Skip to content
SafetyRecord logoSafetyRecord
ENSIGN RIBBON BURNERS INC
$2,388
penalties
23
viol.
7
insp.

ENSIGN RIBBON BURNERS INC

101 SECOR LANE, Pelham Manor, NY 10803

Inspections
7
Sep 1976 to Apr 1997 · 6 safety, 1 health
Violations
23
across 7 inspections
Penalties on record
$2,388
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 29, 1997Planned (H) · Complete scope, Health#301454948$2,3639 viol.

Inspection #301454948

Dates

Opened
Apr 29, 1997
Closing Conference Date
May 20, 1997
Closed
Aug 18, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
9
Violation Types
6 serious, 3 other-than-serious
Initial Penalties
$3,765
Penalties on Record
$2,363
Site Address
101 Secor Lane, Pelham Manor, NY 10803
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Chromium, Metal and Insoluble Salts30 - 0.0017mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30mg/m³
Iron Oxide Fume30 - 0.071mg/m³
Lead, Inorganic (as Pb)30mg/m³
Manganese Fume (as Mn)30 - 0.000811mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30 - 0.0034mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30mg/m³

Violations

Violation list (7 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.132
General requirements
OSHA citation code: 19100132 A
Serious11$963$963Jun 25, 1997--
01001B1910.132
General requirements
OSHA citation code: 19100132 D01 I
Serious11$0$0Aug 1, 1997--
010021910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious12$701$350Jun 19, 1997--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious13$701$350Jun 19, 1997--
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious23$1,400$700Jun 19, 1997--
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious23$0$0Jun 19, 1997--
020011910.37
OSHA citation code: 19100037 Q02
Other11$0$0Jun 19, 1997--

Showing the 7 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 23, 1984Planned (H) · Records Only scope, Safety#1035005$00 viol.

Inspection #1035005

Dates

Opened
Oct 23, 1984
Closing Conference Date
Oct 23, 1984
Closed
Oct 23, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 Secor Lane, Pelham Manor, NY 10803
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 20, 1979Planned (H) · Complete scope, Safety#12105573$00 viol.

Inspection #12105573

Dates

Opened
Jun 20, 1979
Closing Conference Date
Jun 20, 1979
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1011 Secor Lane, Pelham Manor, NY 10803
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 9, 1978Follow-Up (F) · Complete scope, Safety#12093332$00 viol.

Inspection #12093332

Dates

Opened
Nov 9, 1978
Closing Conference Date
Nov 9, 1978
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 Secor Lane, Pelham Manor, NY 10803
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 22, 1978Planned (H) · Complete scope, Safety#12092607$255 viol.

Inspection #12092607

Dates

Opened
May 22, 1978
Closing Conference Date
May 23, 1978
Contested
Jun 15, 1978
Closed
Nov 22, 1978

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$90
Penalties on Record
$25
Site Address
101 Secor Lane, Pelham Manor, NY 10803
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious2-$90$25Jun 22, 1978Jun 15, 1978-
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 III
Serious1-$0$0Jun 22, 1978Jun 15, 1978-
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other2-$0$0Jun 2, 1978Jun 15, 1978-
020021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other2-$0$0Jun 15, 1978Jun 15, 1978-
020031910.309
OSHA citation code: 19100309 A 025045
Other4-$0$0Jun 2, 1978Jun 15, 1978-
Apr 5, 1977Follow-Up (F) · Complete scope, Safety#12066064$00 viol.

Inspection #12066064

Dates

Opened
Apr 5, 1977
Closing Conference Date
Apr 5, 1977
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 Secor Lane, Pelham Manor, NY 10803
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Sep 30, 1976Planned (H) · Complete scope, Safety#12070660$09 viol.

Inspection #12070660

Dates

Opened
Sep 30, 1976
Closing Conference Date
Sep 30, 1976
Contested
Oct 15, 1976
Closed
Apr 7, 1977

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$50
Penalties on Record
$0
Site Address
101 Secor Lane, Pelham Manor, NY 10803
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other1-$0$0Oct 11, 1976--
010021904.2
OSHA citation code: 19040002 A
Other1-$0$0Oct 21, 1976--
010031904.5
OSHA citation code: 19040005 A
Other1-$0$0Oct 21, 1976--
010041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 A06
Other2-$0$0Oct 21, 1976--
010051910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Other6-$0$0Oct 21, 1976--
010061910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 II
Other6-$0$0Oct 21, 1976--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other2-$50$0Oct 21, 1976--

Showing the 7 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses4 citations · $25
1910.219Mechanical Power-Transmission Apparatus4 citations · $700
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $350

Chemical exposure sampling

Samples
36
Substances
12
Inspections
1

Other inspected employers in Pelham Manor, NY

All employers in Pelham Manor →