Skip to content
SafetyRecord logoSafetyRecord
AMERICAN FRAMING INC.
$17,250
penalties
19
viol.
3
insp.

AMERICAN FRAMING INC.

9509 SHELLY KORASNOW LANE, FAIRFAX, VA 22031NAICS 238350 Finish Carpentry Contractors

Inspections
3
Sep 2004 to Feb 2013 · 3 safety, 0 health
Violations
19
across 3 inspections
Penalties on record
$17,250
latest amounts in DOL records
By classification
Serious 15Willful 2Repeat 1Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 13, 2013Planned (H) · Partial scope, Safety#316954296$10,0004 viol.

Inspection #316954296

Dates

Opened
Feb 13, 2013
Closing Conference Date
Feb 13, 2013
Closed
Dec 17, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 willful
Initial Penalties
$16,890
Penalties on Record
$10,000
Site Address
10601 Yorktown Drive, Fairfax, VA 22030
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.50
Medical Services and First Aid (Construction)
OSHA citation code: 19260050 C
Serious112$840$500Dec 20, 2013--
010021926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious18$1,050$500Feb 14, 2013--
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Willful44$7,500$4,500Feb 14, 2013--
020021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Willful36$7,500$4,500Feb 14, 2013--
Dec 6, 2004Planned (H) · Partial scope, Safety#308425800$2,0002 viol.

Inspection #308425800

Dates

Opened
Dec 6, 2004
Closing Conference Date
Dec 6, 2004
Closed
Nov 27, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$2,000
Penalties on Record
$2,000
Site Address
4541 Monmouth Street, Fairfax, VA 22030
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 V
Serious11$1,000$1,000Mar 9, 2005--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious11$1,000$1,000Mar 9, 2005--
Sep 10, 2004Planned (H) · Complete scope, Safety#308178888$5,25013 viol.

Inspection #308178888

Dates

Opened
Sep 10, 2004
Closing Conference Date
Sep 10, 2004
Closed
Dec 19, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
13
Violation Types
11 serious, 1 repeat, 1 other-than-serious
Initial Penalties
$5,250
Penalties on Record
$5,250
Site Address
9509 Shelly Korasnow Lane, Fairfax, VA 22031
Industry
238350 Finish Carpentry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious12$375$375Nov 9, 2004--
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B02 I
Serious21$625$625Nov 9, 2004--
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 I
Serious13$0$0Nov 9, 2004--
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious12$625$625Nov 9, 2004--
01004A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 I03
Serious15$625$625Nov 9, 2004--
01004B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 I04
Serious15$0$0Nov 9, 2004--
01005A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious15$625$625Nov 9, 2004--
01005B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Serious13$0$0Nov 9, 2004--
01006A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious15$375$375Dec 7, 2004--
01006B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious15$0$0Dec 7, 2004--
01006C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious15$0$0Dec 7, 2004--
020011926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 I
Repeat15$1,000$1,000Nov 9, 2004--
03001ARM0307
OSHA citation code: ARM0307 E01
Other11$1,000$1,000Mar 5, 2005--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements4 citations · $2,625
1910.1200Hazard Communication3 citations · $375
1926.501Fall Protection - Duty to Have Fall Protection3 citations · $9,625

Industry comparison

Violations per inspection
This employer6.3
Industry average2.1
Penalties per inspection
This employer$5,750
Industry average$2,541

Specialty Trade Contractors, 558,619 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in FAIRFAX, VA

All employers in FAIRFAX →