Skip to content
SafetyRecord logoSafetyRecord
STI INTERNATIONAL INCORPORATED
$20,440
penalties
18
viol.
4
insp.

STI INTERNATIONAL INCORPORATED

114 HALMAR COVE, GEORGETOWN, TX 78626NAICS 332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Inspections
4
Nov 2009 to Feb 2016 · 2 safety, 2 health
Violations
18
across 4 inspections
Penalties on record
$20,440
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 1Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 10, 2016Planned (H) · Complete scope, Safety#341255032$7,5006 viol.

Inspection #341255032

Dates

Opened
Feb 10, 2016
Closing Conference Date
Feb 10, 2016
Final Order
Jun 10, 2016
Closed
Jun 13, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
95

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 repeat
Initial Penalties
$14,630
Penalties on Record
$7,500
Site Address
114 Halmar Cove, Georgetown, TX 78628
Industry
332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$3,850$2,000May 10, 2016-Jun 10, 2016
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02
Serious33$2,310$1,200May 18, 2016-Jun 10, 2016
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04
Serious33$0$0May 18, 2016-Jun 10, 2016
01003A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Serious19$2,310$1,200May 10, 2016-Jun 10, 2016
01003B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious513$0$0May 10, 2016-Jun 10, 2016
020011910.1200
Hazard Communication
OSHA citation code: 19101200 F06 II
Repeat36$6,160$3,100May 10, 2016-Jun 10, 2016
Mar 14, 2011Complaint (B) · Partial scope, Health#314306465$7,1404 viol.

Inspection #314306465

Dates

Opened
Mar 14, 2011
Closing Conference Date
Mar 14, 2011
Closed
Oct 1, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$10,200
Penalties on Record
$7,140
Site Address
114 Halmar Cove, Georgetown, TX 78626
Industry
332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Aluminum (as Al), Metal (Total Dust)10.225mg/m³
Gravimetric DeterminationQC40.035 - 0.225mg/m³
Lead, Inorganic (as Pb)20mg/m³
Sample WeightQC40.03 - 0.188mg
Sodium Hydroxide10.035mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious11$2,400$1,680Jul 12, 2011--
010021910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious22$3,600$2,520Jul 12, 2011--
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious11$2,400$1,680Jul 12, 2011--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 F08
Serious21$1,800$1,260Jul 12, 2011--
Mar 12, 2011Complaint (B) · Partial scope, Safety#314306762$4,9002 viol.

Inspection #314306762

Dates

Opened
Mar 12, 2011
Closing Conference Date
Mar 12, 2011
Closed
May 18, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
90
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$7,000
Penalties on Record
$4,900
Site Address
114 Halmar Cove, Georgetown, TX 78628
Industry
332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious24$4,900$3,450Apr 28, 2011--
010021910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 C02 II
Other11$2,100$1,450May 2, 2011--
Nov 18, 2009Planned (H) · Complete scope, Health#312853914$9006 viol.

Inspection #312853914

Dates

Opened
Nov 18, 2009
Closing Conference Date
Nov 18, 2009
Closed
Dec 14, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$1,500
Penalties on Record
$900
Site Address
114 Halmar Cove, Georgetown, TX 78628
Industry
332994 Small Arms, Ordnance, and Ordnance Accessories Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Serious160$750$450Dec 8, 2009--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious11$750$450Dec 8, 2009--
020011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Other135$0$0Dec 8, 2009--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Other11$0$0Dec 10, 2009--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other135$0$0Dec 8, 2009--
020041910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other15$0$0Dec 8, 2009--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.303Electrical - General Requirements3 citations · $2,880
1910.1200Hazard Communication3 citations · $4,360
1910.134Respiratory Protection3 citations · $4,200

Chemical exposure sampling

Samples
12
Substances
5
Inspections
1

Industry comparison

Violations per inspection
This employer4.5
Industry average3.3
Penalties per inspection
This employer$5,110
Industry average$2,308

Fabricated Metal Product Manufacturing, 47,284 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in GEORGETOWN, TX

All employers in GEORGETOWN →