Skip to content
SafetyRecord logoSafetyRecord
DANACOR COMPANY INC
$1,200
penalties
17
viol.
4
insp.

DANACOR COMPANY INC

33 REDFERN AVE, Inwood, NY 11696

Inspections
4
Sep 1988 to Feb 1993 · 3 safety, 1 health
Violations
17
across 4 inspections
Penalties on record
$1,200
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 24, 1993Follow-Up (F) · Partial scope, Safety#107354631$00 viol.

Inspection #107354631

Dates

Opened
Feb 24, 1993
Closing Conference Date
Feb 24, 1993
Closed
Mar 5, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
33 Redfern Ave, Inwood, NY 11696
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 5, 1992Planned (H) · Complete scope, Safety#114122807$6755 viol.

Inspection #114122807

Dates

Opened
Aug 5, 1992
Closing Conference Date
Aug 5, 1992
Closed
Feb 11, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
20

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$1,350
Penalties on Record
$675
Site Address
33 Redfern Ave, Inwood, NY 11696
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious12$450$225Dec 1, 1992--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious12$450$225Sep 23, 1992--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B02
Serious11$450$225Sep 23, 1992--
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other11$0$0Sep 25, 1992--
020021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other11$0$0Sep 25, 1992--
Oct 14, 1988Referral (C) · Partial scope, Health#100557479$2753 viol.

Inspection #100557479

Dates

Opened
Oct 14, 1988
Closing Conference Date
Oct 18, 1988
Closed
Jan 23, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
17
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$275
Penalties on Record
$275
Site Address
33 Redfern Ave, Inwood, NY 11696
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)90mg/m³
Beryllium and Beryllium Compounds (as Be)90mg/m³
Cadmium Fume (as Cd)90mg/m³
Chromium, Metal and Insoluble Salts90mg/m³
Cobalt, Metal, Dust and Fume (as Co)90mg/m³
Copper Fume (as Cu)90mg/m³
Iron Oxide Fume90 - 0.0322mg/m³
Lead, Inorganic (as Pb)90mg/m³
Manganese Fume (as Mn)90mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)90mg/m³
Nickel, Metal and Insoluble compounds (as Ni)90mg/m³
Particulates not otherwise regulated (Respirable Fraction)80mg/m³
Vanadium fume (as V2O5)90mg/m³
Zinc Oxide Fume90 - 0.0858mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
OSHA citation code: 19100037 H01
Serious113$175$175Jan 15, 1989--
010021910.132
General requirements
OSHA citation code: 19100132 A
Serious22$100$100Dec 29, 1988--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other114$0$0Dec 2, 1988--
Sep 14, 1988Planned (H) · Complete scope, Safety#102675196$2509 viol.

Inspection #102675196

Dates

Opened
Sep 14, 1988
Closing Conference Date
Sep 15, 1988
Closed
Dec 8, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
17

Violations and Penalties

Total Violations
9
Violation Types
3 serious, 6 other-than-serious
Initial Penalties
$250
Penalties on Record
$250
Site Address
33 Redfern Ave, Inwood, NY 11696
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious105$250$250Nov 14, 1988--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious42$0$0Nov 14, 1988--
01001C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious63$0$0Nov 14, 1988--
020011904.2
OSHA citation code: 19040002 A
Other217$0$0Nov 14, 1988--
020021910.37
OSHA citation code: 19100037 Q01
Other217$0$0Sep 25, 1988--
020031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other11$0$0Nov 14, 1988--
020041910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 II
Other11$0$0Nov 14, 1988--
020051910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other15$0$0Nov 14, 1988--
020061910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other15$0$0Oct 21, 1988--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus4 citations · $475
1910.215Abrasive Wheel Machinery2 citations · $0
1910.372 citations · $175

Chemical exposure sampling

Samples
125
Substances
14
Inspections
1

Other inspected employers in Inwood, NY