CONSTEELCO, INC.
1625 FLOWOOD DR., JACKSON, MS 39288
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Dec 6, 2011#315306084Dec 6, 2011Planned (H) · Complete scope, Health#315306084$2,3005 viol.5 violations$2,300 in penalties
Inspection #315306084
Dates
- Opened
- Dec 6, 2011
- Closing Conference Date
- Dec 6, 2011
- Closed
- Jun 19, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $4,200
- Penalties on Record
- $2,300
- Site Address
- 1625 Flowood Dr., Jackson, MS 39288
- Industry
- 331221 Rolled Steel Shape Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling15 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 1 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 1 | 0 | mg/m³ |
| Cadmium | 1 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 1 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 1 | 0 | mg/m³ |
| Copper Fume (as Cu) | 1 | 0 | mg/m³ |
| Gravimetric DeterminationQC | 1 | 0 | mg/m³ |
| Iron Oxide Fume | 1 | 0.3949823 | mg/m³ |
| Lead, Inorganic (as Pb) | 1 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 1 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 1 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 1 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 1 | 0 | mg/m³ |
| Sample WeightQC | 1 | 0 | mg |
| Silica, Crystalline Quartz (Respirable Fraction) | 1 | 0 | % |
| Vanadium fume (as V2O5) | 1 | 0 | mg/m³ |
| Zinc Oxide Fume | 1 | 0 | mg/m³ |
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Serious | 1 | 4 | $2,400 | $1,300 | Feb 16, 2012 | - | - |
| 01001B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 1 | 4 | $0 | $0 | Jan 26, 2012 | - | - |
| 01002A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 4 | $1,800 | $1,000 | Feb 16, 2012 | - | - |
| 01002B | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Serious | 1 | 4 | $0 | $0 | Feb 16, 2012 | - | - |
| 01002C | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Serious | 1 | 4 | $0 | $0 | Feb 16, 2012 | - | - |
Jul 23, 1998#301036232Jul 23, 1998Complaint (B) · Partial scope, Health#301036232$3,85014 viol.14 violations$3,850 in penalties
Inspection #301036232
Dates
- Opened
- Jul 23, 1998
- Closing Conference Date
- Jul 24, 1998
- Closed
- Feb 8, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 30
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 12 serious, 2 other-than-serious
- Initial Penalties
- $6,750
- Penalties on Record
- $3,850
- Site Address
- 1625 Flowood Dr., Jackson, MS 39288
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (14 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Serious | 1 | 20 | $750 | $400 | Aug 19, 1998 | - | - |
| 01003A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Serious | 6 | 13 | $750 | $475 | Sep 10, 1998 | - | - |
| 01003B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 I02 I | Serious | 1 | 2 | $0 | $0 | Aug 5, 1998 | - | - |
| 01004 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D02 | Serious | 1 | 20 | $750 | $400 | Aug 19, 1998 | - | - |
| 01005 | 1910.136 Foot Protection OSHA citation code: 19100136 A | Serious | 1 | 20 | $750 | $450 | Aug 19, 1998 | - | - |
| 01006 | 1910.141 Sanitation OSHA citation code: 19100141 G02 | Serious | 1 | 1 | $750 | $300 | Aug 19, 1998 | - | - |
| 01008 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 2 | 4 | $750 | $475 | Aug 19, 1998 | - | - |
| 01009 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Serious | 1 | 2 | $750 | $475 | Aug 19, 1998 | - | - |
| 01010A | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B02 II | Serious | 1 | 4 | $750 | $400 | Aug 5, 1998 | - | - |
| 01010B | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B02 IV | Serious | 1 | 4 | $0 | $0 | Aug 5, 1998 | - | - |
| 01010C | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 III | Serious | 1 | 4 | $0 | $0 | Aug 5, 1998 | - | - |
| 01011 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 3 | 5 | $750 | $475 | Aug 5, 1998 | - | - |
| 02001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 F01 | Other | 1 | 1 | $0 | $0 | Aug 19, 1998 | - | - |
| 02002 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J02 III | Other | 1 | 2 | $0 | $0 | Aug 19, 1998 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 1998 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Industry comparison
BLS 2024 survey: rolled steel shape manufacturing reported 3.3 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.5%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source