Inspection records

Dec 16, 2009Planned (H) · Partial scope, Safety#314101171$8442 viol.

Inspection #314101171

Dates

Opened
Dec 16, 2009
Closing Conference Date
Dec 24, 2009
Closed
Feb 5, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
19

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$1,125
Penalties on Record
$844
Site Address
15463 Old Mcgregor Boulevard, Fort Myers, FL 33908
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious15$1,125$844Feb 2, 2010--
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H02 II
Other15$0$0Jan 21, 2010--
Aug 10, 2004Planned (H) · Complete scope, Safety#307994368$6,0007 viol.

Inspection #307994368

Dates

Opened
Aug 10, 2004
Closing Conference Date
Aug 10, 2004
Closed
Nov 15, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
7
Violation Types
6 serious, 1 other-than-serious
Initial Penalties
$3,450
Penalties on Record
$6,000
Site Address
4501 Colonial Blvd., Fort Myers, FL 33901
Industry
238110 Poured Concrete Foundation and Structure Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other11$450$0Sep 27, 2004--
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B15
Serious44$1,500$1,500Sep 27, 2004--
010081926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Serious11$1,500$1,500Sep 27, 2004--
01009A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D09
Serious55$0$1,500Sep 27, 2004--
01009B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D21
Serious15$0$0Sep 27, 2004--
01010A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D15
Serious55$0$1,500Sep 27, 2004--
01010B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D15 III
Serious44$0$0Sep 27, 2004--
May 12, 2004Planned (H) · Complete scope, Safety#307402842$3,8009 viol.

Inspection #307402842

Dates

Opened
May 12, 2004
Closing Conference Date
May 12, 2004
Closed
Oct 29, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
9
Violation Types
8 serious, 1 other-than-serious
Initial Penalties
$5,775
Penalties on Record
$3,800
Site Address
6320 Techster Blvd., Building C, Fort Myers, FL 33908
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.51
Sanitation (Construction)
OSHA citation code: 19260051 A04
Serious112$525$345Jul 16, 2004--
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious112$700$460Jun 29, 2004--
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 II
Serious11$0$0Jul 16, 2004--
01003A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F03
Serious112$1,225$806Jul 16, 2004--
01003B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious112$0$0Jul 16, 2004--
010041926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F14
Serious112$1,225$806Jun 29, 2004--
010051926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 C02
Serious112$1,225$806Jul 16, 2004--
010061926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Serious112$875$577Jul 16, 2004--
020011926.103
Respiratory Protection (Construction)
OSHA citation code: 19260103 D01 III
Other112$0$0Jun 29, 2004--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements7 citations · $2,916
1926.502Fall Protection Systems Criteria and Practices4 citations · $3,000
1926.404Electrical - Wiring Design and Protection (Construction)1 citation · $0

Industry comparison

Violations per inspection
This employer6.0
Industry average2.1
Penalties per inspection
This employer$3,548
Industry average$2,530

Specialty Trade Contractors, 551,622 employers with OSHA inspections. Arithmetic from DOL records.