Skip to content
SafetyRecord logoSafetyRecord
ALLERGAN AMERICA
$1,360
penalties
14
viol.
6
insp.

ALLERGAN AMERICA

CARR. #345 KM. 1.5, HORMIGUEROS, PR 00660

Inspections
6
Oct 1978 to Sep 1993 · 4 safety, 2 health
Violations
14
across 6 inspections
Penalties on record
$1,360
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 8, 1993Referral (C) · Partial scope, Health#119488716$00 viol.

Inspection #119488716

Dates

Opened
Sep 8, 1993
Closing Conference Date
Sep 27, 1993
Closed
Sep 27, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
231
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Carr. #345 Km. 1.5, Hormigueros, PR 00660
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Jun 12, 1989Referral (C) · No Inspection scope, Safety#108115387$00 viol.

Inspection #108115387

Dates

Opened
Jun 12, 1989
Closing Conference Date
Jun 12, 1989
Closed
Jun 12, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
Not recorded
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Carr. #345 Km. 1.5, Hormigueros, PR 00660
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Jan 12, 1989Programmed Other (K) · Partial scope, Health#108483082$1,3609 viol.

Inspection #108483082

Dates

Opened
Jan 12, 1989
Closing Conference Date
Apr 21, 1989
Closed
Sep 11, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
250

Violations and Penalties

Total Violations
9
Violation Types
6 serious, 3 other-than-serious
Initial Penalties
$1,360
Penalties on Record
$1,360
Site Address
Carr. #345 Km. 1.5, Hormigueros, PR 00660
Industry
Not classified in OSHA's inspection record.

Programmed Other Inspection: This inspection record is categorized as a programmed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Ethylene Oxide40.2776 - 5.9054ppm

Violations

Violation list (8 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E05 I
Serious11$0$0Jul 1, 1989--
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F04
Serious11$0$0Jul 7, 1989--
01002A1910.1047
Ethylene Oxide
OSHA citation code: 19101047 C02
Serious12$480$480Jul 30, 1989--
01002B1910.1047
Ethylene Oxide
OSHA citation code: 19101047 F01 I
Serious12$0$0Jul 30, 1989--
010031910.1047
Ethylene Oxide
OSHA citation code: 19101047 E02
Serious11$400$400Jul 3, 1989--
010041910.1047
Ethylene Oxide
OSHA citation code: 19101047 H02
Serious44$480$480Jul 30, 1989--
020011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Other112$0$0Apr 21, 1989--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other13$0$0Apr 21, 1989--

Showing the 8 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 29, 1982Planned (H) · Complete scope, Safety#12163655$01 viol.

Inspection #12163655

Dates

Opened
Nov 29, 1982
Closing Conference Date
Nov 29, 1982
Closed
Dec 10, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
85

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Carr #345 Km 1.5 Bo Lavadero, Hormigueros, PR 00660
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Wiring design and protection
OSHA citation code: 19100304 A02
Other2-$0$0Nov 29, 1982--
Sep 1, 1981Planned (H) · Partial scope, Safety#12157954$03 viol.

Inspection #12157954

Dates

Opened
Sep 1, 1981
Closing Conference Date
Sep 1, 1981
Closed
Jan 19, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
83

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Carr 345 Km 1 5 Bo Lavadero, Hormigueros, PR 00660
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.25
OSHA citation code: 19100025 D010000I
Other1-$0$0Sep 17, 1981--
010021910.37
OSHA citation code: 19100037 I
Other1-$0$0Oct 11, 1981--
010031910.304
Wiring design and protection
OSHA citation code: 19100304 B050000V
Other1-$0$0Sep 12, 1981--
Oct 4, 1978Planned (H) · Complete scope, Safety#12161527$01 viol.

Inspection #12161527

Dates

Opened
Oct 4, 1978
Closing Conference Date
Oct 4, 1978
Closed
May 21, 1979

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
75

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Carr 345 Km 1 5 Bo Taquitas, Hormigueros, PR 00660
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Other1-$0$0Nov 6, 1978--
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection4 citations · $0
1910.1047Ethylene Oxide4 citations · $1,360
1910.304Wiring design and protection2 citations · $0

Chemical exposure sampling

Samples
4
Substances
1
Inspections
1

Other inspected employers in HORMIGUEROS, PR

All employers in HORMIGUEROS →