Skip to content
SafetyRecord logoSafetyRecord
BRADLEY MASONRY INC
$9,580
penalties
13
viol.
9
insp.

BRADLEY MASONRY INC

5409 RAWSON LANE, PENSACOLA, FL 32503

Inspections
9
Apr 1973 to Oct 2010 · 8 safety, 1 health
Violations
13
across 9 inspections
Penalties on record
$9,580
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 1Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 29, 2010Referral (C) · Complete scope, Health#313879801$4,1654 viol.

Inspection #313879801

Dates

Opened
Oct 29, 2010
Closing Conference Date
Nov 22, 2010
Closed
Feb 16, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$5,950
Penalties on Record
$4,165
Site Address
100 "p" Street, Pensacola, FL 32501
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC70.0965 - 20.5556mg/m³
Particulates not otherwise regulated (Total Dust)22.4931 - 20.5556mg/m³
Sample WeightQC70.071 - 14.8mg
Silica, Crystalline Quartz (Respirable Fraction)50 - 34%

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.51
Sanitation (Construction)
OSHA citation code: 19260051 F03 III
Other11$2,975$2,082Jan 31, 2011--
01001B1926.51
Sanitation (Construction)
OSHA citation code: 19260051 F03 IV
Other11$0$0Jan 31, 2011--
010021926.95
Criteria for Personal Protective Equipment (Construction)
OSHA citation code: 19260095 A
Serious11$2,975$2,083Jan 31, 2011--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Other11$0$0Jan 31, 2011--
Oct 15, 2001Planned (H) · Partial scope, Safety#303986749$7001 viol.

Inspection #303986749

Dates

Opened
Oct 15, 2001
Closing Conference Date
Oct 16, 2001
Closed
Nov 26, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$700
Penalties on Record
$700
Site Address
800 E. Nine Mile Road, Pensacola, FL 32514
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious22$700$700Nov 5, 2001--
Oct 4, 2001Planned (H) · Complete scope, Safety#303986525$2,8752 viol.

Inspection #303986525

Dates

Opened
Oct 4, 2001
Closing Conference Date
Oct 5, 2001
Closed
Nov 26, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 repeat
Initial Penalties
$4,125
Penalties on Record
$2,875
Site Address
120 East Main Street, Pensacola, FL 32501
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02 I
Serious12$1,125$1,000Oct 24, 2001--
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Repeat22$3,000$1,875Oct 24, 2001--
Aug 26, 1999Referral (C) · Complete scope, Safety#302733241$7003 viol.

Inspection #302733241

Dates

Opened
Aug 26, 1999
Closing Conference Date
Aug 26, 1999
Closed
Feb 16, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$700
Penalties on Record
$700
Site Address
3012 East Cervantes Street, Pensacola, FL 32503
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious211$700$700Sep 28, 1999--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious211$0$0Sep 28, 1999--
020011926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Other44$0$0Sep 28, 1999--
Dec 15, 1993Planned (H) · Complete scope, Safety#110134871$4751 viol.

Inspection #110134871

Dates

Opened
Dec 15, 1993
Closing Conference Date
Dec 16, 1993
Closed
Feb 25, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$900
Penalties on Record
$475
Site Address
5320 N. Palafox Highway, Pensacola, FL 32503
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Serious11$900$475Jan 25, 1994--
Nov 27, 1990Unprogrammed Related (G) · Complete scope, Safety#17964636$6401 viol.

Inspection #17964636

Dates

Opened
Nov 27, 1990
Closing Conference Date
Nov 27, 1990
Closed
Jan 14, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$640
Penalties on Record
$640
Site Address
5409 Rawson Lane, Pensacola, FL 32503
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 C01
Serious66$640$640Dec 28, 1990--
Sep 12, 1975Planned (H) · Complete scope, Safety#13738208$00 viol.

Inspection #13738208

Dates

Opened
Sep 12, 1975
Closing Conference Date
Sep 12, 1975
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5041 Bayou Blvd, Pensacola, FL 32503
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 23, 1973Planned (H) · Complete scope, Safety#13737556$251 viol.

Inspection #13737556

Dates

Opened
May 23, 1973
Closing Conference Date
May 23, 1973
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
15

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$25
Penalties on Record
$25
Site Address
Riviera Condomimium, Pensacola, FL 32506
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.25
Stairways
OSHA citation code: 19100025 B
Other3-$25$25Jun 18, 1973--
Apr 11, 1973Planned (H) · Partial scope, Safety#13737101$00 viol.

Inspection #13737101

Dates

Opened
Apr 11, 1973
Closing Conference Date
Apr 11, 1973
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
45

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Regency Villas, Pensacola, FL 32505
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements6 citations · $4,750
1926.51Sanitation (Construction)2 citations · $2,082
1910.25Stairways1 citation · $25

Chemical exposure sampling

Samples
21
Substances
4
Inspections
1

Industry comparison

BLS 2024 survey: masonry contractors reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 15.2%; NAICS 23814 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source