Skip to content
SafetyRecord logoSafetyRecord
BLACKSTONE CONTRACTORS LLC
$13,400
penalties
11
viol.
6
insp.

BLACKSTONE CONTRACTORS LLC

115 KINGSTON AVE, BROOKLYN, NY 11213NAICS 238130 Framing Contractors

Inspections
6
Aug 2017 to Aug 2018 · 6 safety, 0 health
Violations
11
across 6 inspections
Penalties on record
$13,400
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 31, 2018Follow-Up (F) · Partial scope, Safety#343433017$00 viol.

Inspection #343433017

Dates

Opened
Aug 31, 2018
Closing Conference Date
Aug 31, 2018
Closed
Sep 19, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1363 Union Street, Brooklyn, NY 11213
Industry
238130 Framing Contractors

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 31, 2018Follow-Up (F) · Partial scope, Safety#343432969$00 viol.

Inspection #343432969

Dates

Opened
Aug 31, 2018
Closing Conference Date
Aug 31, 2018
Closed
Sep 19, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
654 Easten Parkway, Brooklyn, NY 11213
Industry
238130 Framing Contractors

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 10, 2018Planned (H) · Partial scope, Safety#343155800$00 viol.

Inspection #343155800

Dates

Opened
May 10, 2018
Closing Conference Date
May 10, 2018
Closed
Nov 2, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
555 Maple St., Brooklyn, NY 11203
Industry
236116 New Multifamily Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Dec 8, 2017Planned (H) · Complete scope, Safety#342820727$5,4006 viol.

Inspection #342820727

Dates

Opened
Dec 8, 2017
Closing Conference Date
Dec 8, 2017
Contested
Feb 21, 2019
Final Order
Apr 10, 2019
Closed
Oct 8, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$7,807
Penalties on Record
$5,400
Site Address
1363 Union Street, Brooklyn, NY 11213
Industry
238990 All Other Specialty Trade Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious11$3,696$2,700Feb 21, 2019Apr 10, 2019
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious13$3,696$2,700May 10, 2018Feb 21, 2019Apr 10, 2019
020011926.95
Criteria for Personal Protective Equipment (Construction)
OSHA citation code: 19260095 A
Other12$415$0May 16, 2018Feb 21, 2019Apr 10, 2019
02002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other13$0$0May 31, 2018Feb 21, 2019Apr 10, 2019
02002B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other13$0$0May 23, 2018Feb 21, 2019Apr 10, 2019
02002C1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Other13$0$0May 23, 2018Feb 21, 2019Apr 10, 2019
Nov 29, 2017Planned (H) · Partial scope, Safety#342797537$3,7002 viol.

Inspection #342797537

Dates

Opened
Nov 29, 2017
Closing Conference Date
Apr 24, 2018
Contested
Nov 27, 2018
Final Order
Apr 10, 2019
Closed
Oct 8, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$5,544
Penalties on Record
$3,700
Site Address
654 Eastern Parkway, Brooklyn, NY 11213
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious11$2,772$1,850May 4, 2018Nov 27, 2018Apr 10, 2019
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B03
Serious11$2,772$1,850May 2, 2018Nov 27, 2018Apr 10, 2019
Aug 9, 2017Planned (H) · Complete scope, Safety#342547759$4,3003 viol.

Inspection #342547759

Dates

Opened
Aug 9, 2017
Closing Conference Date
Aug 9, 2017
Final Order
Feb 23, 2018
Closed
Oct 16, 2019

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$6,652
Penalties on Record
$4,300
Site Address
115 Kingston Ave, Brooklyn, NY 11213
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 I02 I
Serious22$3,880$2,500Feb 14, 2018-Feb 23, 2018
01002A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious32$2,772$1,800Feb 16, 2018-Feb 23, 2018
01002B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious32$0$0Feb 16, 2018-Feb 23, 2018
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication3 citations · $0
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $3,650
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $4,550

Industry comparison

Violations per inspection
This employer1.8
Industry average2.1
Penalties per inspection
This employer$2,233
Industry average$2,537

Specialty Trade Contractors, 559,441 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in BROOKLYN, NY

All employers in BROOKLYN →