Skip to content
SafetyRecord logoSafetyRecord
TONAWANDA NEWS
$51,462
penalties
38
viol.
9
insp.

TONAWANDA NEWS

435 RIVER ROAD, North Tonawanda, NY 14120

Inspections
9
Dec 1988 to Jan 2009 · 8 safety, 1 health
Violations
38
across 9 inspections
Penalties on record
$51,462
latest amounts in DOL records
By classification
Serious 17Willful 0Repeat 2Other 19

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 26, 2009Planned (H) · Complete scope, Safety#312835374$00 viol.

Inspection #312835374

Dates

Opened
Jan 26, 2009
Closing Conference Date
Feb 5, 2009
Closed
Feb 6, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
65

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
511110 Newspaper Publishers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 26, 2008Follow-Up (F) · Partial scope, Safety#312241441$00 viol.

Inspection #312241441

Dates

Opened
Jun 26, 2008
Closing Conference Date
Jul 16, 2008
Closed
Jul 17, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
111

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
323119

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 31, 2007Complaint (B) · Partial scope, Safety#310729181$26,0004 viol.

Inspection #310729181

Dates

Opened
Jan 31, 2007
Closing Conference Date
May 25, 2007
Contested
Jun 28, 2007
Final Order
Dec 31, 2007
Closed
Jul 17, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
111
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$57,500
Penalties on Record
$26,000
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
323119

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Other14$2,500$0Jun 19, 2007Jun 28, 2007Dec 31, 2007
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Other14$5,000$1,500Jun 19, 2007Jun 28, 2007Dec 31, 2007
020011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Repeat11$25,000$17,500Jun 19, 2007Jun 28, 2007Dec 31, 2007
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious14$25,000$7,000Jun 19, 2007Jun 28, 2007Dec 31, 2007
Nov 3, 2006Complaint (B) · Partial scope, Safety#310542022$3,4128 viol.

Inspection #310542022

Dates

Opened
Nov 3, 2006
Closing Conference Date
Nov 3, 2006
Closed
Feb 22, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
110
Related Activity
1 complaint

Violations and Penalties

Total Violations
8
Violation Types
3 serious, 5 other-than-serious
Initial Penalties
$4,875
Penalties on Record
$3,412
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
323119

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious13$1,875$1,312Feb 12, 2007--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Serious1110$1,500$1,050Dec 12, 2006--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious125$1,500$1,050Nov 15, 2006--
020011910.22
OSHA citation code: 19100022 A01
Other11$0$0Dec 12, 2006--
020021910.141
Sanitation
OSHA citation code: 19100141 D02 II
Other115$0$0Dec 12, 2006--

Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Apr 17, 2001Complaint (B) · Partial scope, Safety#304355837$20,0009 viol.

Inspection #304355837

Dates

Opened
Apr 17, 2001
Closing Conference Date
May 10, 2001
Closed
Jul 18, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
138
Related Activity
1 complaint

Violations and Penalties

Total Violations
9
Violation Types
5 serious, 1 repeat, 3 other-than-serious
Initial Penalties
$39,000
Penalties on Record
$20,000
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Serious11$5,000$0Jun 25, 2001--
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Serious33$5,000$0Jun 25, 2001--
01003A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Serious11$2,000$1,200Jun 25, 2001--
01003B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious11$0$0Jun 12, 2001--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious13$2,000$1,200Jun 25, 2001--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 19, 1999Complaint (B) · Partial scope, Safety#302863816$1,3501 viol.

Inspection #302863816

Dates

Opened
Jul 19, 1999
Closing Conference Date
Jul 19, 1999
Closed
Mar 24, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
50
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,350
Penalties on Record
$1,350
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious25$1,350$1,350Aug 15, 1999--
Apr 2, 1999Complaint (B) · Partial scope, Safety#301006383$00 viol.

Inspection #301006383

Dates

Opened
Apr 2, 1999
Closing Conference Date
Apr 2, 1999
Closed
Apr 30, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
50
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Jan 11, 1989Referral (C) · Partial scope, Health#17745969$01 viol.

Inspection #17745969

Dates

Opened
Jan 11, 1989
Closing Conference Date
Mar 24, 1989
Closed
May 1, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
89
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Propoxyethanol90 - 4.8454ppm
Qualitative Mass-Spec AnalysisQC10
Stoddard Solvent90 - 58.9816mg/m³
Xylene90 - 0.5265ppm

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other48$0$0May 3, 1989--
Dec 21, 1988Complaint (B) · Partial scope, Safety#17745209$70015 viol.

Inspection #17745209

Dates

Opened
Dec 21, 1988
Closing Conference Date
Dec 21, 1988
Contested
Jan 19, 1989
Closed
Jun 5, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
89
Related Activity
1 complaint

Violations and Penalties

Total Violations
15
Violation Types
7 serious, 8 other-than-serious
Initial Penalties
$1,050
Penalties on Record
$700
Site Address
435 River Road, North Tonawanda, NY 14120
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Enforcement Outcome

Citation contest activity appears on Jan 19, 1989. Final orders are recorded through Jun 1, 1989. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (5 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
OSHA citation code: 19100106 D02 I
Serious13$210$140Feb 24, 1989Jan 19, 1989Jun 1, 1989
01001B1910.106
OSHA citation code: 19100106 E02 II
Serious13$0$0Jan 26, 1989--
010021910.106
OSHA citation code: 19100106 E09 III
Serious13$210$140Jan 26, 1989Jan 19, 1989Jun 1, 1989
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Serious12$210$140Jan 26, 1989Jan 19, 1989Jun 1, 1989
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$210$140Feb 9, 1989Jan 19, 1989Jun 1, 1989

Showing the 5 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147The control of hazardous energy (lockout/tagout)8 citations · $39,262
1910.212General Requirements for All Machines (Machine Guarding)5 citations · $9,530
1910.1064 citations · $280

Chemical exposure sampling

Samples
28
Substances
4
Inspections
1

Other inspected employers in North Tonawanda, NY