Skip to content
SafetyRecord logoSafetyRecord
EVANS PLATING CORP
$4,508
penalties
33
viol.
4
insp.

EVANS PLATING CORP

50 WATERMAN AVE, North Providence, RI 02911

Inspections
4
Jul 1983 to Jan 2008 · 2 safety, 2 health
Violations
33
across 4 inspections
Penalties on record
$4,508
latest amounts in DOL records
By classification
Serious 18Willful 0Repeat 0Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 30, 2008Complaint (B) · Partial scope, Safety#310159298$1,3139 viol.

Inspection #310159298

Dates

Opened
Jan 30, 2008
Closing Conference Date
Feb 13, 2008
Closed
Sep 10, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 complaint

Violations and Penalties

Total Violations
9
Violation Types
9 serious
Initial Penalties
$2,625
Penalties on Record
$1,313
Site Address
50 Waterman Avenue, North Providence, RI 02911
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious11$300$150May 5, 2008--
010021910.22
OSHA citation code: 19100022 C
Serious13$300$150May 12, 2008--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious33$300$150Apr 29, 2008--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious123$300$150Sep 4, 2008--
010051910.303
OSHA citation code: 19100303 B02
Serious33$300$150Apr 29, 2008--
010061910.303
OSHA citation code: 19100303 G02 I
Serious13$525$263Apr 29, 2008--
01007A1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02 I
Serious83$300$150Apr 29, 2008--
01007B1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 E01
Serious13$0$0May 12, 2008--
010081910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 IVA
Serious53$300$150May 12, 2008--
Jan 30, 2008Complaint (B) · Partial scope, Health#310159256$3,0757 viol.

Inspection #310159256

Dates

Opened
Jan 30, 2008
Closing Conference Date
Feb 13, 2008
Closed
Dec 1, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
7 serious
Initial Penalties
$6,150
Penalties on Record
$3,075
Site Address
50 Waterman Avenue, North Providence, RI 02911
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Chromic Acid and Chromates (as CrO3)20 - 0.000341mg/m³
Chromium (VI) - TWA20 - 0.000177mg/m³

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q01
Serious113$750$375Jul 26, 2008--
010021910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q06 IIIA
Serious11$750$375Jul 26, 2008--
010031910.132
General requirements
OSHA citation code: 19100132 D01 I
Serious11$1,050$525Jul 11, 2008--
010041910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious12$750$375Jul 16, 2008--
010051910.151
Medical Services and First Aid
OSHA citation code: 19100151 B
Serious113$750$375Jul 14, 2008--
010061910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious113$1,050$525Jul 11, 2008--
010071910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious64$1,050$525Aug 1, 2008--
Aug 30, 1985Planned (H) · Complete scope, Health#929992$605 viol.

Inspection #929992

Dates

Opened
Aug 30, 1985
Closing Conference Date
Oct 22, 1985
Closed
Dec 20, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 4 other-than-serious
Initial Penalties
$60
Penalties on Record
$60
Site Address
50 Waterman Ave., North Providence, RI 02911
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$60$60Dec 31, 1985--
020011904.2
OSHA citation code: 19040002 A
Other120$0$0Dec 12, 1985--
020021910.23
OSHA citation code: 19100023 A08
Other15$0$0Dec 23, 1985--
020031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Other12$0$0Dec 23, 1985--
020041910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 III
Other12$0$0Dec 12, 1985--
Jul 25, 1983Planned (H) · Complete scope, Safety#10268464$6012 viol.

Inspection #10268464

Dates

Opened
Jul 25, 1983
Closing Conference Date
Jul 26, 1983
Closed
Oct 14, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
12
Violation Types
1 serious, 11 other-than-serious
Initial Penalties
$60
Penalties on Record
$60
Site Address
50 Waterman Ave, North Providence, RI 02911
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A04
Serious7-$60$60Oct 10, 1983--
020011904.2
OSHA citation code: 19040002 A
Other1-$0$0Sep 9, 1983--
020021910.36
OSHA citation code: 19100036 B04
Other1-$0$0Aug 11, 1983--
020031910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Other1-$0$0Aug 22, 1983--
020041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other1-$0$0Aug 25, 1983--
020051910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other1-$0$0Sep 9, 1983--
020061910.176
Handling Materials - General
OSHA citation code: 19100176 C
Other1-$0$0Aug 30, 1983--
020071910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other1-$0$0Sep 9, 1983--
020081910.303
OSHA citation code: 19100303 F
Other8-$0$0Aug 11, 1983--
02009A1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other1-$0$0Aug 25, 1983--
02009B1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other3-$0$0Aug 25, 1983--
020101910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 III
Other1-$0$0Aug 11, 1983--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Wiring methods, components, and equipment for general use7 citations · $300
1910.212General Requirements for All Machines (Machine Guarding)3 citations · $585
1910.3033 citations · $413

Chemical exposure sampling

Samples
4
Substances
2
Inspections
1

Industry comparison

BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in North Providence, RI

All employers in North Providence →