Skip to content
SafetyRecord logoSafetyRecord
BECTON DICKINSON & CORP
$36,532
penalties
9
viol.
4
insp.

BECTON DICKINSON & CORP

HIGHWAY 30, Columbus, NE 68601

Inspections
4
May 1976 to May 2025 · 3 safety, 1 health
Violations
9
across 4 inspections
Penalties on record
$36,532
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 20, 2025Complaint (B) · Partial scope, Safety#348257197$28,5327 viol.

Inspection #348257197

Dates

Opened
May 20, 2025
Closing Conference Date
Aug 13, 2025
Final Order
Dec 1, 2025
Closed
Feb 6, 2026

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1,244
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
7 serious
Initial Penalties
$40,760
Penalties on Record
$28,532
Site Address
1852 10th Avenue, Columbus, NE 68601
Industry
339112 Surgical and Medical Instrument Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious12$12,059$8,441Jan 15, 2026-Dec 1, 2025
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I A
Serious12$0$0Jan 15, 2026-Dec 1, 2025
01002A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 X
Serious11$6,150$4,305-Dec 1, 2025
01002B1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Serious11$0$0-Dec 1, 2025
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious11$6,150$4,305-Dec 1, 2025
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 III D
Serious12$6,150$4,305-Dec 1, 2025
010051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious12$10,251$7,176-Dec 1, 2025
Apr 9, 2015Referral (C) · Partial scope, Safety#340528959$7,0001 viol.

Inspection #340528959

Dates

Opened
Apr 9, 2015
Closing Conference Date
Apr 10, 2015
Final Order
May 19, 2015
Closed
May 29, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
996
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$7,000
Penalties on Record
$7,000
Site Address
1852 10th Avenue, Columbus, NE 68601
Industry
339112 Surgical and Medical Instrument Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious105$7,000$7,000May 26, 2015-May 19, 2015
Jan 29, 2015Referral (C) · Partial scope, Health#340220839$1,0001 viol.

Inspection #340220839

Dates

Opened
Jan 29, 2015
Closing Conference Date
May 27, 2015
Final Order
Jul 10, 2015
Closed
Jul 21, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1,000
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$1,000
Site Address
1852 10th Avenue, Columbus, NE 68601
Industry
339112 Surgical and Medical Instrument Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.29
Forms
OSHA citation code: 19040029 B03
Other11,000$1,000$1,000Jul 30, 2015-Jul 10, 2015
May 4, 1976Complaint (B) · Partial scope, Safety#17282823$00 viol.

Inspection #17282823

Dates

Opened
May 4, 1976
Closing Conference Date
May 5, 1976
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
695

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Highway 30, Columbus, NE 68601
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment4 citations · $20,091
1910.147Control of Hazardous Energy (Lockout/Tagout)2 citations · $8,441
1904.29Forms1 citation · $1,000

Industry comparison

BLS 2024 survey: surgical and medical instrument manufacturing reported 1.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.3%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Columbus, NE

All employers in Columbus →