CHAVEZ BROTHERS CONSTRUCTION, INC.

GRAYSON HILL, 711 OLD GASKINS ROAD, RICHMOND, VA 23238NAICS 238130 Framing Contractors

Inspections
1
Apr 2006 to Apr 2006 · 1 safety, 0 health
Violations
5
across 1 inspection
Penalties on record
$1,500
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 25, 2006Planned (H) · Complete scope, Safety#310049705$1,5005 viol.

Inspection #310049705

Dates

Opened
Apr 25, 2006
Closing Conference Date
Apr 28, 2006
Final Order
Aug 8, 2006
Closed
Aug 8, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$2,500
Penalties on Record
$1,500
Site Address
Grayson Hill, 711 Old Gaskins Road, Richmond, VA 23238
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious11$625$375Jun 30, 2006-Aug 8, 2006
01001B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Serious12$0$0Jun 30, 2006-Aug 8, 2006
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B10
Serious11$625$375Jun 30, 2006-Aug 8, 2006
010031926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Serious74$625$375Jun 30, 2006-Aug 8, 2006
010041926.1051
Stairways - General Requirements (Construction)
OSHA citation code: 19261051 A
Serious25$625$375Jun 30, 2006-Aug 8, 2006
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.404Electrical - Wiring Design and Protection (Construction)1 citation · $375
1926.405Electrical - Wiring Methods (Construction)1 citation · $0
1926.501Fall Protection - Duty to Have Fall Protection1 citation · $375

Industry comparison

Violations per inspection
This employer5.0
Industry average2.1
Penalties per inspection
This employer$1,500
Industry average$2,530

Specialty Trade Contractors, 551,694 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: framing contractors reported 4.6 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.8%; NAICS 23813 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in RICHMOND, VA

All employers in RICHMOND →