Skip to content
SafetyRecord logoSafetyRecord
APPLIED PLASTIC COATINGS, INC.
$2,400
penalties
15
viol.
1
insp.

APPLIED PLASTIC COATINGS, INC.

11771 WEST 49TH AVENUE, WHEAT RIDGE, CO 80033

Inspections
1
Jun 2000 to Jun 2000 · 0 safety, 1 health
Violations
15
across 1 inspection
Penalties on record
$2,400
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 6

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 21, 2000Complaint (B) · Partial scope, Health#303617542$2,40015 viol.

Inspection #303617542

Dates

Opened
Jun 21, 2000
Closing Conference Date
Nov 2, 2000
Closed
May 15, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15
Related Activity
1 complaint

Violations and Penalties

Total Violations
15
Violation Types
9 serious, 6 other-than-serious
Initial Penalties
$4,200
Penalties on Record
$2,400
Site Address
11771 West 49th Avenue, Wheat Ridge, CO 80033
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Arsenic, Inorganic32P / 1A0 - 0.047
Beryllium and Beryllium Compounds (as Be)40mg/m³
Cadmium32P / 1A0 - 0.0039
Chromium, Metal and Insoluble Salts40 - 0.2027782mg/m³
Cobalt, Metal, Dust and Fume (as Co)40 - 0.0085805mg/m³
Copper Fume (as Cu)40 - 0.263409mg/m³
Gravimetric DeterminationQC60 - 28.9474mg/m³
Iron Oxide Fume40 - 128.6839294mg/m³
Lead, Inorganic (as Pb)65P / 1A0 - 0.12mg/m³
Manganese Fume (as Mn)40 - 0.9032722mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40 - 0.0525498mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40 - 0.1208228mg/m³
Sample WeightQC60 - 3.96mg
Silica, Crystalline Quartz (Respirable Fraction)40 - 17%
Vanadium fume (as V2O5)40 - 0.0139103mg/m³
Zinc Oxide Fume40 - 1.6009169mg/m³

Violations

Violation list (15 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious310$1,500$1,250Feb 15, 2001--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 D01 III
Serious110$0$0Dec 27, 2000--
01001C1910.1000
Air Contaminants
OSHA citation code: 19101000 A
Serious12$0$0Dec 27, 2000--
01001D1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious21$0$0Dec 27, 2000--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$600$0Dec 27, 2000--
01003A1910.1018
Inorganic Arsenic
OSHA citation code: 19101018 E02
Serious13$1,500$850Dec 27, 2000--
01003B1910.1018
Inorganic Arsenic
OSHA citation code: 19101018 N01 IA
Serious13$0$0Dec 27, 2000--
01003C1910.1018
Inorganic Arsenic
OSHA citation code: 19101018 O01 I
Serious23$0$0Dec 27, 2000--
010041910.1025
Lead
OSHA citation code: 19101025 L01 I
Serious13$600$300Dec 27, 2000--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other110$0$0Dec 27, 2000--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other18$0$0Dec 27, 2000--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other27$0$0Dec 5, 2000--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other16$0$0Dec 5, 2000--
020051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other24$0$0Dec 5, 2000--
020061910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Other11$0$0Dec 5, 2000--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1018Inorganic Arsenic3 citations · $850
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $0
1910.134Respiratory Protection2 citations · $1,250

Chemical exposure sampling

Samples
72
Substances
17
Inspections
1

Other inspected employers in WHEAT RIDGE, CO

All employers in WHEAT RIDGE →