Skip to content
SafetyRecord logoSafetyRecord
ACCUTHERM INC.
$16,080
penalties
18
viol.
4
insp.

ACCUTHERM INC.

RT. L47 & STATION RD., FRANKLINVILLE, NJ 08322

Inspections
4
Jan 1988 to Apr 1991 · 0 safety, 4 health
Violations
18
across 4 inspections
Penalties on record
$16,080
latest amounts in DOL records
By classification
Serious 12Willful 4Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 26, 1991Follow-Up (F) · Complete scope, Health#17783218$00 viol.

Inspection #17783218

Dates

Opened
Apr 26, 1991
Closing Conference Date
Apr 26, 1991
Closed
Apr 26, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Rt. L47 & Station Rd., Franklinville, NJ 08322
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 24, 1989Referral (C) · Complete scope, Health#106740541$00 viol.

Inspection #106740541

Dates

Opened
May 24, 1989
Closing Conference Date
Jul 19, 1989
Closed
Aug 14, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Rt. L47 & Station Rd., Franklinville, NJ 08322
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Apr 3, 1989Follow-Up (F) · Complete scope, Health#17797432$15,0004 viol.

Inspection #17797432

Dates

Opened
Apr 3, 1989
Closing Conference Date
Jun 22, 1989
Contested
Aug 22, 1989
Final Order
Sep 3, 1990
Closed
May 10, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
4 willful
Initial Penalties
$23,000
Penalties on Record
$15,000
Site Address
Rt. L47 & Station Rd., Franklinville, NJ 08322
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Mercury (Vapor) (as Hg)159P / 6A0 - 0.2mg/m³
Particulates not otherwise regulated (Respirable Fraction)148P / 6A0mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011903.16
Posting of Citations
OSHA citation code: 19030016 A
Willful13$5,000$3,000Aug 22, 1989Aug 22, 1989Sep 3, 1990
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Willful11$9,000$2,000Aug 29, 1989Aug 22, 1989Sep 3, 1990
01002B1910.1000
Air Contaminants
OSHA citation code: 19101000 B01
Willful11$0$5,000Sep 1, 1989Aug 22, 1989Sep 3, 1990
010031910.1000
Air Contaminants
OSHA citation code: 19101000 E
Willful11$9,000$5,000Dec 15, 1989Aug 22, 1989Sep 3, 1990
Jan 11, 1988Complaint (B) · Partial scope, Health#100525211$1,08014 viol.

Inspection #100525211

Dates

Opened
Jan 11, 1988
Closing Conference Date
Apr 21, 1988
Contested
Jun 17, 1988
Final Order
Mar 1, 1989
Closed
May 10, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 complaint, 1 referral

Violations and Penalties

Total Violations
14
Violation Types
12 serious, 2 other-than-serious
Initial Penalties
$2,160
Penalties on Record
$1,080
Site Address
Rt. L47 & Station Rd., Franklinville, NJ 08322
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Mercury (Vapor) (as Hg)84P / 4A0.058 - 0.14mg/m³
Particulates not otherwise regulated (Respirable Fraction)84P / 4A0mg/m³

Violations

Violation list (12 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious11$800$400Jun 9, 1988Jun 17, 1988Mar 1, 1989
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 B01
Serious11$0$0Sep 1, 1988Jun 17, 1988Mar 1, 1989
01001C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Sep 1, 1988Jun 17, 1988Mar 1, 1989
01001D1910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious11$0$0Jun 2, 1988Jun 17, 1988Mar 1, 1989
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$320$160Jun 26, 1988Jun 17, 1988Mar 1, 1989
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Jun 26, 1988Jun 17, 1988Mar 1, 1989
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious11$480$240Jun 2, 1988Jun 17, 1988Mar 1, 1989
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious11$560$280Jul 1, 1989Jun 17, 1988Mar 1, 1989
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious11$0$0Jun 2, 1988Jun 17, 1988Mar 1, 1989
01004C1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious11$0$0Jun 2, 1988Jun 17, 1988Mar 1, 1989
01004D1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious11$0$0Jun 26, 1988Jun 17, 1988Mar 1, 1989
01004E1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious11$0$0Jul 1, 1989Jun 17, 1988Mar 1, 1989

Showing the 12 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties5 citations, $26,830 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 5 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001A#17797432Aug 14, 1989$6,000Aug 25, 1989Sep 9, 1990
01001B#17797432Aug 14, 1989$7,000Aug 25, 1989Sep 9, 1990
01001C#17797432Aug 14, 1989$6,000Aug 25, 1989Sep 9, 1990
01004A#106740541Aug 14, 1989$6,000Aug 25, 1989Sep 9, 1990
01004E#106740541Aug 14, 1989$1,830-Sep 9, 1990
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication5 citations · $280
1910.1000Air Contaminants4 citations · $10,000
1910.219Mechanical Power-Transmission Apparatus2 citations · $160

Chemical exposure sampling

Samples
45
Substances
2
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in FRANKLINVILLE, NJ