Skip to content
SafetyRecord logoSafetyRecord
ARMSTRONG ENGINEERING ASSOCIATES, INC.
$1,715
penalties
6
viol.
1
insp.

ARMSTRONG ENGINEERING ASSOCIATES, INC.

1845 W. STRASBURG RD., COATESVILLE, PA 19320NAICS 332420 Metal Tank (Heavy Gauge) Manufacturing

Inspections
1
May 2008 to May 2008 · 0 safety, 1 health
Violations
6
across 1 inspection
Penalties on record
$1,715
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 23, 2008Complaint (B) · Partial scope, Health#310721287$1,7156 viol.

Inspection #310721287

Dates

Opened
May 23, 2008
Closing Conference Date
May 23, 2008
Closed
Aug 1, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$2,450
Penalties on Record
$1,715
Site Address
1845 W. Strasburg Rd., Coatesville, PA 19320
Industry
332420 Metal Tank (Heavy Gauge) Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium20mg/m³
Chromic Acid and Chromates (as CrO3)10mg/m³
Chromium, Metal and Insoluble Salts20 - 0.011735mg/m³
Chromium (VI) - TWA10mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20 - 0.0038002mg/m³
Iron Oxide Fume20.7511976 - 1.0209426mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20.0217694 - 0.1234365mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20 - 0.0331211mg/m³
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20 - 0.0367893mg/m³

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious53$525$325Jul 25, 2008--
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious23$525$325Aug 24, 2008--
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious33$0$0Aug 24, 2008--
01002C1910.134
Respiratory Protection
OSHA citation code: 19100134 H01
Serious23$0$0Jul 25, 2008--
010031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Serious43$525$325Aug 4, 2008--
010041910.1026
Chromium (VI)
OSHA citation code: 19101026 D02 I
Serious13$875$740Jul 25, 2008--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection3 citations · $325
1910.101Compressed Gases (General Requirements)1 citation · $325
1910.157Portable Fire Extinguishers1 citation · $325

Chemical exposure sampling

Samples
28
Substances
15
Inspections
1

Industry comparison

Violations per inspection
This employer6.0
Industry average3.3
Penalties per inspection
This employer$1,715
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,875 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: metal tank (heavy gauge) manufacturing reported 3.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.7%; NAICS 33242 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in COATESVILLE, PA

All employers in COATESVILLE →