ELECTRICAL ENERGY SERVICES INCORPORATED
PNM SAN JUAN GENERATING STATION, FARMINGTON, NM 87499 · NAICS 237990 Other Heavy and Civil Engineering Construction
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 23, 2016#341743565Aug 23, 2016Referral (C) · Partial scope, Health#341743565$00 viol.0 violations$0 in penalties
Inspection #341743565
Dates
- Opened
- Aug 23, 2016
- Closing Conference Date
- Aug 23, 2016
- Closed
- Nov 7, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 12
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3030 La Plata Hwy, Farmington, NM 87401
- Industry
- 221118 Other Electric Power Generation
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Sep 29, 2008#312603228Sep 29, 2008Referral (C) · Partial scope, Health#312603228$00 viol.0 violations$0 in penalties
Inspection #312603228
Dates
- Opened
- Sep 29, 2008
- Closing Conference Date
- Oct 1, 2008
- Closed
- May 29, 2009
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 250
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Pnm San Juan Generating Station, Farmington, NM 87499
- Industry
- 237990 Other Heavy and Civil Engineering Construction
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling15 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 3 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 3 | 0 - 0.0032508 | mg/m³ |
| Cadmium | 3 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 3 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 3 | 0 | mg/m³ |
| Copper Fume (as Cu) | 3 | 0 - 0.5849913 | mg/m³ |
| Gravimetric DeterminationQC | 6 | 0.2497 - 1189.776 | mg/m³ |
| Iron Oxide Fume | 3 | 0 - 96.5986633 | mg/m³ |
| Lead, Inorganic (as Pb) | 3 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 3 | 0 - 0.5151577 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 3 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 3 | 0 | mg/m³ |
| Sample WeightQC | 6 | 0.075 - 548.237 | mg |
| Silica, Crystalline Cristobalite, Respirable Dust | 4 | 0 | % |
| Silica, Crystalline Quartz (Respirable Fraction) | 4 | 0 | % |
| Vanadium fume (as V2O5) | 3 | 0 - 0.2241694 | mg/m³ |
| Zinc Oxide Fume | 3 | 0 | mg/m³ |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
2 inspections, 2008 to 2016. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Chemical exposure sampling
Industry comparison
Heavy and Civil Engineering Construction, 69,142 employers with OSHA inspections. Arithmetic from DOL records.