Skip to content
SafetyRecord logoSafetyRecord
BEHR DAYTON THERMAL PRODUCTS LLC
$86,875
penalties
38
viol.
6
insp.

BEHR DAYTON THERMAL PRODUCTS LLC

1600 WEBSTER ST., DAYTON, OH 45404NAICS 336391

Inspections
6
Sep 2004 to Jun 2010 · 3 safety, 3 health
Violations
38
across 6 inspections
Penalties on record
$86,875
latest amounts in DOL records
By classification
Serious 31Willful 0Repeat 3Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 9, 2010Complaint (B) · Partial scope, Safety#314584160$55,0009 viol.

Inspection #314584160

Dates

Opened
Jun 9, 2010
Closing Conference Date
Jul 13, 2010
Contested
Sep 27, 2010
Final Order
Dec 31, 2010
Closed
Jan 27, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1,150
Related Activity
1 complaint

Violations and Penalties

Total Violations
9
Violation Types
6 serious, 3 repeat
Initial Penalties
$77,500
Penalties on Record
$55,000
Site Address
1600 Webster St., Dayton, OH 45404
Industry
336391

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (8 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious22$2,500$1,500Sep 27, 2010Sep 27, 2010Dec 31, 2010
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious896$5,000$3,000Sep 27, 2010Sep 27, 2010Dec 31, 2010
010031910.332
Electrical Safety-Related Work Practices - Training
OSHA citation code: 19100332 B01
Serious42$5,000$2,000Sep 27, 2010Sep 27, 2010Dec 31, 2010
010041910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 A02
Serious62$5,000$1,000Sep 27, 2010Sep 27, 2010Dec 31, 2010
010051910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02
Serious11$5,000$1,000Sep 27, 2010Sep 27, 2010Dec 31, 2010
010061910.335
Electrical - Safeguards
OSHA citation code: 19100335 A01 I
Serious152$5,000$1,000Sep 27, 2010Sep 27, 2010Dec 31, 2010
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Repeat888$25,000$22,500Sep 27, 2010Sep 27, 2010Dec 31, 2010
02002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D03
Repeat388$25,000$23,000Sep 27, 2010Sep 27, 2010Dec 31, 2010

Showing the 8 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 22, 2008Planned (H) · Partial scope, Safety#311870042$10,0004 viol.

Inspection #311870042

Dates

Opened
Feb 22, 2008
Closing Conference Date
Feb 28, 2008
Closed
Apr 29, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1,646

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$20,000
Penalties on Record
$10,000
Site Address
1600 Webster St., Dayton, OH 45404
Industry
336391

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious1-$5,000$2,500Apr 3, 2008--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious1-$5,000$2,500Apr 3, 2008--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious3-$5,000$2,500Apr 3, 2008--
010041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious2-$5,000$2,500Apr 3, 2008--
May 4, 2005Complaint (B) · Partial scope, Health#308766435$00 viol.

Inspection #308766435

Dates

Opened
May 4, 2005
Closing Conference Date
May 4, 2005
Closed
Jun 22, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1,700
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1600 Webster St., Dayton, OH 45404
Industry
336391

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Coal Tar Pitch Volatiles (benzene soluble fraction)50 - 78mg/m³
Jan 19, 2005Complaint (B) · Partial scope, Health#308510130$1,8752 viol.

Inspection #308510130

Dates

Opened
Jan 19, 2005
Closing Conference Date
Jan 20, 2005
Closed
Mar 3, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1,850
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$1,875
Penalties on Record
$1,875
Site Address
1600 Webster St., Dayton, OH 45404
Industry
336391

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Fluorides (as F)10X
Gravimetric DeterminationQC40.1637 - 28.2395mg/m³
Hydrogen Fluoride (as F)10ppm
Particulates not otherwise regulated (Respirable Fraction)40.1637 - 28.2395mg/m³
Sample WeightQC40.085 - 1.75mg

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 H03 II
Serious14$1,875$1,875Feb 23, 2005--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 G01 IA
Other11$0$0Jan 27, 2005--
Sep 16, 2004Complaint (B) · Partial scope, Safety#308043645$10,00011 viol.

Inspection #308043645

Dates

Opened
Sep 16, 2004
Closing Conference Date
Oct 5, 2004
Closed
Feb 28, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1,850
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
9 serious, 2 other-than-serious
Initial Penalties
$32,400
Penalties on Record
$10,000
Site Address
1600 Webster St., Dayton, OH 45404
Industry
336391

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (8 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious23$1,800$1,500Nov 10, 2004--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C02 III
Serious12$4,500$1,500Oct 27, 2004--
01003A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious33$4,500$1,000Dec 10, 2004--
01003B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious16$0$0Dec 10, 2004--
010041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IIIA
Serious19$4,500$1,000Dec 10, 2004--
010051910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D03
Serious33$4,500$1,000Nov 10, 2004--
010061910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious35$4,500$1,000Dec 10, 2004--
010071910.176
Handling Materials - General
OSHA citation code: 19100176 A
Other34$2,250$500Dec 10, 2004--

Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 16, 2004Complaint (B) · Partial scope, Health#308043637$10,00012 viol.

Inspection #308043637

Dates

Opened
Sep 16, 2004
Closing Conference Date
Oct 5, 2004
Closed
Feb 14, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1,850
Related Activity
1 complaint

Violations and Penalties

Total Violations
12
Violation Types
11 serious, 1 other-than-serious
Initial Penalties
$18,750
Penalties on Record
$10,000
Site Address
1600 Webster St., Dayton, OH 45404
Industry
336391

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (8 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious12$1,875$1,500Dec 8, 2004--
01001B1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Serious11$0$0Dec 8, 2004--
010021910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious22$1,875$1,500Dec 8, 2004--
010031910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D09
Serious12$1,875$2,000Jan 31, 2005--
01004A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 E01
Serious12$1,875$1,500Dec 8, 2004--
01004B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 E06
Serious12$0$0Dec 8, 2004--
010051910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 K01 III
Serious12$1,875$500Jan 31, 2005--
010061910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 K01 V
Serious12$1,875$500Jan 31, 2005--

Showing the 8 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)13 citations · $61,500
1910.146Permit-Required Confined Spaces6 citations · $5,000
1910.1200Hazard Communication3 citations · $3,375

Chemical exposure sampling

Samples
19
Substances
6
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer6.3
Industry average2.9
Penalties per inspection
This employer$14,479
Industry average$2,680

Transportation Equipment Manufacturing, 17,010 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in DAYTON, OH