Skip to content
SafetyRecord logoSafetyRecord
CANRON MANUFACTURING CO., INC.
$5,014
penalties
31
viol.
4
insp.

CANRON MANUFACTURING CO., INC.

3979 STATE ST., N.W., GREENTOWN, OH 44630NAICS 332618 Other Fabricated Wire Product Manufacturing

Inspections
4
Mar 1993 to Feb 2006 · 3 safety, 1 health
Violations
31
across 4 inspections
Penalties on record
$5,014
latest amounts in DOL records
By classification
Serious 27Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 24, 2006Planned (H) · Partial scope, Safety#309846368$00 viol.

Inspection #309846368

Dates

Opened
Feb 24, 2006
Closing Conference Date
Feb 28, 2006
Closed
Mar 13, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
3979 State St., N.w., Greentown, OH 44630
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 11, 2001Planned (H) · Partial scope, Safety#304481476$6005 viol.

Inspection #304481476

Dates

Opened
May 11, 2001
Closing Conference Date
May 15, 2001
Closed
Jan 25, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$600
Penalties on Record
$600
Site Address
3979 State St., N.w., Greentown, OH 44630
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious18$300$300Jun 11, 2001--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IB
Serious18$0$0Jun 4, 2001--
01001C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IC
Serious18$0$0Jun 4, 2001--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious11$300$300May 28, 2001--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other18$0$0May 24, 2001--
Mar 18, 1993Complaint (B) · Partial scope, Health#103507240$2,10010 viol.

Inspection #103507240

Dates

Opened
Mar 18, 1993
Closing Conference Date
Mar 23, 1993
Closed
Oct 12, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
19
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
8 serious, 2 other-than-serious
Initial Penalties
$2,100
Penalties on Record
$2,100
Site Address
3979 State St., N.w., Greentown, OH 44630
Industry
332618 Other Fabricated Wire Product Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30 - 0.0096mg/m³
Iron Oxide Fume30 - 0.3789mg/m³
Lead, Inorganic (as Pb)30mg/m³
Manganese Fume (as Mn)30 - 0.0189mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30 - 0.0028mg/m³

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious11$750$750Jul 30, 1993--
01002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious13$750$750May 3, 1993--
01002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious13$0$0May 31, 1993--
01002C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious13$0$0May 31, 1993--
01002D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Serious13$0$0May 31, 1993--
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious110$600$600May 31, 1993--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious110$0$0May 3, 1993--
01003C1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious110$0$0May 31, 1993--
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other119$0$0May 3, 1993--
020021904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other119$0$0May 3, 1993--
Mar 18, 1993Complaint (B) · Partial scope, Safety#103507208$2,31416 viol.

Inspection #103507208

Dates

Opened
Mar 18, 1993
Closing Conference Date
Mar 24, 1993
Closed
Oct 13, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
19
Related Activity
1 complaint

Violations and Penalties

Total Violations
16
Violation Types
15 serious, 1 other-than-serious
Initial Penalties
$3,750
Penalties on Record
$2,314
Site Address
3979 State St., N.w., Greentown, OH 44630
Industry
332618 Other Fabricated Wire Product Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious115$450$248Jul 9, 1993--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious115$0$0Jul 9, 1993--
01002A1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Serious115$450$248Apr 10, 1993--
01002B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G03
Serious115$0$0May 9, 1993--
01002C1910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Serious115$0$0Jul 9, 1993--
01002D1910.38
Emergency Action Plans
OSHA citation code: 19100038 A03 I
Serious115$0$0May 9, 1993--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Serious22$600$330Apr 9, 1993--
010061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious11$450$248May 9, 1993--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious22$450$248May 9, 1993--
01008A1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 IV
Serious14$450$248Apr 9, 1993--
01008B1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious14$0$0Apr 24, 1993--
010091910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious22$450$248Apr 9, 1993--

Showing the 12 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)5 citations · $548
1910.95Occupational Noise Exposure5 citations · $1,500
1910.157Portable Fire Extinguishers3 citations · $248

Chemical exposure sampling

Samples
39
Substances
13
Inspections
1

Industry comparison

Violations per inspection
This employer7.8
Industry average3.3
Penalties per inspection
This employer$1,254
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,875 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: spring and wire product manufacturing reported 3.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.7%; NAICS 33261 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in GREENTOWN, OH