AMERICAN INDUSTRIAL HEAT TRANSFER, INC.
3905 ROUTE 173, Zion, IL 60099 · NAICS 332410 Power Boiler and Heat Exchanger Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 24, 2009#313724759Aug 24, 2009Follow-Up (F) · Partial scope, Safety#313724759$7,2005 viol.5 violations$7,200 in penalties
Inspection #313724759
Dates
- Opened
- Aug 24, 2009
- Closing Conference Date
- Aug 28, 2009
- Closed
- Jun 5, 2014
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 80
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 3 serious, 2 other-than-serious
- Initial Penalties
- $7,200
- Penalties on Record
- $7,200
- Site Address
- 3905 Route 173, Zion, IL 60099
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 2 | $1,500 | $1,500 | Oct 19, 2009 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $3,000 | $3,000 | Sep 4, 2009 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 1 | 2 | $1,500 | $1,500 | Sep 4, 2009 | - | - |
| 02001 | 1903.19 Abatement Verification OSHA citation code: 19030019 D01 | Other | 3 | - | $600 | $600 | Sep 18, 2009 | - | - |
| 02002 | 1904.29 Forms OSHA citation code: 19040029 B03 | Other | 1 | 1 | $600 | $600 | Sep 18, 2009 | - | - |
Aug 24, 2009#313658692Aug 24, 2009Follow-Up (F) · Partial scope, Health#313658692$1,2004 viol.4 violations$1,200 in penalties
Inspection #313658692
Dates
- Opened
- Aug 24, 2009
- Closing Conference Date
- Sep 3, 2009
- Contested
- Sep 29, 2009
- Final Order
- Dec 5, 2011
- Closed
- Feb 10, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 22
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 2 serious, 2 other-than-serious
- Initial Penalties
- $3,600
- Penalties on Record
- $1,200
- Site Address
- 3905 Route 173, Zion, IL 60099
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 2 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 2 | 0 | mg/m³ |
| Cadmium | 2 | 0 - 0.0012713 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 2 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 2 | 0 | mg/m³ |
| Copper Fume (as Cu) | 2 | 0 | mg/m³ |
| Iron Oxide Fume | 2 | 0.3278109 - 0.6944755 | mg/m³ |
| Lead, Inorganic (as Pb) | 2 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 2 | 0.0289112 - 0.0619102 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 2 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 2 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 2 | 0 | mg/m³ |
| Zinc Oxide Fume | 2 | 0 | mg/m³ |
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 1 | $1,200 | $500 | Sep 21, 2009 | Sep 29, 2009 | Dec 5, 2011 |
| 01002 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 1 | $1,200 | $500 | Sep 21, 2009 | Sep 29, 2009 | Dec 5, 2011 |
| 02001 | 1903.19 Abatement Verification OSHA citation code: 19030019 D01 | Other | 1 | 2 | $600 | $100 | Sep 28, 2009 | Sep 29, 2009 | Dec 5, 2011 |
| 02002 | 1904.40 Providing records to government representatives OSHA citation code: 19040040 A | Other | 1 | 80 | $600 | $100 | Sep 21, 2009 | Sep 29, 2009 | Dec 5, 2011 |
Jan 22, 2008#311718852Jan 22, 2008Complaint (B) · Partial scope, Health#311718852$1,8004 viol.4 violations$1,800 in penalties
Inspection #311718852
Dates
- Opened
- Jan 22, 2008
- Closing Conference Date
- Mar 20, 2008
- Contested
- Apr 1, 2008
- Final Order
- Jul 29, 2009
- Closed
- Feb 23, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 61
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $3,750
- Penalties on Record
- $1,800
- Site Address
- 3905 Route 173, Zion, IL 60099
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 7 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 7 | 0 | mg/m³ |
| Cadmium | 7 | 0 - 0.0010536 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 7 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 7 | 0 | mg/m³ |
| Copper Fume (as Cu) | 7 | 0 - 0.0854801 | mg/m³ |
| Iron Oxide Fume | 7 | 0 - 7.9871583 | mg/m³ |
| Lead, Inorganic (as Pb) | 7 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 7 | 0 - 0.6412444 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 7 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 7 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 7 | 0 | mg/m³ |
| Zinc Oxide Fume | 7 | 0 - 0.2560306 | mg/m³ |
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Serious | 4 | 4 | $2,500 | $900 | Apr 16, 2008 | Apr 1, 2008 | Jul 29, 2009 |
| 01002A | 1910.1000 Air Contaminants OSHA citation code: 19101000 D02 I | Serious | 1 | 1 | $1,250 | $900 | Jun 30, 2008 | Apr 1, 2008 | Jul 29, 2009 |
| 01002B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 1 | $0 | $0 | Jun 30, 2008 | Apr 1, 2008 | Jul 29, 2009 |
| 02001 | 1904.29 Forms OSHA citation code: 19040029 A | Other | 1 | - | $0 | $0 | Apr 9, 2008 | Apr 1, 2008 | Jul 29, 2009 |
Failure to Abate Penalties1 citation, $300 in FTA penalties on record
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|---|---|---|---|---|
| 02001 | #313658692 | Sep 9, 2009 | $300 | Sep 29, 2009 | Dec 5, 2011 |
Jan 22, 2008#311718845Jan 22, 2008Complaint (B) · Partial scope, Safety#311718845$1,2003 viol.3 violations$1,200 in penalties
Inspection #311718845
Dates
- Opened
- Jan 22, 2008
- Closing Conference Date
- Mar 24, 2008
- Contested
- Apr 1, 2008
- Final Order
- Jul 29, 2009
- Closed
- Jan 4, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 58
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 2 serious, 1 other-than-serious
- Initial Penalties
- $2,500
- Penalties on Record
- $1,200
- Site Address
- 3905 Route 173, Zion, IL 60099
- Industry
- 332410 Power Boiler and Heat Exchanger Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 OSHA citation code: 19100023 C01 | Serious | 1 | 1 | $1,250 | $600 | Apr 10, 2008 | Apr 1, 2008 | Jul 29, 2009 |
| 01002 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 1 | $1,250 | $600 | May 8, 2008 | Apr 1, 2008 | Jul 29, 2009 |
| 02001 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L04 III | Other | 1 | 4 | $0 | $0 | Apr 24, 2008 | Apr 1, 2008 | Jul 29, 2009 |
Failure to Abate Penalties2 citations, $21,000 in FTA penalties on record
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|---|---|---|---|---|
| 01002 | #313724759 | Aug 31, 2009 | $15,000 | - | - |
| 02001 | #313724759 | Aug 31, 2009 | $6,000 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 2008 to 2009. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Fabricated Metal Product Manufacturing, 45,931 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: power boiler and heat exchanger manufacturing reported 3.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 16.5%; NAICS 33241 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source