Skip to content
SafetyRecord logoSafetyRecord
ACME STEEL PARTITION CO., INC.
$21,630
penalties
64
viol.
2
insp.

ACME STEEL PARTITION CO., INC.

513 PORTER AVENUE, Brooklyn, NY 11222

Inspections
2
Nov 1989 to Feb 1990 · 1 safety, 1 health
Violations
64
across 2 inspections
Penalties on record
$21,630
latest amounts in DOL records
By classification
Serious 45Willful 1Repeat 0Other 18

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 1, 1990Referral (C) · Partial scope, Health#100600733$2,17011 viol.

Inspection #100600733

Dates

Opened
Feb 1, 1990
Closing Conference Date
Jul 19, 1990
Closed
May 7, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
250
Related Activity
1 referral

Violations and Penalties

Total Violations
11
Violation Types
7 serious, 4 other-than-serious
Initial Penalties
$2,400
Penalties on Record
$2,170
Site Address
513 Porter Avenue, Brooklyn, NY 11222
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)110mg/m³
Beryllium and Beryllium Compounds (as Be)100mg/m³
Cadmium Fume (as Cd)110mg/m³
Chromium, Metal and Insoluble Salts110 - 0.0021mg/m³
Cobalt, Metal, Dust and Fume (as Co)110mg/m³
Copper Fume (as Cu)110 - 0.0609mg/m³
Iron Oxide Fume110 - 3.3165mg/m³
Lead, Inorganic (as Pb)110mg/m³
Manganese Fume (as Mn)110 - 0.3427mg/m³
Methyl Chloroform3074.3294 - 433.519ppm
Molybdenum (as Mo), Insoluble Compounds (Total Dust)110mg/m³
Nickel, Metal and Insoluble compounds (as Ni)110mg/m³
Silica, Crystalline Quartz (Respirable Fraction)50%
Vanadium fume (as V2O5)110mg/m³
Zinc Oxide Fume110 - 0.3951mg/m³

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious522$800$560Mar 1, 1991--
010021910.106
OSHA citation code: 19100106 E06 I
Serious13$800$560Oct 1, 1990--
01003A1910.106
OSHA citation code: 19100106 E06 I
Serious13$800$560Oct 1, 1990--
01003B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious28$0$0Oct 1, 1990--
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 A01
Serious18$0$490Oct 30, 1990--
01004B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious1-$0$0Mar 1, 1991--
01004C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious16$0$0Mar 1, 1991--
020011910.22
OSHA citation code: 19100022 A01
Other13$0$0Aug 2, 1990--
020021910.132
General requirements
OSHA citation code: 19100132 C
Other22$0$0Aug 30, 1990--
020031910.1025
Lead
OSHA citation code: 19101025 L01 I
Other13$0$0Oct 30, 1990--
020041910.1025
Lead
OSHA citation code: 19101025 L02 I
Other13$0$0Aug 30, 1990--
Nov 21, 1989Referral (C) · Complete scope, Safety#109883967$19,46053 viol.

Inspection #109883967

Dates

Opened
Nov 21, 1989
Closing Conference Date
Jan 3, 1990
Closed
Feb 5, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
250
Related Activity
1 referral

Violations and Penalties

Total Violations
53
Violation Types
38 serious, 1 willful, 14 other-than-serious
Initial Penalties
$29,700
Penalties on Record
$19,460
Site Address
513 Porter Avenue, Brooklyn, NY 11222
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (25 of 53 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 C
Serious12$500$350Mar 6, 1990--
010021910.23
OSHA citation code: 19100023 C01
Serious110$500$350Mar 13, 1990--
010031910.23
OSHA citation code: 19100023 D01 III
Serious14$400$280Mar 6, 1990--
010041910.36
OSHA citation code: 19100036 B05
Serious16$400$280Feb 15, 1990--
010051910.36
OSHA citation code: 19100036 B06
Serious110$300$210Mar 6, 1990--
010061910.106
OSHA citation code: 19100106 D03 II
Serious110$400$280Mar 13, 1990--
010071910.106
OSHA citation code: 19100106 D04 IV
Serious110$400$280Mar 13, 1990--
010081910.106
OSHA citation code: 19100106 D06 IV
Serious110$400$280Feb 15, 1990--
010091910.106
OSHA citation code: 19100106 E06 II
Serious13$400$280Mar 13, 1990--
010101910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B01
Serious210$600$420Dec 13, 1990--
010111910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B02
Serious110$600$420Mar 13, 1990--
01012A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious310$600$420Mar 13, 1990--
01012B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious14$0$0Dec 13, 1990--
010131910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious13$400$280Mar 13, 1990--
010141910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 F03
Serious310$600$420Mar 13, 1990--
010151910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 F04
Serious310$600$420Mar 13, 1990--
010161910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G01
Serious210$600$420Feb 14, 1990--
010171910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Other310$600$0Feb 15, 1990--
010181910.108
OSHA citation code: 19100108 B01
Serious13$400$280Dec 13, 1990--
010191910.108
OSHA citation code: 19100108 F04
Other13$400$0Feb 20, 1990--
010201910.108
OSHA citation code: 19100108 G06 IV
Other13$400$0Mar 13, 1990--
010211910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious22$400$280Feb 15, 1990--
010231910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious110$800$560Mar 13, 1990--
010241910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious410$800$560Mar 13, 1990--
010251910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 D01
Serious13$300$210Mar 13, 1990--

Showing the 25 violations listed first by citation identifier. This inspection has 53 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials9 citations · $2,800
1910.1066 citations · $2,240
1910.217Mechanical Power Presses5 citations · $8,120

Chemical exposure sampling

Samples
177
Substances
15
Inspections
1

Other inspected employers in Brooklyn, NY