Skip to content
SafetyRecord logoSafetyRecord
ALEXANDER ROOFING, LLC
$5,022
penalties
7
viol.
2
insp.

ALEXANDER ROOFING, LLC

76 EAST 2ND STREET, CHILLICOTHE, OH 45601NAICS 238160 Roofing Contractors

Inspections
2
Aug 2006 to Dec 2018 · 2 safety, 0 health
Violations
7
across 2 inspections
Penalties on record
$5,022
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 19, 2018Planned (H) · Partial scope, Safety#343673364$2,7723 viol.

Inspection #343673364

Dates

Opened
Dec 19, 2018
Closing Conference Date
Jan 14, 2019
Final Order
Feb 21, 2019
Closed
Jul 15, 2020

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$10,532
Penalties on Record
$2,772
Site Address
745 E. 4th St., Chillicothe, OH 45601
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious11$3,880$2,772Feb 6, 2019-Feb 21, 2019
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 I
Serious171$3,880$0-Feb 21, 2019
01001C1926.454
Scaffolding - Training
OSHA citation code: 19260454 A01
Serious11$2,772$0Mar 11, 2019-Feb 21, 2019
Aug 2, 2006Planned (H) · Partial scope, Safety#310134887$2,2504 viol.

Inspection #310134887

Dates

Opened
Aug 2, 2006
Closing Conference Date
Aug 2, 2006
Contested
Oct 4, 2006
Final Order
Jan 18, 2007
Closed
Mar 19, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$4,500
Penalties on Record
$2,250
Site Address
76 East 2nd Street, Chillicothe, OH 45601
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious16$1,500$750Oct 26, 2006Oct 4, 2006Jan 18, 2007
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious44$750$375Sep 13, 2006Oct 4, 2006Jan 18, 2007
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B11
Serious66$1,500$750Sep 13, 2006Oct 4, 2006Jan 18, 2007
010041926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious16$750$375Oct 26, 2006Oct 4, 2006Jan 18, 2007
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements2 citations · $2,772
1926.20General Safety and Health Provisions1 citation · $750
1926.404Electrical - Wiring Design and Protection (Construction)1 citation · $375

Industry comparison

Violations per inspection
This employer3.5
Industry average2.1
Penalties per inspection
This employer$2,511
Industry average$2,528

Specialty Trade Contractors, 551,392 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: roofing contractors reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.7%; NAICS 23816 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in CHILLICOTHE, OH

All employers in CHILLICOTHE →