Skip to content
SafetyRecord logoSafetyRecord
NEO PRODUCTS CORPORATION
$15,255
penalties
48
viol.
17
insp.

NEO PRODUCTS CORPORATION

99 RECORD DRIVE, HENDERSON, TN 38340

Inspections
17
Aug 1985 to Jun 2018 · 12 safety, 5 health
Violations
48
across 17 inspections
Penalties on record
$15,255
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 2Other 31

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 12, 2018Follow-Up (F) · Partial scope, Safety#343221750$00 viol.

Inspection #343221750

Dates

Opened
Jun 12, 2018
Closing Conference Date
Jun 12, 2018
Closed
Jun 27, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
67

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 15, 2017Planned (H) · Complete scope, Safety#342550175$9,6005 viol.

Inspection #342550175

Dates

Opened
Aug 15, 2017
Closing Conference Date
Aug 15, 2017
Final Order
Oct 12, 2017
Closed
Mar 1, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
61

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 2 repeat, 2 other-than-serious
Initial Penalties
$12,000
Penalties on Record
$9,600
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 I D
Serious11$2,100$1,680Oct 12, 2017-Oct 12, 2017
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Repeat22$4,200$3,360Oct 12, 2017-Oct 12, 2017
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Repeat104$4,800$3,840Feb 28, 2018-Oct 12, 2017
030011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other15$300$240Nov 11, 2017-Oct 12, 2017
03002TDLWD
OSHA citation code: TDLWD RULE 800-01-03-.03(27)(B)1
Other41$600$480Nov 11, 2017-Oct 12, 2017
Feb 8, 2017Programmed Related (I) · Complete scope, Health#342090313$03 viol.

Inspection #342090313

Dates

Opened
Feb 8, 2017
Closing Conference Date
Feb 8, 2017
Final Order
Mar 29, 2017
Closed
Mar 23, 2017

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
64

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 IV
Other18$0$0Apr 10, 2017-Mar 29, 2017
01001B1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 H02 I B
Other18$0$0Apr 10, 2017-Mar 29, 2017
01001C1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 H02 I D
Other18$0$0Apr 10, 2017-Mar 29, 2017
Oct 15, 2012Referral (C) · Partial scope, Health#316803659$00 viol.

Inspection #316803659

Dates

Opened
Oct 15, 2012
Closing Conference Date
Oct 31, 2012
Closed
Nov 15, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
55
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Oct 11, 2012Planned (H) · Complete scope, Safety#316776830$3,60013 viol.

Inspection #316776830

Dates

Opened
Oct 11, 2012
Closing Conference Date
Oct 11, 2012
Closed
Jan 9, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
55

Violations and Penalties

Total Violations
13
Violation Types
7 serious, 6 other-than-serious
Initial Penalties
$4,800
Penalties on Record
$3,600
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IA
Serious12$1,400$1,000Nov 21, 2012--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C08
Serious11$0$0Nov 28, 2012--
01001C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 IID
Serious11$0$0Nov 21, 2012--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D03
Serious22$1,400$1,050Nov 21, 2012--
01003A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$1,400$1,050Nov 28, 2012--

Showing the 5 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 14, 2009Planned (H) · Partial scope, Safety#313661902$03 viol.

Inspection #313661902

Dates

Opened
Aug 14, 2009
Closing Conference Date
Aug 14, 2009
Closed
Mar 5, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
64

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$1,050
Penalties on Record
$0
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other41$1,050$0Oct 14, 2009--
020011910.23
Ladders
OSHA citation code: 19100023 E01
Other11$0$0Sep 27, 2009--
020021910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 II
Other11$0$0Sep 27, 2009--
Aug 14, 2009Planned (H) · Complete scope, Health#313661886$03 viol.

Inspection #313661886

Dates

Opened
Aug 14, 2009
Closing Conference Date
Aug 14, 2009
Closed
Sep 15, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
64

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332116

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Other12$0$0Oct 2, 2009--
01002A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other12$0$0Sep 6, 2009--
01002B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Other12$0$0Sep 6, 2009--
May 4, 2006Planned (H) · Complete scope, Safety#309926509$7503 viol.

Inspection #309926509

Dates

Opened
May 4, 2006
Closing Conference Date
May 4, 2006
Closed
Jul 5, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
79

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$750
Penalties on Record
$750
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious11$750$750Jun 30, 2006--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other11$0$0Jun 30, 2006--
020021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other11$0$0Jun 30, 2006--
May 6, 2003Planned (H) · Complete scope, Safety#306134040$8259 viol.

Inspection #306134040

Dates

Opened
May 6, 2003
Closing Conference Date
May 6, 2003
Closed
Jul 23, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
74

Violations and Penalties

Total Violations
9
Violation Types
3 serious, 6 other-than-serious
Initial Penalties
$1,100
Penalties on Record
$825
Site Address
99 Record Drive, Henderson, TN 38340
Industry
332919 Other Metal Valve and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious11$500$375Jul 6, 2003--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$0$0Jul 6, 2003--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious21$600$450Jun 29, 2003--
020011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B04
Other11$0$0Jun 29, 2003--
02002A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other11$0$0Jul 6, 2003--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 16, 1991Planned (H) · Complete scope, Safety#111071312$3204 viol.

Inspection #111071312

Dates

Opened
Sep 16, 1991
Closing Conference Date
Sep 16, 1991
Closed
Jan 13, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$320
Penalties on Record
$320
Site Address
99 Record Drive, Henderson, TN 38340
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious11$160$160Sep 30, 1991--
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious11$160$160Sep 30, 1991--
020011910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J03 IV
Other11$0$0Oct 3, 1991--
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other11$0$0Sep 30, 1991--
Inspections 1 to 10 of 17, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)7 citations · $8,250
1910.147Control of Hazardous Energy (Lockout/Tagout)5 citations · $2,290
1910.1200Hazard Communication4 citations · $150

Other inspected employers in HENDERSON, TN

All employers in HENDERSON →