Skip to content
SafetyRecord logoSafetyRecord
BARRON & BROTHERS, INC.
$3,747
penalties
16
viol.
1
insp.

BARRON & BROTHERS, INC.

2305 WHITE SULPHUR RD., GAINESVILLE, GA 30501

Inspections
1
Jan 1997 to Jan 1997 · 0 safety, 1 health
Violations
16
across 1 inspection
Penalties on record
$3,747
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 16, 1997Planned (H) · Complete scope, Health#109300574$3,74716 viol.

Inspection #109300574

Dates

Opened
Jan 16, 1997
Closing Conference Date
Jan 16, 1997
Closed
Mar 12, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
16
Violation Types
14 serious, 2 other-than-serious
Initial Penalties
$4,996
Penalties on Record
$3,747
Site Address
2305 White Sulphur Rd., Gainesville, GA 30501
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)70 - 0.1152mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Chromium, Metal and Insoluble Salts70.0014 - 0.0033mg/m³
Cobalt, Metal, Dust and Fume (as Co)70mg/m³
Copper Fume (as Cu)70 - 0.0672mg/m³
Iron Oxide Fume70.92 - 5.3593mg/m³
Lead, Inorganic (as Pb)70 - 0.0179mg/m³
Manganese Fume (as Mn)70.0653 - 0.5403mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)70mg/m³
Nickel, Metal and Insoluble compounds (as Ni)70 - 0.0011mg/m³
Vanadium fume (as V2O5)70mg/m³
Zinc Oxide Fume70.0029 - 0.0492mg/m³

Violations

Violation list (16 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB2
Serious110$446$446Jan 16, 1997--
01002A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious11$700$700Feb 7, 1997--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 F04
Serious11$0$0Feb 14, 1997--
01002C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Serious11$0$0Feb 14, 1997--
01003A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious11$525$525Feb 24, 1997--
01003B1910.138
Hand Protection
OSHA citation code: 19100138 A
Serious11$0$0Feb 14, 1997--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious22$875$875Feb 24, 1997--
01005A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious12$700$700Feb 7, 1997--
01005B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious12$0$0Feb 7, 1997--
01005C1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$0$0Feb 24, 1997--
010061910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 C02 IC
Serious11$525$276Feb 24, 1997--
01007A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious110$1,225$225Mar 3, 1997--
01007B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious110$0$0Mar 3, 1997--
01007C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious110$0$0Mar 3, 1997--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 B06
Other11$0$0Feb 24, 1997--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 B07
Other11$0$0Feb 24, 1997--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication3 citations · $225
1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $700
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $875

Chemical exposure sampling

Samples
83
Substances
12
Inspections
1

Other inspected employers in GAINESVILLE, GA

All employers in GAINESVILLE →