TALLABOA TANK & FABRICATORS INC
$7,700
penalties
26
viol.
3
insp.

TALLABOA TANK & FABRICATORS INC

CAR 337 KM 2 FINAL, PENUELAS, PR 00624NAICS 332420 Metal Tank (Heavy Gauge) Manufacturing

Inspections
3
Apr 1999 to Apr 2016 · 3 safety, 0 health
Violations
26
across 3 inspections
Penalties on record
$7,700
latest amounts in DOL records
By classification
Serious 18Willful 0Repeat 1Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 5, 2016Complaint (B) · Partial scope, Safety#341388940$7,70026 viol.

Inspection #341388940

Dates

Opened
Apr 5, 2016
Closing Conference Date
May 25, 2016
Final Order
Aug 5, 2016
Closed
Apr 17, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15
Related Activity
1 complaint

Violations and Penalties

Total Violations
26
Violation Types
18 serious, 1 repeat, 7 other-than-serious
Initial Penalties
$20,375
Penalties on Record
$7,700
Site Address
Carr 127 No 631, Penuelas, PR 00624
Industry
332420 Metal Tank (Heavy Gauge) Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (16 of 26 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010016
OSHA citation code: 6 A
Serious115$1,000$700Jul 13, 2016-Aug 5, 2016
010026
OSHA citation code: 6 A
Serious11$800$560Jul 19, 2016-Aug 5, 2016
01003A1910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious315$600$1,400Jul 13, 2016-Aug 5, 2016
01003B1910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious215$800$0Jul 13, 2016-Aug 5, 2016
01003C1910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious115$800$0Jul 13, 2016-Aug 5, 2016
01003D1910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious115$2,000$0Jul 13, 2016-Aug 5, 2016
01004A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Serious24$1,400$980-Aug 5, 2016
01004B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q01
Serious14$1,400$0Jul 19, 2016-Aug 5, 2016
01005A1910.180
Crawler Locomotive and Truck Cranes
OSHA citation code: 19100180 D03
Serious11$1,400$980Jul 19, 2016-Aug 5, 2016
01005B1910.180
Crawler Locomotive and Truck Cranes
OSHA citation code: 19100180 D04
Serious11$1,400$0Jul 19, 2016-Aug 5, 2016
01007A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious11$600$420Jul 13, 2016-Aug 5, 2016
01007B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$600$0Jul 13, 2016-Aug 5, 2016
01008A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Serious115$600$840Aug 2, 2016-Aug 5, 2016
01008B1910.1200
Hazard Communication
OSHA citation code: 19101200 F06
Serious115$600$0Jul 13, 2016-Aug 5, 2016
01008C1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious115$375$0Jul 13, 2016-Aug 5, 2016
01008D1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious115$600$0Jul 19, 2016-Aug 5, 2016

Showing the 16 violations listed first by citation identifier. This inspection has 26 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 27, 2005Planned (H) · Complete scope, Safety#306668708$00 viol.

Inspection #306668708

Dates

Opened
Oct 27, 2005
Closing Conference Date
Oct 27, 2005
Closed
Oct 28, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Car 337 Km 2 Final, Penuelas, PR 00624
Industry
332420 Metal Tank (Heavy Gauge) Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 15, 1999Planned (H) · Complete scope, Safety#300425246$00 viol.

Inspection #300425246

Dates

Opened
Apr 15, 1999
Closing Conference Date
Apr 15, 1999
Closed
Apr 21, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Rd 337 Km 3.7 Bo Tallaboa, Penuelas, PR 00624
Industry
332420 Metal Tank (Heavy Gauge) Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication5 citations · $840
1910.101Compressed Gases (General Requirements)4 citations · $1,400
63 citations · $1,540

Industry comparison

Violations per inspection
This employer8.7
Industry average3.3
Penalties per inspection
This employer$2,567
Industry average$2,308

Fabricated Metal Product Manufacturing, 47,284 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: metal tank (heavy gauge) manufacturing reported 3.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.7%; NAICS 33242 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PENUELAS, PR

All employers in PENUELAS →