BOLLINGER CONSTRUCTION, INC.
FLEETWOOD SUBDIVISION, BANNISTER DRIVE, LOT #1210, FREDERICK, MD 21701 · NAICS 238130 Framing Contractors
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 17, 2025#348191396Apr 17, 2025Programmed Related (I) · Complete scope, Safety#348191396$4501 viol.1 violation$450 in penalties
Inspection #348191396
Dates
- Opened
- Apr 17, 2025
- Closing Conference Date
- May 2, 2025
- Final Order
- May 28, 2025
- Closed
- Jun 3, 2025
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 7
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $450
- Penalties on Record
- $450
- Site Address
- 5901 Old National Pike, Frederick, MD 21703
- Industry
- 238130 Framing Contractors
Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C01 I | Other | 1 | 6 | $450 | $450 | - | May 28, 2025 |
Apr 2, 2019#343908505Apr 2, 2019Planned (H) · Complete scope, Safety#343908505$7501 viol.1 violation$750 in penalties
Inspection #343908505
Dates
- Opened
- Apr 2, 2019
- Closing Conference Date
- Apr 2, 2019
- Final Order
- Jun 11, 2019
- Closed
- Jun 19, 2019
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $750
- Penalties on Record
- $750
- Site Address
- 5994 Whelan Lane Lots 184 - 191, Frederick, MD 21703
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B13 | Other | 1 | 5 | $750 | $750 | - | Jun 11, 2019 |
Sep 22, 2015#340937200Sep 22, 2015Planned (H) · Complete scope, Safety#340937200$4401 viol.1 violation$440 in penalties
Inspection #340937200
Dates
- Opened
- Sep 22, 2015
- Closing Conference Date
- Sep 22, 2015
- Final Order
- Dec 17, 2015
- Closed
- Dec 17, 2015
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $612
- Penalties on Record
- $440
- Site Address
- 5900 - 5906 Jefferson Commons Way, Frederick, MD 21701
- Industry
- 236115 New Single-Family Housing Construction (except For-Sale Builders)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01002 | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B13 | Serious | 1 | 9 | $612 | $440 | - | Dec 17, 2015 |
Sep 18, 2015#340930619Sep 18, 2015Planned (H) · Complete scope, Safety#340930619$9752 viol.2 violations$975 in penalties
Inspection #340930619
Dates
- Opened
- Sep 18, 2015
- Closing Conference Date
- Sep 25, 2015
- Final Order
- Dec 17, 2015
- Closed
- Dec 17, 2015
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $1,487
- Penalties on Record
- $975
- Site Address
- 5906 Jefferson Commons Way, Frederick, MD 21703
- Industry
- 236115 New Single-Family Housing Construction (except For-Sale Builders)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.20 General Safety and Health Provisions OSHA citation code: 19260020 B02 | Serious | 1 | 12 | $1,050 | $660 | Oct 27, 2015 | - | Dec 17, 2015 |
| 01002 | 1926.95 Criteria for Personal Protective Equipment (Construction) OSHA citation code: 19260095 A | Serious | 1 | 3 | $437 | $315 | - | Dec 17, 2015 |
Sep 3, 1999#302882881Sep 3, 1999Planned (H) · Complete scope, Safety#302882881$8506 viol.6 violations$850 in penalties
Inspection #302882881
Dates
- Opened
- Sep 3, 1999
- Closing Conference Date
- Sep 3, 1999
- Closed
- Dec 10, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 4 serious, 2 other-than-serious
- Initial Penalties
- $2,625
- Penalties on Record
- $850
- Site Address
- Fleetwood Subdivision, Bannister Drive, Lot #1210, Frederick, MD 21701
- Industry
- 238130 Framing Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.95 Criteria for Personal Protective Equipment (Construction) OSHA citation code: 19260095 A | Serious | 1 | 4 | $525 | $250 | Oct 20, 1999 | - | - |
| 02001 | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B14 | Serious | 1 | 4 | $525 | $250 | Oct 20, 1999 | - | - |
| 03001A | 1926.1051 Stairways - General Requirements (Construction) OSHA citation code: 19261051 A | Serious | 1 | 4 | $525 | $250 | Oct 20, 1999 | - | - |
| 03001B | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B01 | Serious | 1 | 4 | $0 | $0 | Oct 20, 1999 | - | - |
| 04001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Other | 1 | 3 | $1,050 | $100 | Nov 17, 1999 | - | - |
| 05001 | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B13 | Other | 1 | 4 | $0 | $0 | Oct 20, 1999 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1999 to 2025. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Specialty Trade Contractors, 558,619 employers with OSHA inspections. Arithmetic from DOL records.