Skip to content
SafetyRecord logoSafetyRecord
BEVERIDGE CONSTRUCTION
$27,475
penalties
46
viol.
6
insp.

BEVERIDGE CONSTRUCTION

4023-27 BREAKWOOD, HOUSTON, TX 77025NAICS 238130 Framing Contractors

Inspections
6
Aug 2001 to Jun 2006 · 3 safety, 3 health
Violations
46
across 6 inspections
Penalties on record
$27,475
latest amounts in DOL records
By classification
Serious 36Willful 0Repeat 5Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 24, 2006Planned (H) · Partial scope, Safety#308321926$5,0008 viol.

Inspection #308321926

Dates

Opened
Jun 24, 2006
Closing Conference Date
Jun 24, 2006
Closed
Apr 25, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
8
Violation Types
8 serious
Initial Penalties
$9,000
Penalties on Record
$5,000
Site Address
4023-27 Breakwood, Houston, TX 77025
Industry
236210 Industrial Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious35$1,000$500Oct 12, 2006--
01001B1926.102
Eye and Face Protection (Construction)
OSHA citation code: 19260102 A01
Serious35$0$0Oct 12, 2006--
01002A1926.150
Fire Protection (Construction)
OSHA citation code: 19260150 A02
Serious15$1,000$500Oct 12, 2006--
01002B1926.151
Fire Prevention
OSHA citation code: 19260151 C06
Serious15$0$0Oct 12, 2006--
010031926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Serious25$1,000$1,000Oct 12, 2006--
010041926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious15$1,000$1,000Oct 10, 2006--
010051926.1053
Ladders (Construction)
OSHA citation code: 19261053 B13
Serious25$1,000$1,000Oct 10, 2006--
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious45$4,000$1,000Oct 10, 2006--
Aug 31, 2005Planned (H) · Partial scope, Health#308316991$6,70011 viol.

Inspection #308316991

Dates

Opened
Aug 31, 2005
Closing Conference Date
Aug 31, 2005
Closed
May 2, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
11
Violation Types
5 serious, 3 repeat, 3 other-than-serious
Initial Penalties
$16,575
Penalties on Record
$6,700
Site Address
4023-27 Breakwood, Houston, TX 77025
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 I
Other16$675$300Nov 14, 2005--
01002A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 A02
Other16$1,125$600Nov 14, 2005--
01002B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious16$0$0Nov 14, 2005--
01002C1926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious26$0$0Nov 14, 2005--
01003A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious66$3,000$1,000Nov 14, 2005--
01003B1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious66$0$0Dec 13, 2005--
01004A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Other26$1,575$800Nov 14, 2005--
01004B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B06
Serious36$0$0Nov 14, 2005--

Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 30, 2005Planned (H) · Partial scope, Health#308317015$5,50011 viol.

Inspection #308317015

Dates

Opened
Aug 30, 2005
Closing Conference Date
Aug 30, 2005
Closed
May 2, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
11
Violation Types
7 serious, 2 repeat, 2 other-than-serious
Initial Penalties
$13,575
Penalties on Record
$5,500
Site Address
4023-27 Breakwood, Houston, TX 77025
Industry
238350 Finish Carpentry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 A02
Other14$1,125$500Nov 14, 2005--
01001B1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious14$0$0Nov 14, 2005--
01001C1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious14$0$0Nov 14, 2005--
01001D1926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious24$0$0Nov 14, 2005--
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01
Serious14$1,575$800Nov 14, 2005--
01002B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H02 II
Serious14$0$0Nov 14, 2005--
01002C1926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 C02
Serious14$0$0Nov 14, 2005--
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious14$1,575$700Nov 14, 2005--

Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 21, 2003Programmed Related (I) · Complete scope, Safety#306564816$2,1006 viol.

Inspection #306564816

Dates

Opened
Aug 21, 2003
Closing Conference Date
Aug 22, 2003
Closed
Dec 24, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$4,200
Penalties on Record
$2,100
Site Address
12102 Veterans Memorial, Houston, TX 77014
Industry
238170 Siding Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious44$600$300Nov 6, 2003--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A06
Serious24$1,000$500Nov 3, 2003--
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious33$800$400Nov 3, 2003--
010041926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H01
Serious14$800$400Nov 3, 2003--
01005A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious23$1,000$500Nov 3, 2003--
01005B1926.1060
Stairways and Ladders - Training (Construction)
OSHA citation code: 19261060 A
Serious23$0$0Nov 3, 2003--
Dec 10, 2001Programmed Related (I) · Partial scope, Health#304569452$8,17510 viol.

Inspection #304569452

Dates

Opened
Dec 10, 2001
Closing Conference Date
Mar 7, 2002
Contested
Jun 7, 2002
Final Order
Sep 3, 2002
Closed
Mar 7, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
10
Violation Types
10 serious
Initial Penalties
$8,175
Penalties on Record
$8,175
Site Address
4023-27 Breakwood, Houston, TX 77025
Industry
238130 Framing Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (8 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious14$1,500$1,500Apr 10, 2002Jun 7, 2002Sep 3, 2002
010021926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Serious14$1,500$1,500Apr 10, 2002Jun 7, 2002Sep 3, 2002
010031926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious24$525$525Mar 13, 2002Jun 7, 2002Sep 3, 2002
010041926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 IV
Serious34$225$225Mar 13, 2002Jun 7, 2002Sep 3, 2002
010051926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 I02 I
Serious14$375$375Mar 13, 2002Jun 7, 2002Sep 3, 2002
010061926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Serious14$375$375Mar 13, 2002Jun 7, 2002Sep 3, 2002
010071926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E02
Serious14$375$375Mar 13, 2002Jun 7, 2002Sep 3, 2002
010081926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious34$1,500$1,500Mar 13, 2002Jun 7, 2002Sep 3, 2002

Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 23, 2001Planned (H) · No Inspection scope, Safety#304505068$00 viol.

Inspection #304505068

Dates

Opened
Aug 23, 2001
Closing Conference Date
Not recorded
Closed
Nov 30, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
12102 Veterans Memorial, Houston, TX 77014
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.1053Ladders (Construction)7 citations · $5,300
1926.451Scaffolding - General Requirements6 citations · $3,600
1926.100Head Protection (Construction)5 citations · $5,325

Industry comparison

Violations per inspection
This employer7.7
Industry average2.1
Penalties per inspection
This employer$4,579
Industry average$2,528

Specialty Trade Contractors, 551,545 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in HOUSTON, TX

All employers in HOUSTON →