Inspections
4
Jul 2001 to Mar 2003 · 1 safety, 3 health
Violations
42
across 4 inspections
Penalties on record
$3,850
latest amounts in DOL records
By classification
Serious 21Willful 0Repeat 3Other 18

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 27, 2003Complaint (B) · Partial scope, Health#306248139$1,2505 viol.

Inspection #306248139

Dates

Opened
Mar 27, 2003
Closing Conference Date
May 12, 2003
Closed
Jul 25, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 repeat
Initial Penalties
$4,925
Penalties on Record
$1,250
Site Address
11317 Frederick Avenue, Beltsville, MD 20705
Industry
334290 Other Communications Equipment Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC20.179 - 0.4941mg/m³
Particulates not otherwise regulated (Respirable Fraction)20.179 - 0.4941mg/m³
Sample WeightQC20.021 - 0.042mg

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat11$2,400$500Jun 1, 2003--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Repeat12$600$100May 30, 2003--
030011910.133
Eye and Face Protection
OSHA citation code: 19100133 A03
Serious12$1,100$400Jun 1, 2003--
04001A1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 II
Serious11$825$250May 30, 2003--
04001B1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious11$0$0May 30, 2003--
Oct 9, 2002Follow-Up (F) · Partial scope, Health#305573966$2502 viol.

Inspection #305573966

Dates

Opened
Oct 9, 2002
Closing Conference Date
Oct 28, 2002
Closed
Apr 1, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30

Violations and Penalties

Total Violations
2
Violation Types
1 repeat, 1 other-than-serious
Initial Penalties
$1,200
Penalties on Record
$250
Site Address
11317 Frederick Avenue, Beltsville, MD 20705
Industry
334290 Other Communications Equipment Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Repeat12$1,200$250Nov 23, 2002--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 II
Other12$0$0Dec 21, 2002--
Aug 3, 2001Referral (C) · Partial scope, Safety#304470362$1,3003 viol.

Inspection #304470362

Dates

Opened
Aug 3, 2001
Closing Conference Date
Aug 15, 2001
Closed
Mar 21, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$3,250
Penalties on Record
$1,300
Site Address
11317 Frederick Avenue, Beltsville, MD 20705
Industry
334290 Other Communications Equipment Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious93$1,500$600Sep 23, 2001--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious13$1,250$500Sep 23, 2001--
020011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious13$500$200Sep 21, 2001--
Jul 3, 2001Complaint (B) · Partial scope, Health#304530330$1,05032 viol.

Inspection #304530330

Dates

Opened
Jul 3, 2001
Closing Conference Date
Aug 3, 2001
Closed
Apr 1, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30
Related Activity
1 complaint

Violations and Penalties

Total Violations
32
Violation Types
15 serious, 17 other-than-serious
Initial Penalties
$3,375
Penalties on Record
$1,050
Site Address
11317 Frederick Avenue, Beltsville, MD 20705
Industry
334290 Other Communications Equipment Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 32 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B01
Serious11$675$300Jun 10, 2002--
01001B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious11$0$0Jun 10, 2002--
01001C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious11$0$0Jun 10, 2002--
01001D1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Serious11$0$0Sep 19, 2001--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Serious130$900$200Oct 17, 2001--
03001A1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 III
Serious31$1,125$300Sep 19, 2001--
03001B1910.307
Hazardous (classified) locations
OSHA citation code: 19100307 B01
Serious21$0$0Oct 2, 2001--
03001C1910.307
Hazardous (classified) locations
OSHA citation code: 19100307 B02 II
Serious11$0$0Sep 19, 2001--
04001A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious115$675$250Oct 17, 2001--
04001B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious115$0$0Sep 19, 2001--
04001C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious130$0$0Oct 17, 2001--
04001D1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious130$0$0Sep 19, 2001--

Showing the 12 violations listed first by citation identifier. This inspection has 32 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties3 citations, $400 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 3 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001C#305573966Nov 18, 2002$100--
03001B#305573966Nov 18, 2002$100--

Showing the 2 FTA rows present in the first 12 citations on this inspection. OSHA's record shows 3 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection12 citations · $350
1910.1200Hazard Communication5 citations · $250
1910.107Spray Finishing Using Flammable and Combustible Materials4 citations · $300

Chemical exposure sampling

Samples
6
Substances
3
Inspections
1

Industry comparison

Violations per inspection
This employer10.5
Industry average2.7
Penalties per inspection
This employer$963
Industry average$1,737

Computer and Electronic Product Manufacturing, 5,426 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: other communications equipment manufacturing reported 1.6 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 24.1%; NAICS 33429 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source