Skip to content
SafetyRecord logoSafetyRecord
CONFER PLASTICS INC
$14,724
penalties
42
viol.
12
insp.

CONFER PLASTICS INC

101 EAST AVE, NORTH TONAWANDA, NY 14120

Inspections
12
Jul 1980 to May 2016 · 10 safety, 2 health
Violations
42
across 12 inspections
Penalties on record
$14,724
latest amounts in DOL records
By classification
Serious 18Willful 0Repeat 0Other 24

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 6, 2016Referral (C) · Partial scope, Safety#341457794$7,5943 viol.

Inspection #341457794

Dates

Opened
May 6, 2016
Closing Conference Date
May 6, 2016
Final Order
Jun 14, 2016
Closed
Jun 30, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
197
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$10,125
Penalties on Record
$7,594
Site Address
97 Witmer Road, North Tonawanda, NY 14120
Industry
326199 All Other Plastics Product Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious14$6,300$4,725Jun 13, 2016-Jun 14, 2016
010021910.335
Electrical - Safeguards
OSHA citation code: 19100335 A01 I
Serious15$3,825$2,869Jun 13, 2016-Jun 14, 2016
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IV
Other11$0$0Jun 13, 2016-Jun 14, 2016
Nov 22, 2011Planned (H) · Complete scope, Safety#316089267$00 viol.

Inspection #316089267

Dates

Opened
Nov 22, 2011
Closing Conference Date
Nov 28, 2011
Closed
Dec 5, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
200

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
97 Witmer Road, North Tonawanda, NY 14120
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 11, 2010Planned (H) · Partial scope, Safety#314441734$2,2002 viol.

Inspection #314441734

Dates

Opened
May 11, 2010
Closing Conference Date
May 11, 2010
Closed
Jul 15, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
175

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$2,200
Penalties on Record
$2,200
Site Address
97 Witmer Road, North Tonawanda, NY 14120
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious33$1,375$1,375Jun 29, 2010--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Serious44$825$825Jun 29, 2010--
Nov 30, 2006Planned (H) · Complete scope, Safety#310542295$01 viol.

Inspection #310542295

Dates

Opened
Nov 30, 2006
Closing Conference Date
Dec 4, 2006
Closed
Jan 23, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
130

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
97 Witmer Road, North Tonawanda, NY 14120
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other12$0$0Jan 23, 2007--
Mar 27, 2003Planned (H) · No Inspection scope, Safety#306334772$00 viol.

Inspection #306334772

Dates

Opened
Mar 27, 2003
Closing Conference Date
Mar 27, 2003
Closed
Mar 27, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
97 Witmer Road, North Tonawanda, NY 14120
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 26, 1998Planned (H) · Complete scope, Safety#301002606$3,43016 viol.

Inspection #301002606

Dates

Opened
Jun 26, 1998
Closing Conference Date
Aug 19, 1998
Closed
Sep 30, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
90

Violations and Penalties

Total Violations
16
Violation Types
12 serious, 4 other-than-serious
Initial Penalties
$4,900
Penalties on Record
$3,430
Site Address
River And Witmer Roads, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious11$700$490Sep 28, 1998--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IA
Serious11$875$612Sep 28, 1998--
01003A1910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J02 III
Serious11$700$490Sep 28, 1998--
01003B1910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J03
Serious11$0$0Sep 28, 1998--
01003C1910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 M01
Serious11$0$0Sep 28, 1998--

Showing the 5 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 28, 1992Complaint (B) · Partial scope, Health#108942541$1,5004 viol.

Inspection #108942541

Dates

Opened
May 28, 1992
Closing Conference Date
Aug 19, 1992
Closed
Oct 15, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
75
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$2,000
Penalties on Record
$1,500
Site Address
River And Witmer Roads, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious14$1,250$935Oct 30, 1992--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious14$750$565Sep 1, 1992--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other14$0$0Sep 1, 1992--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other14$0$0Sep 1, 1992--
Dec 8, 1988Programmed Other (K) · Complete scope, Safety#17744442$05 viol.

Inspection #17744442

Dates

Opened
Dec 8, 1988
Closing Conference Date
Dec 9, 1988
Closed
Jan 11, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
River And Witmer Roads, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Programmed Other Inspection: This inspection record is categorized as a programmed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B04
Other12$0$0Dec 20, 1988--
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 K02
Other12$0$0Dec 27, 1988--
010031910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other212$0$0Dec 27, 1988--
010041910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q05
Other12$0$0Dec 27, 1988--
010051910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other12$0$0Dec 27, 1988--
Apr 6, 1988Complaint (B) · Partial scope, Health#100806223$04 viol.

Inspection #100806223

Dates

Opened
Apr 6, 1988
Closing Conference Date
Apr 6, 1988
Closed
Apr 27, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
River And Witmer Roads, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other150$0$0Apr 14, 1988--
010021904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other150$0$0Apr 14, 1988--
010031910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 B01
Other124$0$0Apr 14, 1988--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other150$0$0May 13, 1988--
Jan 16, 1985Planned (H) · Complete scope, Safety#1009760$02 viol.

Inspection #1009760

Dates

Opened
Jan 16, 1985
Closing Conference Date
Jan 16, 1985
Closed
Dec 31, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 East Ave, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other110$0$0Feb 11, 1985--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other11$0$0Feb 22, 1985--
Inspections 1 to 10 of 12, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.37Maintenance, Safeguards, and Operational Features for Exit Routes5 citations · $0
1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $0
1910.147Control of Hazardous Energy (Lockout/Tagout)4 citations · $2,922

Other inspected employers in NORTH TONAWANDA, NY