018#342872702Jan 11, 2018Follow-Up (F) · Partial scope, Health#342872702$00 viol.0 violations$0 in penalties
Inspection #342872702
Dates
- Opened
- Jan 11, 2018
- Closing Conference Date
- Jan 11, 2018
- Closed
- Jan 11, 2018
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 100
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 10470 Deer Trail Drive, Houston, TX 77038
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Oct 27, 2015#341017630Oct 27, 2015Complaint (B) · Partial scope, Safety#341017630$98,6307 viol.7 violations$98,630 in penalties
Inspection #341017630
Dates
- Opened
- Oct 27, 2015
- Closing Conference Date
- Oct 27, 2015
- Final Order
- May 2, 2016
- Closed
- Oct 27, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 35
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 3 serious, 2 repeat, 2 other-than-serious
- Initial Penalties
- $125,400
- Penalties on Record
- $98,630
- Site Address
- 12249-B Fm 529, Houston, TX 77041
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 5A0001 General Duty Clause, Section 5(a)(1) | Serious | 3 | 10 | $7,000 | $4,900 | Apr 28, 2016 | - | May 2, 2016 |
| 01002 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 B01 | Serious | 1 | 2 | $4,400 | $3,080 | Apr 28, 2016 | - | May 2, 2016 |
| 01003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 II | Serious | 2 | 1 | $5,500 | $3,850 | Apr 28, 2016 | - | May 2, 2016 |
| 02001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Repeat | 1 | 12 | $38,500 | $30,800 | Aug 1, 2016 | - | May 2, 2016 |
| 02002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Repeat | 4 | 3 | $70,000 | $56,000 | Oct 31, 2016 | - | May 2, 2016 |
| 03001 | 1910.184 Slings OSHA citation code: 19100184 E01 | Other | 2 | 2 | $0 | $0 | Apr 28, 2016 | - | May 2, 2016 |
| 03002 | 1910.184 Slings OSHA citation code: 19100184 E03 I | Other | 1 | 10 | $0 | $0 | Apr 28, 2016 | - | May 2, 2016 |
Oct 27, 2015#341017457Oct 27, 2015Complaint (B) · Partial scope, Health#341017457$31,0307 viol.7 violations$31,030 in penalties
Inspection #341017457
Dates
- Opened
- Oct 27, 2015
- Closing Conference Date
- Oct 27, 2015
- Final Order
- May 2, 2016
- Closed
- Jun 3, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 35
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 5 serious, 1 repeat, 1 other-than-serious
- Initial Penalties
- $47,300
- Penalties on Record
- $31,030
- Site Address
- 12249-B Fm 529, Houston, TX 77041
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 5A0001 General Duty Clause, Section 5(a)(1) | Serious | 1 | 2 | $5,500 | $3,850 | May 27, 2016 | - | May 2, 2016 |
| 01002A | 1910.124 General Requirements for Dipping and Coating Operations OSHA citation code: 19100124 G02 | Other | 1 | 5 | $4,400 | $1,000 | May 6, 2016 | - | May 2, 2016 |
| 01003 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 2 | 8 | $5,500 | $3,850 | May 27, 2016 | - | May 2, 2016 |
| 01004A | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Serious | 1 | 2 | $5,500 | $3,850 | Apr 28, 2016 | - | May 2, 2016 |
| 01004B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Serious | 1 | 2 | $0 | $0 | Apr 28, 2016 | - | May 2, 2016 |
| 01005 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G08 | Serious | 1 | 35 | $4,400 | $3,080 | Apr 28, 2016 | - | May 2, 2016 |
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Repeat | 1 | 35 | $22,000 | $15,400 | Apr 28, 2016 | - | May 2, 2016 |
Nov 21, 2008#312646334Nov 21, 2008Complaint (B) · Complete scope, Health#312646334$9,25012 viol.12 violations$9,250 in penalties
Inspection #312646334
Dates
- Opened
- Nov 21, 2008
- Closing Conference Date
- Dec 17, 2008
- Closed
- Jun 5, 2009
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 28
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 5 serious, 7 other-than-serious
- Initial Penalties
- $9,250
- Penalties on Record
- $9,250
- Site Address
- 12249-B Fm 529, Houston, TX 77041
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (8 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 1 | 2 | $2,250 | $2,250 | Dec 30, 2008 | - | - |
| 01002 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | 2 | $2,250 | $2,250 | Dec 30, 2008 | - | - |
| 01003 | 1910.184 Slings OSHA citation code: 19100184 I09 III | Serious | 2 | 2 | $2,250 | $2,250 | Dec 23, 2008 | - | - |
| 01004A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 2 | 1 | $2,500 | $2,500 | Dec 23, 2008 | - | - |
| 01004B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 2 | 1 | $0 | $0 | Dec 23, 2008 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Other | 1 | 1 | $0 | $0 | Dec 30, 2008 | - | - |
| 02002 | 1904.32 Annual Summary OSHA citation code: 19040032 B03 | Other | 1 | 3 | $0 | $0 | Dec 23, 2008 | - | - |
| 02003 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C02 | Other | 2 | 2 | $0 | $0 | Dec 23, 2008 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 2008 to 2022. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Fabricated Metal Product Manufacturing, 47,182 employers with OSHA inspections. Arithmetic from DOL records.