Skip to content
SafetyRecord logoSafetyRecord
COLSON AND COLSON GENERAL CONTRACTOR INC
$5,236
penalties
17
viol.
2
insp.

COLSON AND COLSON GENERAL CONTRACTOR INC

4350 EAST LINCOLNWAY, CHEYENNE, WY 82001NAICS 236220 Commercial and Institutional Building Construction

Inspections
2
Jan 2008 to May 2008 · 2 safety, 0 health
Violations
17
across 2 inspections
Penalties on record
$5,236
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 6

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 7, 2008Planned (H) · Complete scope, Safety#309503134$2,47312 viol.

Inspection #309503134

Dates

Opened
May 7, 2008
Closing Conference Date
May 7, 2008
Closed
Sep 25, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
100

Violations and Penalties

Total Violations
12
Violation Types
6 serious, 6 other-than-serious
Initial Penalties
$4,500
Penalties on Record
$2,473
Site Address
4350 East Lincolnway, Cheyenne, WY 82001
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A06
Serious11$1,125$787Jul 19, 2008--
01002A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B
Serious12$1,125$562May 7, 2008--
01002B1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B04 I
Serious22$0$0May 7, 2008--
01002C1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious22$0$0May 7, 2008--
010031926.701
Concrete and Masonry Construction - General Requirements
OSHA citation code: 19260701 B
Serious12$1,125$562May 7, 2008--
010041926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 II
Serious22$1,125$562May 7, 2008--
020011926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 VIII
Other12$0$0Jul 19, 2008--
020021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 E01 IV
Other12$0$0Jul 19, 2008--
020031926.1052
Stairways (Construction)
OSHA citation code: 19261052 C06
Other12$0$0Jul 19, 2008--
02004A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 A01 II
Other11$0$0Jul 19, 2008--
02004B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 A11
Other12$0$0Jul 19, 2008--
020051926.1053
Ladders (Construction)
OSHA citation code: 19261053 B16
Other11$0$0Jul 19, 2008--
Jan 30, 2008Planned (H) · Complete scope, Safety#309501542$2,7635 viol.

Inspection #309501542

Dates

Opened
Jan 30, 2008
Closing Conference Date
Jan 30, 2008
Closed
Mar 12, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$5,000
Penalties on Record
$2,763
Site Address
4350 East Lincolnway, Cheyenne, WY 82001
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.25
Housekeeping
OSHA citation code: 19260025 A
Serious11$1,250$744Jan 31, 2008--
01002A1926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 I
Serious11$1,250$744Jan 31, 2008--
01002B1926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 IV
Serious11$0$0Jan 31, 2008--
010031926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious11$1,250$531Jan 30, 2008--
010041926.1052
Stairways (Construction)
OSHA citation code: 19261052 B03
Serious11$1,250$744Jan 30, 2008--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.1053Ladders (Construction)3 citations · $0
1926.150Fire Protection (Construction)3 citations · $744
1926.501Fall Protection - Duty to Have Fall Protection3 citations · $562

Industry comparison

Violations per inspection
This employer8.5
Industry average1.5
Penalties per inspection
This employer$2,618
Industry average$1,285

Construction of Buildings, 202,638 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: nonresidential building construction reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 6.8%; NAICS 2362 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in CHEYENNE, WY

All employers in CHEYENNE →