AIR FORCE
BUILDING 6264, JBER, AK 99506 · NAICS 928110
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Nov 14, 2017#342774171Nov 14, 2017Planned (H) · Complete scope, Safety#342774171$08 viol.8 violations$0 in penalties
Inspection #342774171
Dates
- Opened
- Nov 14, 2017
- Closing Conference Date
- Nov 15, 2017
- Final Order
- Apr 9, 2018
- Closed
- Apr 16, 2018
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 133
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 3 serious, 5 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 673 Air Base Wing 10441 Kuter Ave, Jber, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Serious | 1 | 3 | $0 | $0 | May 1, 2018 | - | Apr 9, 2018 |
| 01002 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 15 | $0 | $0 | May 1, 2018 | - | Apr 9, 2018 |
| 01003 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 2 | 2 | $0 | $0 | May 1, 2018 | - | Apr 9, 2018 |
| 02001A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B07 III | Other | 1 | 3 | $0 | $0 | May 1, 2018 | - | Apr 9, 2018 |
| 02001B | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 II | Other | 7 | 15 | $0 | $0 | May 1, 2018 | - | Apr 9, 2018 |
Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Nov 14, 2017#342774023Nov 14, 2017Planned (H) · Complete scope, Safety#342774023$00 viol.0 violations$0 in penalties
Inspection #342774023
Dates
- Opened
- Nov 14, 2017
- Closing Conference Date
- Nov 15, 2017
- Closed
- Mar 19, 2018
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 47
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 673 Force Support Squadron Bldg 726, Jber, AK 99506
- Industry
- 812320 Drycleaning and Laundry Services (except Coin-Operated)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Oct 5, 2017#342683539Oct 5, 2017Complaint (B) · Partial scope, Health#342683539$01 viol.1 violation$0 in penalties
Inspection #342683539
Dates
- Opened
- Oct 5, 2017
- Closing Conference Date
- Oct 23, 2017
- Final Order
- Nov 20, 2017
- Closed
- Nov 29, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 70
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6136 Doolittle, Jber, AK 99506
- Industry
- 485113 Bus and Other Motor Vehicle Transit Systems
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.1001 Asbestos OSHA citation code: 19101001 J03 III | Other | 1 | 16 | $0 | $0 | Nov 22, 2017 | - | Nov 20, 2017 |
Aug 16, 2017#342554656Aug 16, 2017Follow-Up (F) · Partial scope, Health#342554656$00 viol.0 violations$0 in penalties
Inspection #342554656
Dates
- Opened
- Aug 16, 2017
- Closing Conference Date
- Aug 16, 2017
- Closed
- Sep 8, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 50
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Maintenance Group Propulsion Flight, Jber, AK 99506
- Industry
- 336412 Aircraft Engine and Engine Parts Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Jan 3, 2017#342008315Jan 3, 2017Planned (H) · Complete scope, Safety#342008315$00 viol.0 violations$0 in penalties
Inspection #342008315
Dates
- Opened
- Jan 3, 2017
- Closing Conference Date
- Jan 4, 2017
- Closed
- Jan 9, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Maintenance Group Metals Technology Section, Jber, AK 99506
- Industry
- 336413 Other Aircraft Parts and Auxiliary Equipment Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jan 3, 2017#342007309Jan 3, 2017Planned (H) · Complete scope, Safety#342007309$04 viol.4 violations$0 in penalties
Inspection #342007309
Dates
- Opened
- Jan 3, 2017
- Closing Conference Date
- Jan 4, 2017
- Final Order
- Feb 3, 2017
- Closed
- Feb 6, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 32
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 repeat
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 8574 Sijan Ave, Jber, AK 99506
- Industry
- 488119 Other Airport Operations
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.244 Other Portable Tools and Equipment OSHA citation code: 19100244 A01 II | Serious | 1 | 4 | $0 | $0 | Feb 7, 2017 | - | Feb 3, 2017 |
| 01002 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B07 IV | Serious | 3 | 4 | $0 | $0 | Feb 7, 2017 | - | Feb 3, 2017 |
| 01003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 IV B | Serious | 1 | 4 | $0 | $0 | Feb 7, 2017 | - | Feb 3, 2017 |
| 02001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 II | Repeat | 2 | 4 | $0 | $0 | Feb 7, 2017 | - | Feb 3, 2017 |
Apr 15, 2014#339903635Apr 15, 2014Follow-Up (F) · Partial scope, Health#339903635$01 viol.1 violation$0 in penalties
Inspection #339903635
Dates
- Opened
- Apr 15, 2014
- Closing Conference Date
- Apr 15, 2014
- Final Order
- Nov 6, 2014
- Closed
- Nov 6, 2014
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 673 Force Support Squadron Bldg 726, Jber, AK 99506
- Industry
- 812320 Drycleaning and Laundry Services (except Coin-Operated)
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 02001 | 1960.26 Conduct of inspections OSHA citation code: 19600026 C03 | Other | 1 | 40 | $0 | $0 | Oct 16, 2014 | - | Nov 6, 2014 |
Apr 15, 2014#339897258Apr 15, 2014Follow-Up (F) · Partial scope, Safety#339897258$03 viol.3 violations$0 in penalties
Inspection #339897258
Dates
- Opened
- Apr 15, 2014
- Closing Conference Date
- Apr 15, 2014
- Final Order
- Sep 17, 2014
- Closed
- Oct 2, 2014
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 14
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 1 serious, 1 repeat, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 773 Logistics Readiness Squadron 6136 Doolittle Ave, Jber, AK 99506
- Industry
- 485999 All Other Transit and Ground Passenger Transportation
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1960.30 Abatement of unsafe or unhealthful working conditions OSHA citation code: 19600030 A | Serious | 2 | 14 | $0 | $0 | Aug 26, 2014 | - | Sep 17, 2014 |
| 02001 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Repeat | 2 | 14 | $0 | $0 | Aug 26, 2014 | - | Sep 17, 2014 |
| 03001 | 1903.19 Abatement Verification OSHA citation code: 19030019 C01 | Other | 1 | 14 | $0 | $0 | Aug 26, 2014 | - | Sep 17, 2014 |
Jan 21, 2014#339559890Jan 21, 2014Planned (H) · Complete scope, Health#339559890$014 viol.14 violations$0 in penalties
Inspection #339559890
Dates
- Opened
- Jan 21, 2014
- Closing Conference Date
- Jan 23, 2014
- Final Order
- Nov 6, 2014
- Closed
- Nov 6, 2014
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 10 serious, 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 673 Force Support Squadron Bldg 726, Jber, AK 99506
- Industry
- 812320 Drycleaning and Laundry Services (except Coin-Operated)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Serious | 3 | 2 | $0 | $0 | Mar 31, 2014 | - | Mar 6, 2014 |
| 01002 | 1910.23 Ladders OSHA citation code: 19100023 A08 | Serious | 1 | 40 | $0 | $0 | Mar 31, 2014 | - | Mar 6, 2014 |
| 01003 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B01 | Serious | 1 | 40 | $0 | $0 | Mar 31, 2014 | - | Mar 6, 2014 |
| 01004 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B02 | Serious | 2 | 40 | $0 | $0 | Mar 31, 2014 | - | Mar 6, 2014 |
| 01005 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B05 | Serious | 1 | 40 | $0 | $0 | Mar 31, 2014 | - | Mar 6, 2014 |
Showing the 5 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Failure to Abate Penalties2 citations
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|---|---|---|---|---|
| 01001 | #990363 | Oct 15, 2014 | - | - | Nov 6, 2014 |
| 01004 | #990363 | Oct 15, 2014 | - | - | Nov 6, 2014 |
Dec 9, 2013#339524795Dec 9, 2013Planned (H) · Complete scope, Safety#339524795$05 viol.5 violations$0 in penalties
Inspection #339524795
Dates
- Opened
- Dec 9, 2013
- Closing Conference Date
- Dec 17, 2013
- Final Order
- Mar 19, 2014
- Closed
- Apr 30, 2014
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 773 Civil Engineering Squardon 5329 Kenny Ave, Jber, AK 99506
- Industry
- 921190
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Serious | 1 | 3 | $0 | $0 | Mar 31, 2014 | - | Mar 19, 2014 |
| 01002 | 1910.23 Ladders OSHA citation code: 19100023 A02 | Serious | 1 | 3 | $0 | $0 | Mar 31, 2014 | - | Mar 19, 2014 |
| 01003 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B02 | Serious | 3 | 3 | $0 | $0 | Mar 31, 2014 | - | Mar 19, 2014 |
| 01004 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F01 IV | Serious | 2 | 3 | $0 | $0 | Mar 31, 2014 | - | Mar 19, 2014 |
| 01005 | 1960.8 Agency Responsibilities OSHA citation code: 19600008 A | Serious | 10 | 3 | $0 | $0 | Feb 28, 2014 | - | Mar 19, 2014 |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
20 inspections, 2013 to 2020. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Public Administration, 1,891 employers with OSHA inspections. Arithmetic from DOL records.