Skip to content
SafetyRecord logoSafetyRecord
DIVERSIFIED ENGRAVING & STAMPING MACHINE COMPANY
$573
penalties
8
viol.
1
insp.

DIVERSIFIED ENGRAVING & STAMPING MACHINE COMPANY

1100 EVANS AVENUE, Akron, OH 44305NAICS 332439 Other Metal Container Manufacturing

Inspections
1
Nov 1986 to Nov 1986 · 0 safety, 1 health
Violations
8
across 1 inspection
Penalties on record
$573
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 3, 1986Complaint (B) · Partial scope, Health#100071331$5738 viol.

Inspection #100071331

Dates

Opened
Nov 3, 1986
Closing Conference Date
Dec 19, 1986
Closed
Oct 21, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
39
Related Activity
1 complaint

Violations and Penalties

Total Violations
8
Violation Types
8 serious
Initial Penalties
$1,140
Penalties on Record
$573
Site Address
1100 Evans Avenue, Akron, OH 44305
Industry
332439 Other Metal Container Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)190mg/m³
Beryllium and Beryllium Compounds (as Be)190 - 0.0127mg/m³
Cadmium Fume (as Cd)190mg/m³
Chromium, Metal and Insoluble Salts190 - 0.0697mg/m³
Cobalt, Metal, Dust and Fume (as Co)190mg/m³
Copper Fume (as Cu)190 - 0.697mg/m³
Iron Oxide Fume190 - 2.0081mg/m³
Lead, Inorganic (as Pb)190mg/m³
Manganese Fume (as Mn)190 - 0.009mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)190 - 0.0092mg/m³
Nickel, Metal and Insoluble compounds (as Ni)190mg/m³
Particulates not otherwise regulated (Respirable Fraction)210mg/m³
Vanadium fume (as V2O5)190mg/m³
Zinc Oxide Fume190 - 0.004mg/m³

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
General requirements
OSHA citation code: 19100132 A
Serious133$360$181Apr 30, 1987--
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious11$360$181Feb 2, 1987--
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Serious11$0$0Feb 2, 1987--
01002C1910.1000
Air Contaminants
OSHA citation code: 19101000 B01
Serious11$0$0May 22, 1987--
01002D1910.1000
Air Contaminants
OSHA citation code: 19101000 B02
Serious21$0$0May 22, 1987--
01002E1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0May 22, 1987--
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 F04
Serious15$420$211Feb 23, 1987--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious15$0$0Feb 23, 1987--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1000Air Contaminants3 citations · $0
1910.134Respiratory Protection2 citations · $181
1910.1200Hazard Communication2 citations · $211

Chemical exposure sampling

Samples
268
Substances
14
Inspections
1

Industry comparison

Violations per inspection
This employer8.0
Industry average3.3
Penalties per inspection
This employer$573
Industry average$2,300

Fabricated Metal Product Manufacturing, 45,913 employers with OSHA inspections. Arithmetic from DOL records.